Page 1
Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear systems.
1. WARNING: ......................4 2. INSPECTION OF THE MATERIAL UPON RECEIPT OF THE EQUIPMENT: ....1 LIST OF COMPONENTS ....................1 3. EDT-150-5191 SYSTEM DESCRIPTION ..............2 4. CHARGER FUNCTION ..................4 5. FEATURES: ......................6 ELECTRICAL, ENVIRONMENTAL AND MECHANICAL CHARACTERISTICS: ........6 ELECTRICAL BEHAVIOUR: ....................
Use in accordance with the intended purpose. The device must only be used for its intended purpose. Any use not in accordance with the purpose is prohibited. PREMIUM S.A. cannot be held liable for damages resulting from improper use. In such a case, the user must assume sole responsibility for the risk.
Then check that all the items listed in 1.1 have been correctly supplied. 2.1.1.1 LIST OF COMPONENTS The product consists of the following parts: • Charger EDT-150-5191 • 4-pole female connector for mains input • 8-pole female connector for output and battery •...
EDT-150-5191 SYSTEM DESCRIPTION The EDT-150-5191 is a 12V battery rectifier-charger capable of managing the charging of lead batteries up to 40Ah capacity. The total power it can deliver without the aid of the battery is 150W permanently, 275W for 25 seconds and 300W for 10 seconds every minute. If the battery is connected and in good condition, the output can provide a total power of 300W for 60 seconds.
Page 7
The function of this equipment is that of an uninterrupted power supply system, the mission of which is to keep the charges powered at all times. For this, you must: -Provide an uninterrupted power supply at its outputs and within the specified range. -Protect against normal operating situations (power-up, punctual overloads, etc.) as well as abnormal situations (short-circuits and permanent overloads at its output, etc.).
Control Signalling Local Ethernet Figure 3. Block diagram EDT-150-5191 4. CHARGER FUNCTION This equipment is powered at an input voltage of 230VAC (range 184-265Vac), acting as switched AC/DC converters, with galvanic isolation between input and output (up to 2kV at industrial frequency and 5kV lightning impulse).
Page 9
AC mains voltage returns or a reconnection from the battery is forced by means of the button enabled for this purpose. Figure 4. Charger EDT-150-5191 This equipment has a battery status control system (battery test). The condition of the batteries is monitored periodically.
5. FEATURES: 5.1.1.1 ELECTRICAL, ENVIRONMENTAL AND MECHANICAL CHARACTERISTICS: AC INPUT FEATURES Mains input voltage 230Vac Mains voltage range -20%...+15% Mains frequency range 47...63Hz Starting current < 12A DC OUTPUT FEATURES OUTPUT 1 OUTPUT 2 OUTPUT 3 (communications) (native) (motors) Battery voltage 12 V Nominal output voltage 13.62 V...
Page 11
300 W 40 W 200 W Delivering 150W across the charger and the rest the battery. Curly 50mVpp 100mVpp 100mVpp Noise (BW 20MHz) 100mVpp 200mVpp 200mVpp Performance: >84% At nominal input voltage and (See annex with efficiency curve) nominal power CHARGER FEATURES Battery type Watertight lead...
Figure 5. Dimensions and wiring EDT-150-5191 5.1.1.2 ELECTRICAL BEHAVIOUR: The following groups have been defined to specify the dielectric strength: GROUP SIGNAL AC input Alarms Temperature sensor + 48V Output + Battery + NC Ethernet Port Earth The dielectric strength between groups is as follows:...
Page 13
• Protection against mains overvoltage via varistors. • Protection against secondary overvoltage. • Protection against overload and short-circuit of outputs via current limitation. The battery has various degrees of protection: • Electronic limitation of the charging current. • Short-circuit protection via a self-rearming fuse. •...
5.1.1.4 SIGNALLING The module has eight LEDs on the front for local signalling: LED name Colour Mode Signal Equipment running Green Fixed light Charger running Fixed light Battery charging float mode Charging status Green Flashing Battery charging constant voltage mode Battery test running Green Fixed light...
Closes when the output voltage is out of range, the battery temperature is out Non-urgent failure of range or there is a temperature sensor error. Figure 6. Detail of alarms EDT-150-5191. A more detailed description of the operation of the equipment can be found in section 3.2 of this operation manual.
5.1.1.6 WIRING AND SIGNALS: 5.1.1.7 TERMINAL BLOCKS AND SIGNALS: The connection of the EDT-150-5191 charger is as follows: Connector Pins Signal Features Minimum Maximum cross- cross- section section Earth Safety earth Functional Earth (for EMC) Entrance No connection 0.75 mm 2.5 mm...
Page 17
Mains Failure NA Contact Alarm (FAC) End of Autonomy NA Contact Alarm (FAU) Urgent Failure NC Contact Alarm (URG) Ethernet Port Figure 7. Detail of J1 and earth terminal Figure 8. Detail of J2 Figure 9. Detail of J3 MA-5191A 21-10-2021 13 / 110...
Page 18
Figure 10. Detail of J4 and ETH MA-5191A 21-10-2021 14 / 110...
5.1.1.8 BUTTON: The EDT-150-5191 charger has a button (BT1) indicated on the front panel as "Battery Reconnection". Figure 11. Position of the BT1 button on the EDT-150-5191 chargers. The button allows the following functions: Starting the charger without AC power: When the charger is completely stopped...
Therefore, it is always possible to access the equipment for configuration by connecting to it through the LOCAL IP even if the REMOTE IP configured is unknown. Ways to change the active IP: Switch to LOCAL IP: the equipment must be switched on and running. In addition, the button must be kept pressed for 10s.
5.1.1.11 COMMUNICATIONS: The EDT-150-5191charger has an Ethernet port for communications. The charger has a Web interface that allows consulting the output voltage, power consumed at the output, detailed alarms, equipment configuration, loaded firmware, battery status, etc. The equipment allows loading of configurations via an XML configuration file and/or by changing parameters with a generic web browser (for more details, see the equipment’s communications operations manual).
It is important not to cover the ventilation slots so that air can circulate freely. Figure 13. Typical mounting position view EDT-150-5191 and EARTH PROTECTION connection The weight of the charger, including connectors, is less than 1.7kg.
6.1.1.1 INSTALLATION REQUIREMENTS The installation of the equipment should be carried out in a location combining the following characteristics: • The penetration of liquids, dust and/or objects into the equipment through the ventilation grilles must be prevented; otherwise, its integrity would be put at risk. •...
13.6V- Battery+ Neutral Battery- Entrance 48V (40W)- 48V (40W)+ +48Vd Phase 48V- 48V+ +48Vd EDT-150-5191 Sensor Temp. Earth Management unit Potential-free alarms Alarm relays Ethernet local area Ethernet network Figure 15. General wiring diagram. The following figure shows the layout of the connectors: Figure 16a.
Figure 17. AC and earth connection. It must be ensured that the earth connection by means of the bolt is made to a safety earth. The earth must be connected both to the BLZP 5.08HC/04/180F connector and to the bolt shown in the figure below.
(hundreds of amperes) can cause the battery to explode and melt cables, tools and other metal objects. 7.1.1.3 BATTERY TEMPERATURE PROBE CONNECTION: The EDT-150-5191 charger incorporates a pre-wired temperature sensor to measure the ambient temperature near the batteries. Only the temperature probe supplied with the charger should be used.
The probe must be connected to the connector established for this purpose, as shown in the following figure: Figure 19. Temperature sensor connection If the temperature probe is not connected correctly, the charger generates an equipment anomaly alarm (signalled by LED). If this error is not resolved, the charger will stop compensating the battery voltage and it will become fixed (corresponding to the reference temperature of 25ºC) The temperature probe supplied incorporates the plug-in connector at one end and an EPOXY-...
Page 30
The use of CAT5E or higher category commercial cables is recommended to ensure optimum data transfer rate. This is because the use of manually crimped connectors can degrade signal quality and negatively affect communications performance. Figure 21. Ethernet connection MA-5191A 21-10-2021 26 / 110...
8. COMMISSIONING Before starting up the equipment, make sure that all connections are correct, respecting the polarities indicated on the front of the unit. The temperature sensor has the function of informing the charger of the ambient temperature of the battery, in order to adjust the charging parameters accordingly. It should be installed in the same room or cabinet as the battery, as close as possible to the battery.
9. OPERATION The EDT-150-5191 charger has automatic operation and does not require any user intervention to perform usual tasks. The operation commands (such as force battery test, force fast charge, etc.) are carried out through the web interface (as specified in the communications manual).
LOCAL IP: 100.0.0.1 The REMOTE IP will be modified according to the installation site. The LOCAL IP mode is accessed by pressing and holding BT1 for 10s (with the charger running); the unit will indicate that it has entered LOCAL IP by flashing all LEDs.
10.1.1.2 BATTERY CONSUMPTION: In these systems, batteries are used as elements in which energy is stored during the periods in which power is available from the electrical grid. When there is a failure in this supply, the batteries are responsible for providing energy to the connected elements, providing autonomy to the system until they are exhausted.
Page 36
BATTERY CURRENT I max. charge I step to float Maximum time at constant V I discharge AC INPUT BATTERY STATUS AC FAILURE FLOTATION CONSTANT VOLTAGE (FAST FLOTATION BAT. DISCHARGE CHARGING) Figure 23. EDT-150-5191 charge modes chart MA-5191A 21-10-2021 32 / 110...
This energy will be used to power the charger control and the charges connected to its outputs. The power consumption of the control in this situation is less than 4% of the nominal power for the EDT-150-5191 (intended to maintain the functionality of the charger status machine, digital outputs, light indications and communications via Ethernet).
Then reapply the input voltage. Reset it from the web page. 13.1.1.3 VARIATION OF FLOAT VOLTAGE WITH TEMPERATURE: The EDT-150-5191 charger varies the output voltage according to battery temperature to maximise battery life. This procedure ensures that: The battery float voltage varies according to the temperature measured by the battery temperature sensor.
Page 39
The correct operation of the parameters in their full range (as long as they do not jeopardise the integrity of the battery). MA-5191A 21-10-2021 35 / 110...
13.1.1.4 CONNECTION AND BATTERY CHARGING: The EDT-150-5191 charger has defined charging modes: -Constant voltage charging (or fast charging). -Flotation. During constant voltage (or fast charge) charging mode, the charger sets a charge voltage higher than the float voltage (output 1 of the charger). The main features of this mode are: The charge current is limited to a maximum (unlimited) value.
13.1.1.6 RECOVERING BATTERY: The EDT-150-5191 charger incorporates a battery recovery process. Its function is to try to recover a battery with voltage values outside the established limits. Field experience has shown that some batteries can partially recover after deep discharge. This allows for a certain degree of autonomy in the event of network failures that would otherwise not be feasible.
Page 42
I max. charge I step to float I discharge. AC INPUT FAILURE AC Y AC FAILURE CONSTANT VOLTAGE RECOVERY DEEP BATTERY STATUS BAT. DISCHARGE (FAST CHARGING) FLOTATION BATTERY DISCHARGE BAT. Figure 24. EDT-150-5191 Battery recovery status graph MA-5191A 21-10-2021 38 / 110...
13.1.1.7 BATTERY TEST: The EDT-150-5191 charger has a battery test (parameterisable) in which the available battery capacity is measured. This test is performed periodically (also configurable by default every 16 weeks). During this test, the battery is discharged by its own charge connected to the outputs of the equipment.
Pushing the button on the equipment. This method does not interrupt the power supply to the charge. 13.1.1.9 POWER DISTRIBUTION: The EDT-150-5191 charger has 3 outputs that have been designed to supply different types of charges: Output 1: Considered the native output and is the one directly connected to the battery.
AC fuse: 5x20 slow crystal 5A BATTERY fuse: Automotive Fast Acting Fuse 30ª 14.1.1.2 BATTERIES The EDT-150-5191 charger allows hot-swapping your batteries without disconnecting the equipment. • Battery replacement may be due to: Battery test failure. Preventative maintenance or replacement campaigns Other reasons (damage, breakage, etc.).
Page 46
b. Access the website and click on the battery reconnection force. 7. The charger detects the presence of the battery: a. With the battery correctly connected, the charger should switch to fast charge mode. If, prior to changing the battery, the charger has had a battery test failure, it will reset, causing the Battery error LED to turn off and the “Urgent alarm"...
In this case, the equipment will recover. If this is not the problem, the error will persist and the system will require human action to be replaced. NOTE 4: Check that the battery sensor is connected. If it is connected, replace it with a new one, otherwise connect a sensor supplied by PREMIUM. MA-5191A 21-10-2021...
Page 48
NOTE 5: This may be caused by an overload on the output; if so, the equipment will periodically check if the overload persists. If the overload disappears, the equipment will recover. This can also be caused by a failure in the regulation of the equipment. If this problem persists, replace with new equipment to check whether it is an overload on the output or a fault in the equipment.
16. STANDARD The EDT-150-5191 is a CE-marked product, which complies with the directives listed below: Low voltage Level Standard Low voltage directive 73/23/EEC-93/68/EEC une-en 50178 (98) Radioelectric Disturbances Level Standard Conducted emissions at power terminals Class A, Class B UNE EN 55022...
Page 50
Mechanical Level Standard IP protection level IP20 UNE EN 20324 IK protection level IK05 UNE EN 50102 Vibration Class 2.3 ETSI EN 300 019-2-2 Fall Class 2.3 ETSI EN 300 019-2-2 Climatic Level Standard Moist heat 40ºC/93%/4 days UNE EN 60068-2-78 Dry heat 70ºC/16h UNE EN 60068-2-2...
17. LABELLING: The EDT-150-5191 charger is identified by a model label located on the front of the equipment. This label withstands a marking test and makes it highly resistant to erasure (it withstands being rubbed with hexane solvent for at least 15 seconds).
Individual packaging is in a cardboard box with bubble wrap and retention via 2 Insta pack foam bags. The product consists of the following parts: • Charger EDT-150-5191 • 4-pole female connector for mains input • 8-pole female connector for output and battery •...
Out of its packaging, it is a fairly robust product overall, although it can be damaged by bumps or drops. 21. TRANSPORT: The EDT-150-5191 does not require a specific transport process. Shipment is in individual boxes. • All equipment has been functionally tested prior to shipment •...
That the product reference matches the order reference • That the amount is as requested If any incorrect information is found, please notify PREMIUM S.A. as soon as possible. A visual inspection should then be carried out by checking the following: •...
Page 55
In case of damage, please notify PREMIUM S.A. promptly, preferably attaching detailed photographs. MA-5191A 21-10-2021 51 / 110...
21.1.1.2 STORAGE: The EDT-150-5191 charger can be stacked in up to 8 boxes under the conditions indicated below, although the severity reduces the maximum storage time. For prolonged storage, due to the degradation of some components due to lack of use, the equipment should be planned to be started up for at least 8 hours every two years.
22. ENVIRONMENTAL INFORMATION: Premium S.A., in order to provide an acceptable level of protection for people and property, and taking into consideration the recommendations applicable to the respect of the environment, designs and manufactures its products according to the principle of integrated safety, based on the following criteria: •...
23. GUARANTEE PREMIUM S.A., unless otherwise agreed, guarantees to the Customer that the manufacture of the Equipment shall be free from defects for a period of 2.5 years from the date of delivery to the Customer. If any defect is detected, the manufacturer may choose to repair or replace the equipment.
24. ANNEXES: 24.1.1.1 Annex A: Performance curves for EDT-150-5191: The following figure shows the performance curve of the EDT-150-5191 charger applying charge only on output 1. Output Power [W] Figure 28. Performance graph EDT-150-5191 The following figure shows in more detail the performance of the charger for powers higher than 20W.
Page 60
1. PRECAUCIONES: ....................58 2. INSPECCIÓN DEL MATERIAL ANTE LA RECEPCIÓN DEL EQUIPO: ...... 59 2.1 LISTADO DE COMPONENTES ......¡ERROR! MARCADOR NO DEFINIDO. 3. DESCRIPCIÓN DEL SISTEMA EDT-150-5191 ............. 60 4. FUNCIONAMIENTO DEL CARGADOR ..............62 5. CARACTERÍSTICAS: ..................64 CARACTERISTICAS ELÉCTRICAS, AMBIENTALES Y MECÁNICAS: ...........
Page 61
: ......................101 RANSPORTE 15.2 RECEPCIÓN: ......................102 15.3 ALMACENAMIENTO: ....................103 16. INFORMACIÓN MEDIOAMBIENTAL: ..............104 17. GARANTIA ...................... 105 18. ANEXOS: ......................106 18.1 A A: C EDT-150-5191: ............106 NEXO URVAS DE RENDIMIENTO PARA MA-5191A 21-10-2021 57 / 110...
PREMIUM S.A. Si se usan piezas de repuesto, solamente se deben emplear las piezas originales de PREMIUM S.A. PREMIUM S.A. declina cualquier responsabilidad resultante de una inadecuada, negligente o incorrecta instalación del equipo, o de una conexión incorrecta del mismo.
1.1 se han suministrado correctamente. 2.1.1.1 LISTADO DE COMPONENTES El producto se compone se las siguientes partes: • Cargador EDT-150-5191 • Conector hembra de 4 polos para la entrada de red • Conector hembra de 8 polos para la salida y batería •...
3. DESCRIPCIÓN DEL SISTEMA EDT-150-5191 El EDT-150-5191 es un rectificador-cargador de baterías de 12V capaz de gestionar la carga de baterías de plomo de hasta 40Ah de capacidad. La potencia total que puede suministrar sin la ayuda de la batería es de 150W de forma permanente, 275W durante 25 segundos y 300W durante 10 segundos cada minuto.
Page 65
-Suministrar en sus salidas una alimentación ininterrumpida y que se encuentre dentro de los márgenes especificados. -Protegerse frente a situaciones normales de funcionamiento (Power-up, sobrecargas puntuales, etc), así como anormales (cortocircuitos y sobrecargas permanentes en su salida, etc.). -Realizar un tratamiento adecuado de las baterías que son necesarias para su funcionamiento: -Procurando maximizar la vida y minimizar el tiempo de carga de éstas.
Chasisa Local Ethernet Figura 3. Diagrama de bloques EDT-150-5191 4. FUNCIONAMIENTO DEL CARGADOR Este equipo alimentado a una tensión de entrada de 230VAC (margen de 184-265Vac), actúan como convertidores AC/DC conmutados, con aislamiento galvánico entre la entrada y la salida (hasta 2kV a frecuencia industrial y 5kV de impulso tipo rayo).
Page 67
Figura 4. Cargador EDT-150-5191 Este equipo dispone de un sistema de control del estado de las baterías (Test de baterías). La supervisión del estado de las baterías se realiza de forma periódica. Además, esta medida se realiza siempre cuando las baterías se encuentran en flotación.
5. CARACTERÍSTICAS: CARACTERISTICAS ELÉCTRICAS, AMBIENTALES Y MECÁNICAS: CARACTERÍSTICAS DE LA ENTRADA CA Tensión de entrada de red 230Vac Margen de tensión de red -20%...+15% Margen de frecuencia de red 47...63Hz Corriente de arranque < 12A CARACTERÍSTICAS DE LA SALIDA DC SALIDA 1 SALIDA 2 SALIDA 3...
Page 69
Refrigeración Convección natural Altitud <1000m Requerimientos medioambientales RoHS según directiva 2002/95/CE CARACTERISTICAS MECÁNICAS Dimensiones: 265,5x115x90,2mm (Ancho x Alto x Fondo) Incluyendo los conectores. Peso: <1.7kg Grado de protección IP20 Figura 5. Dimensiones y conexionado EDT-150-5191 MA-5191A 21-10-2021 65 / 110...
COMPORTAMIENTO ELÉCTRICO: Para especificar la rigidez dieléctrica se han definido los siguientes grupos: GRUPO SEÑAL Entrada AC Alarmas Sensor de temperatura + Salida de 48V + Batería + NC Puerto Ethernet Tierra La rigidez dieléctrica entre grupos es como sigue: Polos de prueba Impulso tipo Rigidez...
SEÑALIZACIONES El módulo dispone de ocho diodos LED en el frontal para señalización local: Nombre LED Color Modo Indicación Equipo en marcha Verde Luz fija Cargador en marcha Luz fija Carga de baterías modo flotación Régimen de carga Verde Parpadeo Carga de baterías modo tensión constante Test de batería en marcha Verde...
Fallo no urgente baterías está fuera de rango o hay error del sensor de temperatura. Figura 6. Detalle alarmas EDT-150-5191. En el apartado 3.2 de este manual de operaciones puede hallarse una descripción más detallada del funcionamiento de los equipos.
CONEXIONADO Y SEÑALES: 5.6.1 BORNEROS Y SEÑALES: El conexionado del cargador EDT-150-5191 es el siguiente: Conector Pines Señal Características Sección Sección mínima máxima Tierra Tierra de seguridad Tierra Funcional (para EMC) Sin conexión 0,75 mm 2,5 mm Entrada Entrada AC, Neutro N...
Page 74
Figura 7. Detalle de J1 y terminal de tierra Figura 8. Detalle de J2 Figura 9. Detalle de J3 Figura 10. Detalle de J4 y ETH MA-5191A 21-10-2021 70 / 110...
5.6.2 PULSADOR: El cargador EDT-150-5191 dispone de un botón (BT1) indicado en el frontal como “Reconexión Batería”. Figura 11. Posición del pulsador BT1 en los cargadores EDT-150-5191. El pulsador permite las siguientes funciones: Arranque del cargador sin alimentación alterna: Cuando el cargador se encuentra completamente parado (sin entrada AC pero con las baterías conectadas), si se pulsa el botón durante 5 segundos,...
5.6.3 SENSOR DE TEMPERATURA El cargador EDT-150-5191 incorpora precableado un sensor de temperatura destinado a medir la temperatura ambiente próxima a las baterías con el fin de optimizar la vida de estas. Mediante la compensación de la tensión de salida con la temperatura, estos cargadores consiguen maximizar la vida útil de las baterías utilizadas.
Page 77
El equipo permite realizar la carga de configuraciones mediante un fichero de configuración XML y/o mediante cambio de parámetros con navegador web genérico (para más detalle véase el manual de operaciones comunicaciones del equipo). MA-5191A 21-10-2021 73 / 110...
Es importante no cubrir las ranuras de ventilación para que el aire pueda circular libremente. Figura 13. Vista posición de montaje típico EDT-150-5191 y conexión de TIERRA DE PROTECCIÓN Peso del cargador, incluidos los conectores, es menor de 1.7kg.
CONDICIONES DE INSTALACIÓN La instalación del equipo deberá realizarse en un lugar que reúna las siguientes características: • Se ha de evitar la penetración de líquidos, polvo y/u objetos al interior del equipo a través de las rejillas de ventilación; de lo contrario pondría en riesgo su integridad. •...
13,6V- Batería+ Neutro Batería- Entrada 48V (40W)- +48Vcc 48V (40W)+ Fase 48V- 48V+ +48Vcc EDT-150-5191 Sensor Temp. Tierra Unidad de gestión Relés de Alarmas libre de Alarma potencial Red de área local Ethernet Ethernet Figura 15. Esquema general de conexionado.
Sección de cobre Sección de cobre máxima Función Conexión mínima recomendada admisible Entrada de red Fase, Neutro, Tierra 1 mm 2.5 mm Batería Batería +, 4-Batería - 4 mm 4 mm Salida 12V Salida 1+,Salida 1- 4 mm 4 mm Salida 48V motor Salida 3+,Salida 3- 1 mm...
CONEXIÓN DE LA SONDA DE TEMPERATURA DE BATERÍA: El cargador EDT-150-5191 incorpora precableado un sensor de temperatura destinado a medir la temperatura ambiente próxima a las baterías. MA-5191A...
Deberá utilizarse únicamente la sonda de temperatura suministrada con el cargador. El cable de dicha sonda es de 2m de longitud. Será posible el suministro del sensor con otras longitudes bajo demanda (tamaños estándar de 5m y 10m disponibles). La conexión de la sonda deberá realizarse en el conector establecido a tal efecto, tal y como puede verse en la siguiente figura: Figura 19.
Page 84
Se recomienda el uso de cables comerciales de categoría CAT5E o superior para garantizar una tasa óptima de transferencia de datos. Esto es debido a que el uso de conectores crimpados manualmente puede degradar la calidad de la señal y afectar negativamente en el desarrollo de las comunicaciones. Figura 21.
8. PUESTA EN MARCHA Antes de poner en marcha el equipo asegurarse de que todas las conexiones son correctas, respetando las polaridades indicadas en la parte frontal. El sensor de temperatura tiene la función de informar al cargador de la temperatura ambiente de la batería, para así...
9. OPERACIÓN El cargador EDT-150-5191 dispone de un funcionamiento automático y no necesitan de la intervención de ningún usuario para realizar las tareas habituales. Las órdenes propias de funcionamiento (como forzar test de batería, forzar carga rápida,…) se realizan a través del interface web (tal y como se especifican en el manual de comunicaciones).
Pulsando nuevamente el pulsador durante 10s. Por tiempo. El cargador pasa automáticamente a IP REMOTA tras 20 minutos en modo IP LOCAL. 10. PROCESOS: 10.1 ALARMAS: En la siguiente tabla pueden observase las alarmas disponibles en estos equipos y la lógica asociada a cada una de ellas: Nombre Alarma Estado...
10.2 CONSUMO DE BATERÍA: En estos sistemas se utilizan baterías como elementos en los que se almacena energía durante los periodos en los que se dispone de suministro procedente de la red eléctrica. Cuando se produce un fallo en este suministro, las baterías son las encargadas de proporcionar la energía a los elementos conectados, dotando de autonomía al sistema hasta que las estas se agotan.
Page 89
I carga máx. I paso a flotación Tiempo máximo a V constante I descarga ENTRADA AC ESTADO BATERÍA FALLO AC FLOTACIÓN TENSIÓN CONSTANTE FLOTACIÓN DESCARGA BAT. (CARGA RÁPIDA) Figura 23. Gráfica modos de carga EDT-150-5191 MA-5191A 21-10-2021 85 / 110...
El consumo del control en esta situación es inferior al 4% de la potencia nominal para el EDT-150-5191 (destinados a mantener la funcionalidad de la máquina de estados del cargador, las salidas digitales, indicaciones luminosas y las comunicaciones vía Ethernet).
Reseteándolo desde la página web. 10.5 VARIACIÓN DE LA TENSIÓN DE FLOTACIÓN CON LA TEMPERATURA: El cargador EDT-150-5191 varía la tensión de salida en función de la temperatura de las baterías para maximizar la vida útil de éstas. Este procedimiento garantiza que: La tensión de flotación de la batería varía en función de la temperatura medida mediante el sensor...
10.6 CONEXIÓN Y CARGA DE BATERÍA: El cargador EDT-150-5191 tiene definidos modos de carga: - Carga a tensión constante (o carga rápida). - Flotación. Durante el modo de carga a tensión constante (o carga rápida), el cargador fija una tensión de carga superior al de flotación (salida 1 del cargador).
10.8 RECOVERING BATTERY: El cargador EDT-150-5191 incorpora un proceso de recuperación de baterías. Su función es la de tratar de recuperar una batería con valores de tensión fuera de los límites establecidos. La experiencia en campo ha demostrado que algunas baterías tras sufrir una descarga profunda pueden recuperarse parcialmente. Esto permite disponer de una cierta autonomía en caso de fallos de red que de otra manera no sería factible.
Page 94
I paso a flotación I descarga. ENTRADA AC FALLO AC Y FALLO AC TENSIÓN CONSTANTE RECUPERACIÓN DESCARGA ESTADO BATERÍA DESCARGA BAT. (CARGA RÁPIDA) FLOTACIÓN BATERÍA PROFUNDA BAT. Figura 24. Gráfica del estado de recuperación de batería EDT-150-5191 MA-5191A 21-10-2021 90 / 110...
10.9 TEST DE BATERÍA: El cargador EDT-150-5191 dispone de un test de batería (parametrizable) en el cual se mide la capacidad disponible de la batería. Este test se realiza periódicamente (también parametrizable por defecto cada 16 semanas). Durante este test la batería se descarga mediante la propia carga conectada a las salidas del equipo.
CAMBIO DE BATERÍA: Con el cargador EDT-150-5191, el cambio de batería puede estar motivado porque se ha generado una alarma de “Fallo urgente” motivada a su vez por la alarma de “Fallo de batería”. En esta situación se bloquea la ejecución periódica del test de batería.
Fusible BATERÍA: Fusible Automoción de Acción Rápida 30ª 11.2 BATERÍAS El cargador EDT-150-5191 permite la sustitución de sus baterías en caliente sin necesidad de desconectar el quipo. • La sustitución de las baterías puede ser debida a: Fallo del test de batería.
Page 98
• Conexionado: Deberá comprobarse el apriete de las tuercas sobre los polos de los elementos, así como el apriete del conexionado eléctrico a intervalos regulares (12 meses aproximadamente) • Verificación de las tensiones: Deberá comprobarse las tensiones de los elementos para detectar posibles anomalías en ellos. •...
NOTA 4: Comprobar que el sensor de batería está conectado. Si está conectado cambiar por otro nuevo, en caso contrario conectar un sensor suministrado por PREMIUM. NOTA 5: Puede ser producido por una sobrecarga en la salida, si es así, el equipo, periódicamente, revisará...
Page 100
por un fallo en la regulación del equipo. En caso de persistir este problema cambiar por un equipo nuevo para comprobar si se trata de una sobrecarga en la salida o es un fallo del equipo. NOTA 6: Puede ser producido por un fallo del equipo el cual suministraría más voltios de los parametrizables a la salida, una mala configuración de los parámetros del equipo o por la conexión de una batería de más voltios.
13. NORMATIVA El EDT-150-5191 es un producto con marcado CE, que cumple las directivas indicadas a continuación: Baja tensión Nivel Norma Directiva europea de baja tensión 73/23/CEE-93/68/CEE une-en 50178 (98) Perturbaciones Radioeléctricas Nivel Norma Emisiones conducidas en terminales de alimentación...
Page 102
Grado protección IP IP20 UNE EN 20324 Grado protección IK IK05 UNE EN 50102 Vibración Clase 2.3 ETSI EN 300 019-2-2 Caída Clase 2.3 ETSI EN 300 019-2-2 Climáticos Nivel Norma Calor húmedo 40ºC/ 93%/ 4 días UNE EN 60068-2-78 Calor seco 70ºC/16h UNE EN 60068-2-2...
14. ETIQUETADO: El cargador EDT-150-5191 va identificado mediante una etiqueta modelo situada en el frontal del equipo. Esta etiqueta soporta un test de marcas y la hace altamente resistente al borrado (soporta ser frotada con el disolvente hexano durante al menos 15 segundos).
El embalaje individual se realiza en caja de cartón con plástico de burbujas y retención mediante 2 bolsas de espuma Insta pack. El producto se compone se las siguientes partes: • Cargador EDT-150-5191 • Conector hembra de 4 polos para la entrada de red •...
Fuera de su embalaje, es un producto bastante robusto en general, aunque puede dañarse con golpes o caídas. 15.1.3 Transporte: El EDT-150-5191 no requiere de un proceso de transporte específico. El envío se realiza en cajas individuales. • Antes del envío todos los equipos se han verificado funcionalmente •...
A continuación, deberá realizarse una inspección visual comprobando lo siguiente: • La integridad del embalaje. • Que está debidamente precintado • Que tiene la documentación de envío correcta En caso de desperfectos notificarlo rápidamente a PREMIUM S.A, preferiblemente adjuntado fotografías de detalle. MA-5191A 21-10-2021 102 / 110...
15.3 ALMACENAMIENTO: El cargador EDT-150-5191 admite ser apilado hasta en 8 cajas con unas condiciones indicadas seguidamente, aunque la severidad reduce el tiempo máximo de almacenaje. Para almacenajes prologados, debido a la degradación de algunos componentes por la falta de uso, se deberá...
16. INFORMACIÓN MEDIOAMBIENTAL: Premium S.A., a fin de proporcionar un nivel protección aceptable para las personas y los bienes, y teniendo en consideración las recomendaciones aplicables al respeto del medioambiente, diseña y fabrica sus productos de acuerdo con el principio de seguridad integrada, basado en los siguientes criterios: •...
17. GARANTIA PREMIUM S.A, salvo acuerdo en contra, garantiza al Cliente que la fabricación de los Equipos estará libre de defectos durante el plazo de 2,5 años, a contar desde la fecha de entrega al Cliente. Si se detecta cualquier defecto, el fabricante podrá...
18. ANEXOS: 18.1 Anexo A: Curvas de rendimiento para EDT-150-5191: En la siguiente figura se muestra la curva de rendimiento del cargador EDT-150-5191 aplicando carga únicamente en la salida 1. Output Power [W] Figura 28. Gráfica rendimiento EDT-150-5191 En la siguiente figura se muestra con más detalle el rendimiento del cargador par las potencias superiores a 20W.