Table Of Contents; Description/ Construction Of The Cables; Sizing Guide; Inspection - Warmup NAMSR-5W-120 Installation Manual

Table of Contents

Advertisement

TABLE OF CONTENTS

Sizing Guide...................................................................2
Inspection......................................................................2
Warning ........................................................................3
Design............................................................................3
Before Installation........................................................4
DESCRIPTION
Warmup NAMSR cables are intended for use on
all types of roofs, including rubber, metal, clay
and asphalt shingles.
They are available in pre-terminated plug-
in kits (NAMSRK) or available for purchase in
various spool lengths and terminated on-site
(NAMSR). The kits are provided in 6, 12, 18, 24,
50, 75 and 100 foot lengths which include a
factory sealed power connection with 30 inch
power cord and plug and a factory sealed end
termination.

SIZING GUIDE

Length (ft)
250' or 1000'
250' or 1000'
6
12
18
24
50
75
100

INSPECTION

1. Open package and visually check for breaks or nicks in the cable jacket. File claim with carrier if any damage
is found.
2. Never energize the cable when it's coiled or on a reel. Test only when it is laid out straight.
3. After removing the cable from the carton or wrapping, check the insulation resistance of the unit from buss
wires to braid with a 2500VDC megger to assure the cables have not been damaged during shipping and
handling.
ELECTRIC SHOCK HAZARD. Verify insulation resistance is 20 megohms or greater before installing.
Contact Warmup if cable is less than 20 megohm.
CONSTRUCTION OF ROOF & GUTTER DE-CING CABLES
Service voltage
Normal cable width (in/mm)
Normal cable thickness (in/mm)
Cable bus wire gauge (AWG)
Cold lead length (in/mm)
Min. Circuit breaker size (Amps)
Max. Exposure Temperature
Heating Cables
NAMSR-5W-120
NAMSR-5W-240
NAMSRK-6FT with plug
NAMSRK-12FT with plug
NAMSRK-18FT with plug
NAMSRK-24FT with plug
NAMSRK-50FT with plug
NAMSRK-75FT with plug
NAMSRK-100FT with plug
Service...........................................................................5
Control of Roof & Gutter Cable.....................................5
Drawing Your Plan........................................................6
Installation..................................................................7-8
Accessories....................................................................9
Warranty.......................................................................10
Wattage per Linear
°
Foot @ 50
F
5
5
5
5
5
5
5
5
5
2
110-120V, 220-277V
0.42 (10.6)
0.23 (5.8)
16
35 (900)
15
185°F
(85°C)
Wattage per Linear
°
Foot @ 32
F
7
7
7
7
7
7
7
7
7