EUTECH INSTRUMENTS OAKTON 35 Series Instruction Manual

Multi-parameter tester

Advertisement

Quick Links

Thank you for selecting our Multi-Parameter Testr. This manual serves the following (3) models:
• PCTestr 35 (Eutech PCTEST35-01X441504 / Oakton 35425-00)
pH / Conductivity / Temperature
• PTTestr 35 (Eutech PCTEST35-01X441505 / Oakton 35425-05)
pH / Total Dissolved Solids / Temperature
• PCSTestr 35 (Eutech PCSTEST35-01X441506 / Oakton 35425-10)
pH / Conductivity / Total Dissolved Solids / Salinity / Temperature

Getting Started:

Your instrument has been factory calibrated and usually works well out of the box. However, after
best accuracy.
Your Testr begins in the measuring mode that was previously used. Just prior to measurement or
when switching modes, you will see the setting associated with each parameter i.e.) pH (buffer
group selected), Conductivity (Auto), TDS (factor), Salinity (unit of measure).

Setup:

Your Testr allows customization of various settings. To access the setup mode:
1.
With the Testr off, keep the
2.
Press
menu.
3.
Press
*IMPORTANT* It is necessary to save your Parameter and System
changes in order for them to take effect.
1.
When you are finished making your desired changes, press both
time and keep them pressed until you see "SA" (Save) on the display.
2.
With the primary display "SA" and secondary display "YES", press
changes. The instrument will resume measurement mode with new setting(s).
64
INSTRUCTION MANUAL
MULTI-PARAMETER TESTR 35 SERIES
pH / Conductivity / TDS / Salinity / Temperature
Part of Thermo Fisher Scientific
extended periods of non-use, it's best to remove the sensor cap and soak the
sensor (pictured here) in warm tap water or pH buffer for 10 minutes or so. A
brief rinse with deionized (DI) water is OK, but avoid soaking or storing in
deionized water as this will shorten the pH electrode life. Prior to taking
measurements, periodic calibration with certified standards is recommended for
(Setup) will appear, then as you release
or
to choose
to enter the selected setup menu.
www.calcert.com
15
10
20
5
25
0
30
68X441601 Rev. 1 March 2010
pressed down while you press and release
,
(Parameter) will appear.
and
.
at the same
to save the
sales@

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OAKTON 35 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for EUTECH INSTRUMENTS OAKTON 35 Series

  • Page 1 INSTRUCTION MANUAL MULTI-PARAMETER TESTR 35 SERIES pH / Conductivity / TDS / Salinity / Temperature Part of Thermo Fisher Scientific 68X441601 Rev. 1 March 2010 Thank you for selecting our Multi-Parameter Testr. This manual serves the following (3) models: • PCTestr 35 (Eutech PCTEST35-01X441504 / Oakton 35425-00) pH / Conductivity / Temperature •...
  • Page 2 Note: If auto-shut off is used, changes will be automatically saved 8.5 minutes after the last change was made. Parameter Setup: Select to make changes relating to the parameters – pH, Conductivity TDS, Salinity. Note: only the PCS Testr will have all of these options.
  • Page 3  Press to scroll thru menu options or change values.  Unit rSt (Instrument reset)  PH (pH) or EC (electrical conductivity / TDS / Salinity)  CAL (calibration reset) or FCt (Reset to factory default settings)  Set A.Off (Automatic shut off after 8.5 minutes) Choose YES or NO. ...
  • Page 4 Conductivity Calibration (Automatic): For best results, calibrate with certified accurate conductivity calibration standards. Selection of multi-point calibration will allow up to three of the following values, while Single-point calibration will allow only one; choose 84 μS, 1413 μS, or 12.88 mS. Conductivity Range Automatic Calibration Value Available with...
  • Page 5 Sensor Replacement: Your instrument includes a replaceable sensor (Eutech PCSENSOR - 01X097108 / Oakton 35425-50). If the tip gets damaged or as the sensor wears over time, the entire sensor can easily be replaced. To remove the old sensor, simply twist off the ribbed collar and pull the sensor straight out.
  • Page 6 Message Indicates >75% battery life remaining 50-75% battery life remaining 25-50% battery life remaining No bars & blinking = replace batteries Calibration error, usually attempting to calibrate to a value which is out of range or under range. Broken or dirty sensor. Clean, rehydrate, and replace if necessary. Unstable pH reading Could also be due to low battery condition or sample with / Slow response...

Table of Contents