Summary of Contents for LSC LUBRIMIST PRY330

  • Page 1 LUBRIMIST MODEL “PRY330” LUBRIMIST MODEL “PRY330” Operation and Maintenance Manual ________________________________ 1740 Stebbins • Houston, Texas 77043 713.464.6266 • Fax: 713.464.9871 • 1.800.800.LUBE • www.lsc.com PART #77740220 REV 2 April 2007...
  • Page 2 LUBRIMIST MODEL “PRY330” INSTALLATION AND OPERATION MANUAL LUBRIMIST MODEL “PRY330” OIL MIST GENERATOR PART #77740220 REV 2 April 2007...
  • Page 3: Table Of Contents

    LUBRIMIST MODEL “PRY330” Table Of Contents Introduction......................... 4 Description.......................... 4 Installation........................... 5 Dimensional Diagram ......................6 Process and Instrumentation Diagram ................7 Start-Up..........................8 Operation..........................9 Maintenance........................9 Trouble Shooting ......................10 Controlling the Oil Mist....................11 General Arrangement......................13 PART #77740220 REV 2 April 2007...
  • Page 4: Introduction

    Page 4 of 13 LUBRIMIST MODEL “PRY330” Lubrimist Model “PRY330” Oil Mist Generator INSTALLATION AND OPERATION MANUAL Introduction A Lubrimist Oil Mist System is a centralized lubrication system that generates, conveys, and automatically delivers lubricant to bearings, gear boxes, chains, and sliding surfaces in various industrial machinery and equipment.
  • Page 5: Installation

    Page 5 of 13 LUBRIMIST MODEL “PRY330” Installation Location / Mounting Choose a central convenient location, allowing enough room for air, oil and drain connections. Ensure easy access to the front of the unit. Install the “PRY330” unit in an upright position and secure with four anchor bolts that are suitable for the type of foundation used ( i.e.
  • Page 6: Dimensional Diagram

    Page 6 of 13 LUBRIMIST MODEL “PRY330” Dimensional Diagram Model “PRY330” Oil Mist Preservation Generator PART #77740220 REV 2 April 2007...
  • Page 7: Process And Instrumentation Diagram

    Page 7 of 13 LUBRIMIST MODEL “PRY330” Process and Instrumentation Diagram PART #77740220 REV 2 April 2007...
  • Page 8: Start-Up

    Page 8 of 13 LUBRIMIST MODEL “PRY330” Start-Up Prior to start-up recheck all connections and ensure that all fittings are tight. Ensure that the oil mist distribution system, reclassifiers and application point connections, vents, and drains are properly installed. To Start the Lubrimist Model “PRY330”: 1.
  • Page 9: Operation

    Consult with the nearest LSC office/service center for further discussion and recommendations. 3. Replace air filter element (P/N 77-500-472) and oil filter element (P/N 77-500-487).
  • Page 10: Trouble Shooting

    Page 10 of 13 LUBRIMIST MODEL “PRY330” 4. Make an overall assessment of the “PRY330” and mist distribution system and correct obvious deficiencies and problems. Trouble Shooting 6. Check the oil level by making a visual check of the oil level sight gauge. If the oil level is below the “LOW”...
  • Page 11: Controlling The Oil Mist

    Page 11 of 13 LUBRIMIST MODEL “PRY330” Controlling the Oil Mist Lubrimist Vortex oil mist generation technology allows for maximum control and adjustment of oil mist properties. There are three basic controls: 1. The INTEGRAL AIR FILTER-REGULATOR is used to adjust the volume of air flow to the Vortex chamber which in turn controls oil mist volume.
  • Page 12 Page 12 of 13 LUBRIMIST MODEL “PRY330” 3. The AIR BY-PASS VALVE controls mist pressure without effecting oil output. Its normal position is fully closed, but by turning it counter clockwise toward “Open” more air will be added to the oil mist leaving the generator thus increasing mist pressure and reducing the oil/air ratio.
  • Page 13: General Arrangement

    Page 13 of 13 LUBRIMIST MODEL “PRY330” General Arrangement ITEM PART NO. DESCRIPTION QUANTITY 77-000-036 300 BI Mist Head 77-000-010 1000BI Mist Head U-10923-B8 Oil Level Gauge 77-500-473 Air Filter Regulator 77-500-487 Oil Filter Element 77-800-092 Reservoir Cleanout Gasket U-902-S Mist Pressure Gauge, 0-100 In H2O U-902-R Air Press Gauge, 0-100 PSI...