Treatment Table
SPL med 4
Fig. similar: colour and equipment may vary depending on model.
➢ Phone:
➢ Fax:
➢ Customer service hotline:
➢ E-mail:
➢ Web:
Empty field for entering the
The serial number of the SPL med 4 / 5 is on the
rating plate (s. chapter 7. R
Instruction Manual
SPL med 4 / SPL med 5
Gharieni Group GmbH
Am Schürmannshütt 24
D - 47441 Moers
SERIAL NUMBER
).
ATING PLATE
SPL med 5
+49 (0)2841/88300-0
+49 (0)2841/88300-999
+49 (0)2841/88300-40
service@gharieni.com
www.gharieni.com
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPL med 4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GHARiENi SPL med 4

  • Page 1 ➢ Customer service hotline: +49 (0)2841/88300-40 ➢ E-mail: service@gharieni.com ➢ Web: www.gharieni.com Empty field for entering the SERIAL NUMBER The serial number of the SPL med 4 / 5 is on the rating plate (s. chapter 7. R ATING PLATE...
  • Page 2: Table Of Contents

    SPL med 4 and SPL med 5: → in the instruction manual also referred to generally as BBREVIATIONS SPL med. REFACE Dear Customer, we would like to thank you for purchasing this quality-product as well as for your confidence. Read the complete IM before you use the SPL med for the first time.
  • Page 3 10.1.2 Manual control panel of the SPL med 5 ............24 10.1.3 Locking function: key lock button of the MCP of the SPL med 4 ..26 10.1.4 Locking function: key lock button of the MCP of the SPL med 5 ..26 10.1.5 Memory functions of the MCP of the SPL med 4 ........
  • Page 4 12. Initialisation of the software ..................32 13. Cleaning and maintenance .................... 34 13.1 Cleaning and care of the surface of the upholstery ........... 35 13.2 Cleaning of the housing and of the fittings ............35 14. Malfunctions (possible causes and troubleshooting) ..........35 14.1 Repair ..........................
  • Page 5: Safety Information

    Copies of this instruction manual are available upon request. ➢ The Gharieni Group GmbH shall not be held responsible for any damages, direct or indirect, caused to people, animals or objects resulting from negligence or non- compliance with the instructions contained herein.
  • Page 6: Signal Words

    1.2 Signal words indicates a hazardous WARNING! indicates a hazardous DANGER! situation which, if ignored, will result in situation which, if ignored, could result death or serious injury. in death or serious injury. NOTICE! indicates possible damage to CAUTION! indicates a hazardous the treatment table / appliance.
  • Page 7 purchased the treatment table at. Original spare parts should be used only. 10. When the power cable and / or the plug are damaged, it must be replaced by the manufacturer or an authorized aftersales service or a qualified professional only. Never try to repair or replace the power cable and / or the plug yourself.
  • Page 8 ELECTRIC SHOCK! RISK OF DAMAGE! 24. Any repairs and maintenance work must be carried out by qualified professionals authorized by the Gharieni Group GmbH only! RISK OF ELECTRIC SHOCK! RISK OF FIRE! 25. Do not use a steam cleaner for cleaning. RISK OF ELECTRIC SHOCK! 26.
  • Page 9 28. Persons, animals, objects or body parts of persons and animals must not be positioned between the base and the upper structure. RISK OF CRUSHING! 29. Persons, animals, objects or body parts of persons and animals must not be positioned under the parallelogram (s. fig. below). RISK OF CRUSHING! 30.
  • Page 10: Intended Use

    ❖ The Gharieni SPL med is a medical device relevant to the medical products law (German: MPG). It is suitable for medical use and thus complies with the requirements of EN 60601-1.
  • Page 11: Scope Of Delivery

    If you have purchased optional accessories for your treatment table, these are also included in the scope of delivery. 4. Preliminary remarks ❖ The Gharieni treatment table SPL med is subject to the highest safety and quality standards. ❖ Before initial operation, please check that all components are present and that they are not visible damaged.
  • Page 12: Unpacking

    5.2 Unpacking WARNING! While unpacking, the packaging materials (polythene bags, polystyrene pieces, etc.) should be kept away from children and pets. CHOKING HAZARD! RISK OF INJURY! LEASE OBSERVE THE FOLLOWING INSTRUCTIONS WHEN THE MED IS DELIVERED IN A CARDBOARD ➢ Open the top of the packaging carefully. Do not use any sharp-edged items which can damage the upholstery.
  • Page 13: Assembly

    NOTICE! When you have placed the SPL med in a suitable position providing sufficient free space, remove the carrying supports if necessary and store them at a safe place for future use. 6.3 Assembly ❖ The SPL med is easy to install and can be adapted to all human body measurements.
  • Page 14: Upholstery

    (mechanism for the height ASING OF THE PARALLELOGRAM adjustment) If you wish to contact the Gharieni customer service regarding your treatment table, we recommend taking a photo of the rating plate previously (e.g. using a mobile phone or a digital camera). This makes it easier for you to identify the information of the rating plate (e.g.
  • Page 15: Operation

    SPL med. RISK OF TIPPING! RISK OF DISINTEGRATION! RISK OF INJURY! 9.1 Characteristics ❖ The Gharieni SPL med is a treatment table which is either equipped with four or five actuators, according to the desired model version; s. chapter 9.2 M ODEL .
  • Page 16: Spl Med 4

    LEG SECTION ➢ All sections of the SPL med 4 can be adjusted electrically. ➢ The manual control panel of the SPL med 4 is equipped with eight memory positions as well as a locking function; see also chapter 10.1 M ANUAL CONTROL (MCP) et seq.
  • Page 17: View (Example: Spl Med 4)

    9.4 View (example: SPL med 4) Fig. similar / fig. shows the SPL med 4: colour, upholstery and design may vary depending on model. (supporting structure) Mechanism for the electrical HEIGHT ADJUSTMENT ➢ see also chapter 10.2 A DJUSTMENT OF THE WORK HEIGHT...
  • Page 18: Headrest

    Electrically-adjustable (SPL med 4): LEG SECTION ➢ see also chapter 9.4.3 L EG SECTIONS ➢ see also chapter 10.5.1 LEG SECTION OF THE The SPL med 5 is equipped with two separate electrically- adjustable leg sections: ➢ see also chapter 10.5.2 L...
  • Page 19: Armrests

    DJUSTMENT OF THE LEG SECTION LEG SECTIONS ❖ The two-part leg section of the SPL med 4 consists of an electrically-adjustable leg section and a manually-extendable footrest; s. fig in chapter 9.4 V ❖ The four-part leg section of the SPL med 5 consists of two separate and electrically-adjustable leg sections and two separate and manually-extendable footrests.
  • Page 20: Adjustments Of The Spl Med

    (lowered foot position). 10. Adjustments of the SPL med ❖ The electrical adjustments of the SPL med 4 and SPL med 5 are carried out using the relevant manual control panel (MCP). The actuators of the SPL med are equipped with the SPLINE - .
  • Page 21 EVEL STANDARD MODE BLACK LETTERING ➢ A : work height / backrest / seat inclination / leg section(s). CTUATOR CONTROL ➢ K : locking and unlocking of the manual control panel. EY LOCK BUTTON EVEL SHIFT MODE GREY LETTERING ➢ Saving and setting of the : M 1 - M 8.
  • Page 22: Manual Control Panel Of The Spl Med 4

    10.1.1 Manual control panel of the SPL med 4 ➢ Electrical adjustment of the WORK HEIGHT ➢ Electrical adjustment of the BACKREST ➢ Electrical adjustment of the SEAT INCLINATION ➢ Electrical adjustment of the LEG SECTION Fig. similar: modifications are possible.
  • Page 23 ➢ Push buttons for the adjustment of the (black SEAT INCLINATION lettering / arrows). C / C1 ➢ Push buttons for the saving and setting of the MEMORY M 5 and M 6 (grey lettering). POSITIONS ➢ Push buttons for the adjustment of the (black LEG SECTION lettering / arrows).
  • Page 24: Manual Control Panel Of The Spl Med 5

    10.1.2 Manual control panel of the SPL med 5 ➢ Electrical adjustment of the WORK HEIGHT ➢ Electrical adjustment of the BACKREST ➢ Electrical adjustment of the SEAT INCLINATION ➢ Electrical adjustment of the two separate LEG SECTIONS Fig. similar: modifications are possible. ➢...
  • Page 25 ➢ Push buttons for the adjustment of the (black SEAT INCLINATION lettering / arrows). C / C1 ➢ Push buttons for the saving and setting of the MEMORY M 5 and M 6 (grey lettering). POSITIONS ➢ Push buttons for the adjustment of the RIGHT LEG SECTION (black lettering / arrows).
  • Page 26: Locking Function: Key Lock Button Of The Mcp Of The Spl Med 4

    10.1.3 Locking function: key lock button of the MCP of the SPL med 4 ❖ The SPL med 4 is equipped with a of the manual control LOCKING FUNCTION panel to protect the treatment table from unauthorized access. OW TO ACTIVATE THE LOCKING FUNCTION 1.
  • Page 27: Memory Functions Of The Mcp Of The Spl Med 4

    10.1.5 Memory functions of the MCP of the SPL med 4 ❖ The manual control panel of the SPL med 4 is equipped with eight memory positions (memory functions on level 2: M 1 / M 2 / M 3 / M 4 / M 5 / M 6 / M 7 / M 8).
  • Page 28: Memory Functions Of The Mcp Of The Spl Med 5

    OW TO SELECT A PREVIOUS SAVED MEMORY POSITION 1. Press the (4). The diode goes on ( SHIFT BUTTON LEVEL 2. Press and hold the desired (hotkey M 1 - M 8) MEMORY BUTTON M 1 - M 8 until the position has been reached. 10.1.6 Memory functions of the MCP of the SPL med 5 ❖...
  • Page 29: Adjustment Of The Work Height

    10.2 Adjustment of the work height ❖ For the adjustment of the press the corresponding pair of push WORK HEIGHT buttons (A / A1) of the relevant MCP; s. fig. in chapter 10.1 M ANUAL CONTROL (MCP) et seq. PANEL ❖...
  • Page 30: Adjustment Of The Seat Inclination

    ❖ For the adjustment of the press the corresponding pair of push LEG SECTION buttons (D / D1) of the MCP of the SPL med 4; see also chapter 10.1.1 M ANUAL CONTROL PANEL OF THE ❖ The direction of movement (up or down) is indicated by the arrow-symbols.
  • Page 31: Leg Sections Of The Spl Med 5

    (s) / 9, so you can work on the heel FOOTREST area (pedicure). This setting is also suitable when you want to carry out massages without using additional tools (lowered foot position). SPL med 4 SPL med 5 Fig. similar: colour may vary depending on model. Electrically-adjustable...
  • Page 32: Rotunda (Optional Equipment)

    11. Rotunda (optional equipment) ❖ This option enables the seat of the treatment table to be rotated up to 330 . You can freeze the set position for treatment using the hand lever which is located below the seat (s. fig. below). Loosen the hand lever by one rotation of the hand in clockwise direction, rotate the seat to the desired position and tighten the lever by turning it in anti-clockwise direction.
  • Page 33 SPL med 4: the actuator of the leg section of the SPL med 4 has also to be set to min., i.e. keep pressing button D1 of the relevant manual control panel until this actuator is also switched off;...
  • Page 34: Cleaning And Maintenance

    13. Cleaning and maintenance WARNING Disconnect the SPL med from the mains (unplug) before cleaning and maintenance. RISK OF ELECTRIC SHOCK! RISK OF FIRE! WARNING! Remove possible dust accumulation at the power plug, at the safety power socket and at all plug connectors regularly. RISK OF FIRE! WARNING! Ensure that water or other liquids cannot get into the housing and the fittings of the SPL med or into the MCPs.
  • Page 35: Cleaning And Care Of The Surface Of The Upholstery

    Clean and care the using a special detergent for artificial ARTIFICIAL LEATHER leather only optional available at Gharieni; s. chapter 15. O PTIONALLY AVAILABLE ACCESSORIES 13.2 Cleaning of the housing and fittings Clean the housing and the fittings using a soft damp cloth and a small amount of soap.
  • Page 36: Repair

    1. When contacting the customer service, the information about the serial number is absolutely necessary. 2. Repairs and modifications must be carried out by Gharieni Group GmbH or a person authorized by Gharieni Group GmbH. 3. The electrical installation of the room the SPL med is installed in must meet the current legal regulations at the site where the SPL med is operated.
  • Page 37: Optionally Available Accessories

    15. Optionally available accessories  For detailed information regarding the optionally available accessories (s. below) please contact the Gharieni customer service. We will be glad to advise you! 15.1 Castor set ❖ A...
  • Page 38: Xl Widening

    ❖ This allows, in conjunction with the optional head parts, nearly every conceivable treatment at the head.  For detailed information regarding the please MULTIFUNCTIONAL MOUNTING contact the Gharieni customer service. 15.4.1 Crescent headrest ❖ A (s. fig below) for the CRESCENT HEADREST MULTIFUNCTIONAL MOUNTING optional available for an additional charge.
  • Page 39: U-Shaped Headrest

    ❖ Therefore, there is better access to the neck and shoulder area. ❖ During treatment, the head of the customer is firmly fixed in stable position. Can be used in connection with the only. MULTIFUNCTIONAL MOUNTING Article number: 48002 RESCENT HEADREST Article number: 48005 RTIFICIAL LEATHER COVER / 10...
  • Page 40: Protective Covers For Treatment Tables

    Fig. Similar: fig serves as an example only!  For detailed information regarding the right size and suitable version of the covers as well as the compatibility with your treatment table please contact the Gharieni customer service. We will be glad to advise you!
  • Page 41: Conditions Of Transport, Storage And Operation

    16. Conditions of transport, storage and operation 16.1 Transport ❖ Carry the SPL med by its base / supporting structure during transport only. ❖ Never carry the SPL med by its lying / sitting surface or its armrests during transport; otherwise you can damage the SPL med seriously. ❖...
  • Page 42: Technical Data

    17. Technical data 5/ G ENERAL TECHNICAL DATA Total length approx. 203.00 cm Width (max.) approx. 80.00 cm Range of height adjustments incl. adjustable feet approx. 55.00 cm - 96.00 cm Range of height adjustments incl. castors approx. 63.00 cm - 104.00 cm (approx.
  • Page 43: Waste Management

    9. If suitable containers are not available at your residential area, dispose of these materials at a suitable municipal collection point for waste-recycling. 10. Receive more detailed information from your retailer, municipal facilities or: Gharieni Group GmbH ➢ Phone: +49 (0)2841/88300-0 ➢...
  • Page 44: Guarantee Provisions

    19.1 Guarantee period The following guarantee provisions apply to new goods worldwide: The Gharieni Group GmbH offers for all treatment tables of the SPL med series. → a 10-year guarantee for their metal frames, → a 5-year guarantee for their actuators and →...
  • Page 45: Ec-Declaration Of Conformity

    EU, (Type or model, name) SPL med 4 / SPL med 5 2019 Relevant EU directives and harmonized standards used:...
  • Page 46: Status Of Edition

    RESERVED. ITS REPRODUCTION OR TRANSMISSION TO THIRD PARTIES IS FORBIDDEN WITHOUT THE AUTHORISATION OF THE OWNING COMPANY. THE POWER TO PROTECT ITS RIGHTS IS RESERVED AND OFFENDERS SHALL BE PROSECUTED. Gharieni Group GmbH Am Schürmannshütt 24 D - 47441 Moers...

This manual is also suitable for:

Spl med 5