Page 3
1.Product Instruction CDC11 display uses the 2.4” LCD color screen features a very clear display interface, with backlight crepuscular sensor. Double side printed board, nylon buckle and ABS material shell. Good mechanical performance is ensured in a temperature range from -20° to 6°. It also features IP65 protection to water infiltration.
5. Installation instruction - Fix display and button panel on the handlebar - Adjust the angle of view in a comfortable visible position - Tighten the screws to finish the installation...
6. Button definition Button Operation Function hold 3S Nothing (In main interface) -> turn on/off usb charging function click (In setting function) -> confirm (In passwords interface) -> switch the passwords digit hold 3S Nothing (In main interface) -> Increase the lever (In setting interface) ->...
8. Board terminal cable sequence diagram 9. Q&A Why the display is not able to start up? Check the connector between display and controller. How to deal with the error code? Ask the customer care at your local dealer.
10. Error codes Error code Definition Over current protection (controller) - Check whether the connectors of 3-phase power cable and the connectors are badly connected. - If the problem is still present after re-connect the connectors, there is something wrong with the controller or motor. Controller cannot properly drive the motor - Check whether the connectors of 3-phase power cable and the power supply connectors are badly connected.
Page 12
Thank you for your attention enjoy the ride!