Expert Power Control 1104
Expert Power Control 1105
© 2022 GUDE Systems GmbH
Manual Ver. 1.3.1
from Firmware Ver. 1.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Expert Power Control 1104 and is the answer not in the manual?

Questions and answers

Summary of Contents for GÜDE Expert Power Control 1104

  • Page 1 Manual Expert Power Control 1104 Expert Power Control 1105 © 2022 GUDE Systems GmbH Manual Ver. 1.3.1 from Firmware Ver. 1.3...
  • Page 2 Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 3: Table Of Contents

    3.4.1 NTP ......................... 37 3.4.2 Timer ........................38 3.4.3 Timer Configuration ....................38 Sensors .......................... 45 3.5.1 Port Switching ......................46 E-Mail ..........................47 Specifications Automated Access ....................... 50 Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 4 Sensor Tables ......................90 4.10 MQTT ..........................91 4.10.1 Example HiveMQ ....................93 Support Data Security ........................ 96 Contact .......................... 96 Declaration of Conformity ..................97 FAQ ..........................97 Index Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 5 Device Description...
  • Page 6: Device Description Security Advice

    · Expert Power Control 1104 / 1105 · Quick Start Guide Description The Expert Power Control 1104 / 11105 can switch one different load output. The device has the following features: · One Power Port switchable directly on the device, via HTTP(S), SNMP ·...
  • Page 7: Installation

    · Firmware update during operation via Ethernet possible · Encrypted e-mails (SSL, STARTTLS) · Access protection through IP access control · Low own consumption · Developed and produced in Germany Installation Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 8: Technical Specifications

    · Storage temperature -20°C - 70 °C · Humidity 0% - 95% (non-condensing) Case Synthetic Measurements 484mm x 46mm x 74mm (L x H x W) Weight approx. 1050 kg Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 9: Electrical Measurement

    (total) Active Energy 9.999.999,999 0.001 < 1.5% (resettable) Sensor One external sensor can be connected to the Expert Power Control 1104 / 1105. The following sensors are currently available Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 10 The sensor is automatically detected after connect. This is indicated by the green LED The sensor values are displayed at the "Con- on the sensor port that is lit permanently. trol Panel" web page: Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 11 A click on the link in the "Name" column opens the display of the Min and Max values. The values in a column can be reset using the "Reset" button. The "Reset" button in the name column deletes all stored Min and Max values. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 12: Operating

    Operating...
  • Page 13: Operating The Device Directly

    The web page provides an overview of the switching state, energy measurement values (only EPC 1105), as well as the external sensor, provided that it is connected. When the port is clicked at the Expert Power Control 1104 / 1105, a panel with buttons to con- trol the port appear: Expert Power Control 1104 / 1105 ©...
  • Page 14: Maintenance

    Maintenance in the web interface The following functions are available from the maintenance web page: · Firmware Update · Change the SSL certificate · Load and save the configuration Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 15 The GBL_Conf.exe program is available free of charge on our website www.gude.info and can also be found on the enclosed CD-ROM. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 16 Bootloader mode (see chapter Bootloader activation ). All TCP/IP settings are reset in this operation. If a unit is set to factory defaults, an uploaded certificate or updated firmware will be preserved. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 17: Maintenance Page

    A jump to the boot loader or a restart of the device lead by no means to a change of the relay states. Restore Fab Settings and Restart Device: Performs a restart and resets the device to factory default Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 18: Configuration Management

    "" #len: 0..100 The command "system fabsettings" from the beginning of a generated configuration file brings the device into the factory state, and then executes the individual commands that Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 19: Bootloader Activation

    2) or · Remove the power supply · Hold down the "Select" button. If the push button is recessed, use a pin or paper clip · Connect the operating voltage Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 20 If a unit is set to factory defaults, an uploaded certificate or updated firmware will be preserved. 1) via push button: · Activate the Bootloader Mode of the device Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 21 · In menu "Program Device" activate the item "Reset to Fab Settings" · The status LED will blink in a fast rhythm, please wait until the LED blinks slowly (about 5 seconds) Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 22: Configuration

    Configuration...
  • Page 23: Power Ports

    Initialization delay: Here can be configured how long the port should wait to switch to its defined state after the device is turned on. The delay may last up to 8191 seconds. This Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 24: Watchdog

    You can monitor devices on your own network, as well as devices on an external net- work, e.g. the operating status of a router. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 25: Ethernet

    If this option is activated, a watchdog is also triggered if the Ethernet link is down. Ethernet Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 26: Ip Address

    Use IPv6 Router Advertisement: The Router Advertisement communicates with the router to make global IPv6 addresses available. Use DHCP v6: Requests from an existing DHCPv6 server addresses of the configured Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 27: Ip Acl

    The input fields for the manual setting of IPv6 addresses allow you to configure the prefix of four additional IPv6 device addresses, and to set two DNS addresses, and a gateway. 3.2.2 IP ACL Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 28 If you choose a wrong IP ACL setting and locked yourself out, please activate the Bootloader Mode and use GBL_Conf.exe to deactivate the IP ACL. Alternatively, you can reset the device to factory default. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 29: Http

    Users can log in by entering the user password in order to query the status information and initiate switching operations. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 30: Protocols

    SHA2-256 hash. If you want to change a password, the complete password must always be re-entered. If you have forgotten your password, please activate the bootloader mode and then turn off the password prompt in GBL_Conf.exe. Protocols 3.3.1 Console Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 31: Syslog

    Enable Syslog: Enables the usage of Syslog Messages. Syslog Server: If you have enabled Syslog Messages, enter the IP address of the server to which the syslog information should be transmitted. 3.3.3 SNMP Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 32 SNMP v2. Accesses to SNMP v2 are always insecure. Community public: The community password for SNMP GET requests. Community private: The community password for SNMP SET requests. Enable SNMP v3: Activates SNMP v3. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 33: Radius

    MIB table: The download link to the text file with the MIB table for the device. More information about SNMP settings are available from our support or can be found on the Internet at www.gude.info/wiki. 3.3.4 Radius Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 34 Shared secret: Radius Shared Secret. For compatibility reasons, only use ASCII charac- ters. Timeout: How long (in seconds) will be waited for a response from an Authentication Request. Retries: How often an authentication request is repeated after a timeout. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 35: Modbus Tcp

    Password is accepted by the configured Radius Servers. 3.3.5 Modbus TCP Enable Modbus TCP: Enables Modbus TCP support. Modus TCP port: The TCP/IP port number for Modbus TCP. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 36: Mqtt

    [mac] and [host] symbolize the MAC address or the hostname of the device. Permit CLI commands: Enables the execution of console commands. Publish device data summary interval: Time interval in which messages with the global status of the device are sent. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 37: Clock

    Primary NTP server: IP address of the first NTP server. Backup NTP server: IP address of the second NTP server. Used when the first NTP server does not respond. Timezone: The set time zone for the local time. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 38: Timer

    This instruction chapter applies to all Gude devices. For devices without switchable ports you can only create a complex timer. For an action there is only the register "Ac- tion CLI" available, and not the register "Action PortSwitch". Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 39 "Save" saves this rule. We have now created 2 rules, one for when the port is turned on and the second for when it is turned off. Creating a complex timer Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 40 Ports are switched as action mode, alternatively a console command (CLI Cmd) can be executed. After changes to existing timers, the "Rule Name" may no longer be meaningful. To keep the overview, it may be useful to adjust the name. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 41 9:30 and 17:10 in a single timer rule. You need a second rule for this. If you set the hours 9 and 17, as well as the minutes 10 and 30, then the four times 9:10, 9:30, Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 42 In this example, port 1 and port 5 are enabled and disabled after 90 minutes by batch mode. A popup on the mouse pointer shows the port number of the field. Console Commands Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 43 Switch port 3 on every day at 9:25, and off again at 17:30. You save. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 44 The jitter of 1800 seconds means that the action is executed randomly in a period between 30 minutes before and 30 minutes after the programmed time. The probability (Random Trigger Probability) of execution here is 100%. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 45: Sensors

    Min/Max measurement period: Selects the time range for the sensor min/max values on the overview web page. Hysteresis Example: Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 46: Port Switching

    Example with "Maximum value" of 65 °C, "Minimum value" of 25 °C and hysteresis of 3 ° C. The dotted line shows the hysteresis. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 47: E-Mail

    "On" or "Off" action is defined for a port, the port can never reach this state by ex- ceeding sensor values. Unless it is the initial state. E-Mail Enable E-Mail: Activates the E-Mail dispatch of messages. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 48 If you want to change a password, the complete password must always be re-entered. E-Mail Logs: Logging of E-Mail system messages. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 49: Specifications

    Specifications...
  • Page 50: Automated Access

    JSON format. The structure of the CGI commands and the JSON data is explained in more detail in our Wiki article: http://wiki.gude.info/EPC_HTTP_Interface Messages Depending on adjustable events, various messages can be sent from the device. The fol- Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 51 Global Device started Switch port Port watchdog status Syslog switched on/off MQTT connection established MQTT connection lost Value-Threshold external sensors Current Time-Interval external sensors Current Value-Delta external sensors Current Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 52: Ip Acl

    PCs, the device is not completely transparent. Due to technical restraints, a TCP/IP connection will be accepted at first, but then rejected directly. Examples: Entry in the IP ACL Meaning 192.168.0.123 the PC with IP Address "192.168.0.123" can access the device Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 53: Ipv6

    If the local password and RADIUS are enabled at the same time, the system is first checking locally, and then in the event of a failure the Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 54: Snmp

    (subtree name). The device's MIB table can be displayed as a text file by clicking on the link "MIB table" on the SNMP configuration page in the browser. SNMP v1 and v2c Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 55 Otherwise the device could be accessed with it. · If only authentication is used, then the new "HMAC-SHA-2" methods are superior to the MD5 or SHA-1 hashing algorithms. Since only SHA-256 is accelerated in hard- Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 56 NET-SNMP Examples Query Power Port 1 switching state: snmpget -v2c -mALL -c public 192.168.1.232 epc822XPortState.1 Switch on Power Port 1: snmpset -v2c -mALL -c private 192.168.1.232 epc822XPortState.1 integer 1 Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 57: Device Mib 1104

    Integer32 actual air pressure epc1104Dew Point .68.1.6.1.1.6.x Integer32 dew point for actual temperature and humidity epc1104Dew PointDiff .68.1.6.1.1.7.x Integer32 difference betw een dew point and actual temperature (Temp - Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 58: Device Mib 1105

    .69.1.5.1.2.1.5.x Unsigned32 Actual Curent on Pow er Channel. epc1105Voltage .69.1.5.1.2.1.6.x Unsigned32 Actual Voltage on Pow er Channel epc1105Frequency .69.1.5.1.2.1.7.x Unsigned32 Frequency of Pow er Channel epc1105Pow erFactor .69.1.5.1.2.1.8.x Integer32 Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 59 PointDiff .69.1.6.1.1.7.x Integer32 difference betw een dew point and actual temperature (Temp - Dew Point) epc1105ExtSensorName .69.1.6.1.1.32.x OCTETS A textual string containing name of a external Sensor Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 60: Ssl

    -x509 -days 365 -key server.key -in server.csr -out server.crt The server keys should be created with "openssl genrsa". The Gude device pro- cesses keys in the traditional PKCS#1 format. This can be recognized by the fact that Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 61: Console

    Raw Mode a simple TCP/IP connection is sufficient to send commands. The communication can also be performed automated (e.g. via scripting languages). The console features are configured through the web interface Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 62 0 and 5 can be set. In the help, this can be recognized by the fact that the values are not separated by the "|" character, but by commas. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 63 Telnet server will be returned. Normally the client begins with the IAC negotiation. If this is not the case with the client, the device configuration "Active negotiation" should be turned on. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 64 In this example these are the fields Absolute Active Energy (0), Power Active (1), Voltage (2), Current (3) and Reset Time Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 65: Ssh

    The "login" must be enabled for SSH. Users and passwords can be stored locally or retrieved via a radius server. If you want to use SSH in a terminal, Activ- ate echo should be enabled. Public Keys Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 66 -t ecdsa -b 384 -f ssh.key In the file ssh.pub is then the private key, the content of ssh.key.pub is inserted into the field "Upload SSH public key:". Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 67: Console Cmd 1104

    {OFF=0|ON=1} enables SSH console ssh enabled show show s if SSH enabled console ssh port set {ip_port} sets SSH port console ssh port show show s SSH port Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 68 {port_num} {sen_type} {sen_field} sets minimum value for sensor minval set {num} extsensor {port_num} {sen_type} {sen_field} show s minimum value for sensor minval show Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 69 "{passw d}" sets hashed http admin passw ord enters cmd group "ip4" ip4 hostname set "{name}" sets device hostname ip4 hostname show show s device hostname Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 70 {broker_idx} keepalive set {num_secs} sets keep-alive time mqtt {broker_idx} keepalive show show s keep-alive time mqtt {broker_idx} topic set "{name}" sets topic prefix mqtt {broker_idx} topic show shw os topic prefix Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 71 "radius" radius {PRIMARY=0|SECONDARY=1} enabled set enables radius client <off=0/on=1> radius {PRIMARY=0|SECONDARY=1} enabled show if radius client enabled show radius {PRIMARY=0|SECONDARY=1} server set sets radius server address "<dns_name>" Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 72 SNMP trap receiver snmp trap receiver {trap_num} show {trap_num} syslog enters cmd group "syslog" syslog enabled set {OFF=0|ON=1} enables syslog msgs on/off syslog enabled show show if syslog enabled Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 73 {rule_num} action hash set "{data}" sets action binary form timer {rule_num} action hash show show s action binary form timer {rule_num} delete delete one timer timer delete all delete all timer Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 74 Constants "{7x01=0|7x04=0|7x02=1|7x05=1|7x06=2}" Index Description Products Temperature 7001, 7101, 7201 Temperature 7004, 7104, 7204 Temperature, Humidity 7002, 7102, 7202 Temperature, Humidity 7005, 7105, 7205 Temperature, Humidity, Air Pressure 7006, 7106, 7206 Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 75: Console Cmd 1105

    {OFF=0|ON=1} enables temporary push msgs console telnet pushmsgs show show s if temporary push msgs are enabled console telnet user set "{username}" sets login user name Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 76 {port_num} {sen_type} {sen_field} events type set "{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E enables different event types VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5,E VT_DISPLAY=6,EVT_CONSOLE=7,EVT_MQTT=8} " extsensor {port_num} {sen_type} {sen_field} show s w hat event types are enabled events type show Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 77 {OFF=0|ON=1} enables login for RADIUS on/off http passw d radius show show s if RADIUS login enabled Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 78 {line_num} {energy_sensor} events enables events on/off set {OFF=0|ON=1} linesensor {line_num} {energy_sensor} events show s if events are enabled show linesensor {line_num} {energy_sensor} events type set enables different event types "{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5}" Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 79 LEGACY - show s Port for Pow er Port Sw itching ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3} port actions show linesensor {line_num} {BELOWMIN=0| LEGACY - sets Port state for Pow er Port ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3} Sw itching actions Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 80 {port_num} repow erdelay show show s port repow er delay port {port_num} resettime set {num} sets port reset duration port {port_num} resettime show show s port reset duration Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 81 SNMP SET cmds are enabled snmp snmpv2 enabled set {OFF=0|ON=1} enables SNMP v2 on/off snmp snmpv2 enabled show show if SNMP v2 is enabled Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 82 {0..23} sets facility level for timer syslog timer syslog facility show show s facility level for timer syslog Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 83 6. Please see the External Type and External Sensor Field Tables for the correct sensor index Energy Sensor Table "{energy_sensor}" Index Description Unit Forward Active Energy Power Active Voltage Current Frequency 0.01 hz Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 84: Modbus Tcp

    Please try both possibilities for tests! If Modbus TCP is activated in the configuration, the ports (relays, outputs, eFuses) can be switched and the following data is callable: Address range overview: Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 85 Write Holding Register 0x06 Write Multiple Holding Registers 0x10 Read Device Identification 0x2B / 0x0E Coils Device Resource Start Device Function Power/Output/eFuse 0x000 0x3ff Coil represens Port State Discrete Inputs Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 86 32-bit (signed) Port Energy Sensors 0x8200 to 0x823f 16-bit (signed) Bank Energy Sensors 0x8240 to 0x827f 16-bit (signed) Power Source Energy Sensors 0x8280 to 0x82cf 16-bit (signed) Residual Current Monitor Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 87 For devices with only one phase, the phase is set to zero in the formula. Examples: "Power Active" for 1st line sensor and 3rd phase: 0x400 + 0 * 0x120 + 2 * 0x60 + 1 * 2 = 0x4C2 Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 88 Power Source: 0x8240 + PowerSrc * 2 + Offset Examples: "Voltage" at third bank: 0x8200 + 2 * 2 + 0 = 0x8204 "Current" at first PowerSrc: 0x8240 + 0 * 2 + 1 = 0x8241 Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 89 1 Byte 0x2b MEI Type 1 Byte 0x0e Read Dev ID code 1 Byte 0x01 Object Id 1 Byte 0x00 Response Code 1 Byte 0x2b MEI Type 1 Byte 0x0e Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 90: Sensor Tables

    Power Angle 0x40c Power Apparent 0x40e Power Reactive 0x410 Absolute Active Energy Resettable 0x412 Absolute Reactive Energy 0x414 Absolute Reactive Energy Resettable 0x416 Reset Time - sec. since Reset 0x418 Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 91: 4.10 Mqtt

    "[host]", which contains the host name. An example topic for a switching message of the second port would then be: "de/gudesystems/epc/00:19:32:01:16:41/switch/2". Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 92 JSON object and sent periodically in a configurable time interval. This summary de- pends on the properties of the device and the connected sensors, and could look like this: Topic: en/gudesystems/epc/00:19:32:01:16:41/device/telemetry Message: "type": "telemetry", Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 93: Example Hivemq

    "unit": "deg C" }, { "field": "dew_diff", "v": 5.3, "unit": "deg C" "ts": 210520 4.10.1 Example HiveMQ What does an MQTT configuration look like using HiveMQ as an example? Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 94 In the MQTT configuration of the Gude device, transfer the hostname of the HiveMQ broker, as well as username and password. Additionally activate TLS and set the correct port. Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 95: Support

    Support...
  • Page 96: Data Security

    · If possible, place the device behind a firewall. Contact GUDE Systems GmbH Von-der-Wettern-Straße 23 51149 Cologne Germany Phone: +49-221-912 90 97 Fax: +49-221-912 90 98 E-Mail: mail@gude.info Internet: www.gude.info shop.gude.info Managing Director: Dr.-Ing. Michael Gude Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 97: Declaration Of Conformity

    Value added tax identification number (VAT): DE 122778228 Declaration of Conformity This product from the Expert Power Control 1104 / 1105 series is in conformity with the European directives for CE marking applicable to this product. The complete CE de- claration of conformity for this product can be found on the website www.gude.info in the...
  • Page 98 9. Disable switching events · You can set the sending of syslog, emails etc. when switching ports (only concerns Gude devices with relays) under "System" in the sensor configuration Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 99: Index

    - G - - S - GBL_Conf.exe Security Advice Select button - H - Sensors 9, 45 SNMP 31, 54 HTTP HTTPS Start-up the device Status LED Status-LED syslog Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 100 Index - T - Technical Specifications Timer Timer Configuration - W - Watchdog Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...
  • Page 101 Expert Pow er Control 1104 / 1105 © 2022 GUDE Systems GmbH 3/16/2022 Expert Power Control 1104 / 1105 © 2022 GUDE Systems GmbH...