Download Print this page

Eclipse Security ECL-ACC997 Manual

Advertisement

Quick Links

Contents
1
Product
or
ECL-ACC997
ECL-ACC999
Installation
4
2
3
5
External WG keyboard
※ If you want to program system on controller directly, please order WG keyboard then install it according to the following pattern.
1
Connector Table
P4
P6
P5
P7
Cable:
P1
Wire Application Wire
Color
1
Blue White (N.O.)DC24V1Amp
Lock Relay
2
Purple White (N.C.)DC24V1Amp
3
White
Common-COM-Point
Door Contact
4
Orange
Exit Switch
5
Purple
Alarm Relay
6
Gray
7
Thick Red DC 12V
Power
8
Thick Black DC 0V
Cable:
P2
Wire Application Wire
Color
Beeper
1
Pink
2
Yellow
LED
3
Brown
Door Output
4
Blue White
5
Thin Green Wiegand DAT: 0 Input
Wiegand
6
Thin Blue Wiegand DAT: 1 Input
WG Door Contact
7
Orange
WG Exit Switch
8
Purple
ECL-ACC997 / ECL-ACC999
2
3
Optional
User Guide
WG
keyboard
Digital Relay
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Connect the terminal cables to the body and attach the body to the mounting plate.
1
Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
2
3
P3
P2
P1
Description
(COM)DC24V1Amp
Negative Trigger Input
Negative Trigger Input
Transistor Output Max. 12V/100mA
(Open Collector Active Low)
Description
Beeper Output 5V/100mA, Low
Red LED Output 5V/20mA, Max
Green LED Output 5V/20mA, Max
Transistor Output Max. 12V/100mA
(Open Collector Active Low)
Negative Trigger Input
Negative Trigger Input
4
Terminal Cables
P1
P4
P5
P6
P7
only provide to the controller that have doorbell function.
Remove the Protection plug that in the bottom left.
(※ Do not lose protection plug or it will affect the protection level.)
WG Keyboard cable will be connected to the pin board.
WG Keyboard connected to the controller from the bottom left of the hole.
When you finish programming system, please put protection plug back
to the controller.
Cable:
P3
Wire Application Wire
TCP/IP Output
Cable:
P4
Wire Application Wire
RS-485 for Lift
Controller
Cable:
P5
Wire Application Wire
Anti-Tamper
Switch
Cable:
P6
Wire Application Wire
Power
Security trigger signal
Arming
Duress
Cable:
P7
(For the controller that doorbell function.)
Wire Application Wire
Doorbell
5
Tools
Flat Head Cap Philips
Tapping Screw: 4x20
P2
P3
Security Torx: M3x10
Security Torx Wrenches
P7
Protection Plug
Color
Description
1
---
---
2
---
---
3
Orange White Net - TX+
4
Orange
Net - TX-
5
Green White Net - RX+
6
Gerrn
Net - RX-
7
---
---
Color
Description
1
Thick Green RS-485(B-)
2
Thick Blue RS-485(A+)
Color
Description
1
Red
N.C.
2
Orange
COM
3
Yellow
N.O.
Color
Description
1
Red
DC 12V Output
2
Purple
Security trigger signal Output
3
Red White Arming Output
4
Yellow White Duress Output
Color
Description
Transistor Output Max. 12V/100mA
1
Black White
(Open Collector Active Low)
2
Black
GND
V121203

Advertisement

loading

Summary of Contents for Eclipse Security ECL-ACC997

  • Page 1 ECL-ACC997 / ECL-ACC999 V121203 Contents Product Optional User Guide Terminal Cables Tools Flat Head Cap Philips Tapping Screw: 4x20 keyboard Security Torx: M3x10 Security Torx Wrenches ※ Digital Relay ECL-ACC997 ECL-ACC999 Protection Plug only provide to the controller that have doorbell function.
  • Page 2: Wiring Diagram

    POWER 12VDC 12VDC ECL-ACC997 / ECL-ACC999 become WG mode (28 016 ) 1. When ECL-ACC997 / ECL-ACC999 become WG mode,it can be used with any controllers. (BZ IN) RLED (RLED IN) 2. ECL-ACC997 / ECL-ACC999 support Anti-pass-back by finger or card.
  • Page 3 NN: 16 sets of auto-open zone (NN=00~15); HHMMhhmm=Starting time to ending time; 7123456H= 7 days of week + Holiday (F= 0: disable; 1: enable)] [e.g.] ECL-ACC997 / ACL-ACC999 (without WG reader), to set second time zone which could be passed only at 9:30am to 4:20pm on Mon and Fri.
  • Page 4 → Input 4 digits code → arming code → arming code → arming code → ※ Factory default armingcode is: 1234. U=Reader unit (0=ECL-ACC997 / ECl-ACC999, 1=WG Reader). G. Adding / Deleting Fingerprint or Finger-Vein Adding Access programming mode → UUUUU Place your finger on the sensor [F=1= Adding 1 Finger data;...
  • Page 5: Restoring Factory Settings

    3. Extra WG keypad panel is needed for adding card or downloading data connected to PC. 4. Each finger need to be collected 3 times enrolling for ECL-ACC997 / Each finger need to be collected 1 times enrolling for ECL-ACC999.
  • Page 6 Ethernet Module Show which computer is linking on Ethernet Module. Current IP address of the ECL-ACC997 / ECL-ACC999 Log-in User Password When you choose the "Networking Setting" or "User Password" at first. Log-in window will pop out and please input ※...
  • Page 7 PPPPPP: Master Code, (Default value: 123456) Entering programming mode PPPPPP Exiting programming mode Exiting programming mode and enabling all device Including ECL-ACC997 / ECL-ACC999, WG Reader into arming status. Enabling each device into arming status. U=Enable target unit (0=ECL-ACC997/ECL-ACC999,1=WG Reader) NNN=Node ID,(001~254)
  • Page 8: Function Default Value

    Biometrics Device Access controller Fingerprint & Finger Vein V121203 Command List (By W G K e y b o a r d ) Function Command Exposition SSSSS= starting user address; EEEEE= ending user address Anti-pass-back (Enable user) SSSSS EEEEE P=0=Enable; P=1=Disable; P=2=Initial Lift control setting: single door UUUUU UUUUU=user address;LL :Floor number(01~64 floor)

This manual is also suitable for: