300 g IP40 Protection class Storage Storage temperature -10 … 70 °C Storage relative humidity 0 … 95 % RH Model Up to XI.2010 the device MS8326 is manufactured under the name MS8203U2-6. From version V3.11 there is start by level.
Page 3
11-14V Fig.2.4 Outputs Wiring diagram III. DESIGNATION The MS8326 device is organized as two timer blocks, operating independently or interconnected. Both timers can work in the modes:999 min; 999 s; 999 s.10 ;999 s.10 Each timer counts two times - time tLo, and time tHi, and for each of them the user sets a group of outputs to be active.When an output is connected to both timer modules, "OR"...
Page 4
OPERATING GUIDE When the supply voltage is applied, the timers are ready for operation, and the current values before the power supply is stopped are displayed. In case these are unfinished jobs, the corresponding LED on the front panel flashes, and if the timer was not active when the power supply fails, the display shows the setting tLo, the LEDs for this timer are off.
Page 5
External start ; RESET t1Lo t1Hi Start from G r o Gr o u p keyboard. t 1 L 0 t 1 H i Timer 1 Restart Restart t2Lo t2Hi Timer 2 External start ; G ro u p G ro u p t 2 L t 2 H i Start from...
Page 6
RESET ON BOTH TIMERS FROM THE KEYBOARD RESET can be applied to both timers by pressing buttons simultaneously: On display: [- - -] [- - -] V. EDIT OF SETTINGS In this mode, the timer operation mode, start mode and internal restart permission are set. Entering this mode is done by pressing and holding for more than 5 seconds simultaneously on the buttons The following symbols appear on the display:...
Page 7
Para- Description Value meters Timer output type 0 – without restarting the other timer О 1 - restart the other timer after the end of tHi. Start mode, behavior after Without automatic completion Automatically complete the job POWER ON of the job after power supply after power is applied Start by front.
Page 8
RECOMMENDATION AGAINST EMI (Electromagnetic Interference) Recommendations for use of connecting wires ✔ For longer distances for lines subjected to electromagnetic interference, it is desirable to use a twisted pair wire. ✔ For better noise protection, a shielded cable may be used, which must be grounded at only one end.
Servi Date Orde Type of repairs done ed out the of receipt r number transmissio repair Seller:....Buyer:....4, Murgash str., Plovdiv city, Bulgaria, 4000 Тел.: (+359 32) 642 519, 640 446 факс: (+359 32) 640 446 www.microsyst.net e-mail: info@microsyst.net...