Download Print this page

Optex OAM-DUAL T Operation Manual page 2

Advertisement

ADJUSTMENTS
1
Area depth angle adjustment
Depth angle
adjustment screw
When adjusting the 2nd row close to the door,
follow Table 2 dipswitch16 for the easier adjustment.
Make sure that the detection area does not overlap with the door / header, and there is no highly reflecting
NOTE
object near the detection area otherwise ghosting / signal saturation may occur.
1-1 AIR adjustment
Depth angle adjustment screw
Shallow
Deep
for the AIR area
Red
Use the area adjustment tool (A) as shown above
to change the area depth angle.
For the easier adjustment, see REFERENCE.
[mm(feet,inch)]
[mm(feet,inch)]
0
0
Deep
Shallow
2000
2000
(6'6")
(6'6")
3000
3000
(9'10")
(9'10")
0
2000
2000
1000
1000
(6'6")
(3'3")
(6'6")
(3'3")
2
Area width adjustment
2-1 AIR adjustment
To adjust the AIR detection area width, use the
adjustment screws as shown in the picture below.
1 2 3
10 11 12
Eliminated
Eliminated
Eliminated
Eliminated
Narrow
Wide
Width adjustment screws
NOTE
When setting the detection area width, make sure to turn
the adjustment screws until it clicks.
cannot be eliminated separately, neither can
1 2 3
10 11 12
[mm(feet,inch)]
Front view
0
2000
(6'6")
1
2
3
4 5
6
7
8
9 10 11 12
3000
(9'10")
2000
0
2000
1000
1000
(6'6")
(6'6")
(3'3")
(3'3")
Dipswitch settings
4
After changing the dipswitch settings, make sure to push the function
switch for 2 seconds.
Table 2
AIR settings
Microwave settings
Other settings
Function
Setting
Dipswitch
Middle
Low
1
Sensitivity
Dipswitch
1
2
1
2
2
2.0 to 3.0m 2.0 to 3.0m 2.5 to 3.2m 3.0 to 3.5m
Dipswitch
30sec
60sec
3
Presence timer
Dipswitch
3
4
3
4
4
Dipswitch
Setting1
Setting2
5
Frequency
Dipswitch
5
6
6
5
6
High
Low
Safety / Testoutput
Dipswitch
7
(to the door controller)
7
7
High
Low
Test input
Dipswitch
8
(from the door controller)
8
8
Bi
Uni
Dipswitch
Direction
9
9
9
OFF
ON
Dipswitch
Autocaution
10
10
10
OFF
ON
Dipswitch
Immunity
11
11
11
N.O.
N.C.
Activation output
12
12
Dipswitch
12
N.O.
N.C.
Activation / Testoutput
(to the door controller)
12
12
Safety +
Safety
Dipswitch
Activation
AIR output
13
13
13
Enable
Disable
Dipswitch
Self monitoring
14
14
14
OFF
ON
Dipswitch
Lookback
15
15
15
OFF
ON
Dipswitch
Installation mode
16
16
16
All manuals and user guides at all-guides.com
Area adjustment tool
A
B
1-2 Microwave adjustment
Shallow
Depth angle adjustment screw
for the microwave area
Blue
Use the area adjustment tool (B) as shown above
to change the area depth angle.
Deep
Shallow
0
2-2 Microwave adjustment
To adjust the microwave detection area width, use the
narrow lens as shown in the picture below.
Narrow lens
2.Open
1.Remove screw
2.Open
3
Microwave sensitivity
Adjust the microwave detection area with potentiometer.
Afterwards, make sure to push the function switch for
2 seconds.
Mounting height : 2.2m (7'2")
Top view
Vertical adjustment : +35
Wide area
Narrow area
L
H
[mm(feet,inch)]
0
L
1000
(3'3")
L
2000
H
(6'6")
3000
H
(9'10")
3000
2000
1000
1000
2000
3000
0
(9'10")
(6'6")
(3'3")
(3'3")
(6'6")
(9'10")
push 2 seconds
Comment
Set the sensitivity according to the
High
S-High
mounting height. Values below dipswitch
are reference only. Adjust the sensitivity
1
2
1
2
according to your risk assessment.
To comply with EN16005, set the timer to
180sec
600sec
" 30sec." or more.To enable the presence
detection, do not enter the detection area
3
4
3
4
for 10 seconds after setting the timer.
When using more than two sensors close
Setting3
Setting4
to each other, set the frequency different
for each sensor.
5
6
5
6
The delay time between test input and
Safety / Test output is 10msec.
When dipswitch 9 is set to uni-directional,
this setting enables the door to close
earlier when a person walks away from
the door.
When dipswitch 10 is set to ON, a person
wavering in the motion detection area can
be detected. This is only effective when
dipswitch 9 is set to uni-directional.
Set dipswitch 9 to ON when the sensor
operates by itself (ghosting).
When dipswitch 11 is set to ON the actual
detection area may occur smaller.
Select N.O/N.C for the activation output
(OAM-DUAL T only)
Select N.O/N.C for the activation /
Testoutput.
(OAM-DUAL TT only)
When dipswitch 13 is ON, the sensor
outputs safety and activation simultane-
ously.
When the door remains open and the
operation indicator shows fast / slow green
blinking, refer to TROUBLESHOOTING.
If the door still remains open, set dipswitch
14 to "Disable".To comply with EN16005,
set the self monitoring to "Enable".
When dipswitch 15 is set to ON, the
lookback (1st row) is active and looks
through the threshold.
Set dipswitch 16 to ON to adjust the 2nd
row. After setting the row switch dipswitch
16 OFF. During the installation mode only
the 2nd row remains active and the
operation indicator shows yellow.
CHECKING
Check the operation in the operation mode according to the chart below.
Entry
Status
Operation indicator
12
N.O.
13
Safety
12
N.C.
OAM-
DUAL T/TT
Deep
Safety
12
N.O.
13
Activation
12
N.C.
Activation
output
13
Safety
OAM-
DUAL TV
13
Safety + Activation
13
Safety
OAM-
DUAL TF
13
Safety + Activation
Safety
7
High
/ Test
output
7
Low
*3.2V@10mA Min.4.5V(no load)
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
WARNING
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth. Do not use any cleaner / solvent.
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise an electric shock may occur.
4. When the operation indicator blinks green, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
1. When turning the power ON, always walk-test the detection area to ensure the proper operation.
NOTE
2. Do not place any objects that move or emit light in the detection area. (e.g. plant, illumination, etc.)
TO COMPLY WITH EN16005
Make sure to confirm the following content to comply with EN16005.
1. Detection area settings (See DETECTION AREA )
2. Presence timer (See ADJUSTMENTS 4. Dipswitch settings )
3. Self monitoring (See ADJUSTMENTS 4. Dipswitch settings )
°
TROUBLESHOOTING
Door operation Operation
indicator
None
Wrong power supply voltage.
Door does not
Wrong wiring or connection failure.
open when a
person enters
Unstable
Wrong detection area positioning.
the detection
Sensitivity is too low.
area.
Short presence timer.
Dirty detection window.
Proper
Wrong wiring or connection failure.
Objects that move or
Door opens
Unstable
emit light in the detection area.
when no one
is in the
The detection area overlaps with
detection area.
another sensor.
(ghosting)
Waterdrops on the detection window.
Detection area overlaps with door /
header.
Sensitivity is too high.
Raining or snowing
Others
Door remains
Proper
Sudden change in the detection area
open
Wrong wiring or connection failure.
Setting error of dipswitches
Installation mode is set to ON.
Yellow
Sensitivity is too low.
Fast
green
Dirty detection window
blinking
Sensor failure
Slow
Signal saturation (2nd or 3rd row)
green
blinking
The detection area overlaps with
the door / header.
Red &
Setting error of dipswitch and/or
green
potentiometer
blinking
Slow
Signal saturation (Lookback)
Proper
green
operation
blinking
*After changing the dipswitches and/or potentiometer settings, make sure to push the function switch for
2 seconds.
REFERENCE
Area depth adjustment with INFRARED FINDER (separately available)
1. Turn the depth angle adjustment screw to the right (deep) to place the detection area most away from the door.
2. Set INFRARED FINDER sensitivity to "H" (high) and place it on the floor as shown below.
3. Turn the depth angle adjustment screw to the left (shallow) until the emitting area is placed at the position where
INFRARED FINDER is in the low detection status (slow red blinking).
Manufacturer
OPTEX Co.,LTD.
5-8-12 Ogoto Otsu 520-0101, Japan
TEL.: +81(0)77 579 8700
FAX.: +81(0)77 579 7030
WEBSITE: www.optex.co.jp/as/eng/index.html
Outside of
Entry into
Entry into
Power OFF
detection
microwave area
3rd row
area
Motion
-
Stand-by
detection active
None
Orange
Green
Red
+
*
<=0.5V
0V
0V
*
<=0.5V
0Hz
0Hz
100Hz
100Hz
0Hz
0Hz
OFF
ON
OFF
OFF
Possible countermeasures
Possible cause
Set to the stated voltage.
Check the wires and connector.
Check ADJUSTMENTS 1, 2 ,3 & 4.*
Set the sensitivity higher.*
Set the presence timer longer.*
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Check the wires and connector.
Remove the objects.
Check Table 2 dipswitch 5, 6.*
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Adjust the detection area to "deep" (outside).
Or set dipswitch 11 to ON. *
Set the sensitivity lower.*
Set dipswitch 9 and / or dipswitch 11 to ON.*
Set dipswitch 11 to ON.*
Check Table 2 dipswitch 1 to 4*
If the problem still persists, hard-reset the
sensor.(Turn the power OFF and ON again)
Check the wires and connector.
Check Table 2 dipswitch 7, 8, 12, 14.*
Set dipswitch 16 to OFF.*
Set the sensitivity higher.*
Set AIR area width to "wide".
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Contact your installer or service engineer.
Remove highly reflecting objects from the
detection area. Lower the sensitivity.*
Change the area depth angle for AIR area.
Adjust the detection area to "deep". (outside)
After changing the dipswitches and/or
potentiometer settings, make sure to push the
function switch for 2 seconds.
Remove highly reflecting objects from the
detection area. Lower the sensitivity.*
Change the area depth angle for AIR area.
Detection area
INFRARED FINDER
Detection area
European Subsidiary
OPTEX Technologies B.V.
Tiber 2, 2491 DH The Hague, The Netherlands
TEL.: +31(0)70 419 41 00
FAX.: +31(0)70 317 73 21
E-MAIL: info@optex.eu
WEBSITE: www.optex.eu
Entry into
Entry into
Lookback
2nd row
(1st row)
Motion / Presence
detection active
Red blinking
Blue
*
<=0.5V
100Hz
0Hz
OFF
ON

Advertisement

loading

This manual is also suitable for:

Oam-dual tvOam-dual tfOam-dual tt