BIOWAIR biow 100 User Manual

Cellular regenerative unit

Advertisement

Quick Links

R
L
egeneration &
ife
USER MANUAL
CRU BIOW

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the biow 100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BIOWAIR biow 100

  • Page 1 egeneration & USER MANUAL CRU BIOW...
  • Page 2 egeneration &...
  • Page 3: Table Of Contents

    egeneration & INDEX 1. INSTALLATION AND TECHNICAL DATA ..................4 1.1. SAFETY INFORMATION ........................4 1.2. EQUIPMENT PARTS ..........................6 1.3. TECHNICAL DATA...........................7 1.4. EQUIPMENT ENVIRONMENTAL CONDITIONS ................8 1.5. SYMBOLS AND LABELLING ......................8 1.6. EQUIPMENT INSTALLATION ......................8 2. CRU BIOW OPERATION ....................... 10 2.1.
  • Page 4: Installation And Technical Data

    EC instructions and operating instructions according standard. to current standards. The company BIOWAIR TOTAL SYSTEMS S.L., as Make sure that the power supply voltage the manufacturer of this product, is responsible corresponds to the one indicated on the rating...
  • Page 5 egeneration & PRECAUTIONS Before carrying out cleaning or maintenance, the CRU Biow must be disconnected from the wall socket and/or equipment switch. It is recommended that children not be allowed to handle the CRU Biow and should be supervised by an adult. User cleaning and maintenance must not be carried out by unsupervised children.
  • Page 6: Equipment Parts

    egeneration & 1.2. EQUIPMENT PARTS Storage shelf 2. Manual ON/OFF button 3. Display 4. Supply air grille 5. Main or deflector guiding slat It has a vertical movement to direct the supply of air. 6. Filter pack Filter pack adjustment knobs 8.
  • Page 7: Technical Data

    & 1.3. TECHNICAL DATA CRU BIOW 100 CRU BIOW 60 MEASUREMENTS AND WEIGHTS MEASUREMENTS AND WEIGHTS Model description BIOW 100 Model description BIOW 60 Dimensions 102 cm x 23 cm Dimensions 60 cm x 23 cm x 26 cm...
  • Page 8: Equipment Environmental Conditions

    egeneration & 1.4. EQUIPMENT ENVIRONMENTAL CONDITIONS Ambient operating temperature: 10-40 °C Ambient storage/transport temperature: 0-45 °C Relative air humidity: 35 – 75% non-condensing Air pressure: 700-1060 hPa CRU Biow label 1.5. SYMBOLS AND LABELLING SYMBOL DESCRIPTION SYMBOL DESCRIPTION Alternating current Protective earth Protective fuse Check operating instructions...
  • Page 9 Minimumground clearance: Minimumground clearan- 850 mm ce: 850 mm Both in CRU Biow 100 and in CRU Biow 60: Direct the equipment ensuring that it always rests on the top of the support. Wall attachment Move downwards, pressing gently until it fits...
  • Page 10: Cru Biow Operation

    egeneration & 2. CRU BIOW OPERATION 2.1. START-UP • Connect the CRU Biow to an earthed power outlet. • Check that the switch is in the ON position. If not, turn the equipment on at the ON/ OFF switch located on the right side of the equipment, indicated in the image below.
  • Page 11: Quickguide

    egeneration & 2.3. QUICKGUIDE • Place the equipment at a height between 80 To change speeds, you must exit the AUTO and 150 cm. mode. • Direct the supply of air towards people (in • From this moment on, Biow can be operated bedrooms, direct it toward the headboard of autonomously, regulating itself according to the bed).
  • Page 12: Programming And Functionalities

    egeneration & 2.4. PROGRAMMING AND FUNCTIONALITIES The following table summarizes the use and functionalities of the equipment using the remote control: BUTTON DESCRIPTION FUNCTION POWER - ON / OFF The equipment must be connected to the network and the switch must be in the ON position. MANUAL It enables customized configuration, meaning the user is able to select:...
  • Page 13 egeneration & IONIZER Facilitates the activation and deactivation of the plasma ionizers. These components act as electropolarizers by changing the electric charge of the nanoparticles in the room, which promotes their elimination. In AUTO mode they will be deactivated during the night. NOTE: Some particularly...
  • Page 14: Additional Fuctions

    egeneration & 2.5. ADDITIONAL FUCTIONS The following table summarizes the use and functionalities of the equipment using the remote control, pressing the indicated buttons for 3 seconds. It will display 3 pollution sensor measurements depending on the molecular weight: PM1 –...
  • Page 15: Night Mode

    egeneration & 2.7. NIGHT MODE 2.9. WIFI PROGRAMMING MODE The CRU Biow has an optical sensor that The programming mode, identified with the measures the amount of light in the room where WIFI symbol, allows 100% customization of the equipment is. When the CRU Biow operates the CRU Biow functionality in within specific in night mode, it will operate normally, but the time slots, as well as controlling or modifying...
  • Page 16: Display

    egeneration & 2.10. DISPLAY Thermal treatment External temperature Operating mode (Heat mode) reader Ultraviolet WIFI Timer light B l o o d P o l l u t i o n R i s k P M 2 5 Speed Infrared Ionization Filter pack...
  • Page 17 egeneration & The following is an explanation of each icon on the display: Indicates the temperature of the room, shown in the central part External temperature reader of the display. Indicates that thermal treatment has been activated, which in turn, enables the functionality to vary the room temperature using the Thermal Treatment Heat + and - buttons in a range from 16 ºC to 32 ºC.
  • Page 18: Safe Equipment Shutdown

    egeneration & 2.11. SAFE EQUIPMENT SHUTDOWN The equipment can be safely shut down by pressing the POWER button on the remote control. The display will then turn off and the equipment will stop operating. After this step, flip the switch to the OFF position on the right side of the CRU Biow.
  • Page 19 1000 W/h in the CRU Biow 100 and 500 W/h in minutes and will then be activated and the CRU Biow 60, which is also an economical way...
  • Page 20: Biow App - On Demand Programming

    egeneration & 3. 3. BIOW APP - ON DEMAND PROGRAMMING 3.1. BIOW APPINSTALLATION APP Biow connection watch video 1. The equipment is powered on. 2. Access the Biow application (by 3. After logging into the Biow application downloading it from the App Store or Play Click on the “+”...
  • Page 21 egeneration & 4. Press the UV button for three seconds 5.Press the blue “Go to WiFi Settings” icon or follow the procedure below on the mobile to From the remote control of your CRU Biow, until be used: a crossed out, flashing WIFI symbol appears on the screen.
  • Page 22 egeneration & 6. The WIFI symbol of the display will keep 7. Once the Biow network appears flashing You must connect to it. After a few seconds a This will mean that it is providing a WIFI network. message similar to this will display: “Your current After a while, the “Biow”...
  • Page 23 egeneration & 8. Return to the application and select 9. Once this process has been carried out, the application will display “Start search” option (gray icon). After that, the available networks will be displayed. Select various messages in this order: Verifying link..., the network you are interested in and the Connecting to HTTP service...
  • Page 24 egeneration & 10. After a short period, the equipment 11. You can start now will be connected by WIFI, and you will see on Program your Biow CRU in a fully personalized the Biow display that the WIFI symbol is no way and monitor its activity from the Biow APP.
  • Page 25: On Demand Programming

    egeneration & 3.2. ON DEMAND PROGRAMMING 3. Once this button has been pressed, We will explain to you below how to carry out a menu will appear where the operating mode a 100% personalized programming through the of the CRU Biow can be selected, as well as the Biow APP.
  • Page 26: Cleaning And Maintenance

    For correct operation of the equipment, the Biow CRU must be maintained according to the instructions in this guide. • Biowair Total Systems S.L. is not responsible for any failure or damage caused by the CRU Biow if the maintenance described in this user manual is not carried out.
  • Page 27: Filter Pack Cleaning And Replacement

    IMPORTANT The filter pack change indicator will be shown on the screen, although the CRU Biow will continue BIOWAIR TOTAL SYSTEMS to work normally. only guarantees the effectiveness of the BIOW equipment using filter packs supplied by the manufacturer.
  • Page 28: Filter Pack Maintenance

    egeneration & 4.3. FILTER PACK MAINTENANCE The filter pack must be replaced as indicated in the previous section of this manual. Among the consequences of not changing it would be a drop in air flow speed, the release of unpleasant odors due to the activated carbon filter being saturated, or not moving enough air to ensure comfort in the thermal stabilization system in heat mode.
  • Page 29: After-Sales Service

    Please indicate the serial number of the equipment in the email subject. Mobile: +34 985 87 93 45 ATTENTION BIOWAIR TOTAL SYSTEMS S.L BIOWAR TOTAL SYSTEMS, S.L. is not Polígono Industrial Roces responsible for equipment repaired C/ Michel Faraday nº 75, naves 9 y 10 33211 Gijón.
  • Page 30: Guarantee

    • No equipment will be returned to BIOWAIR that is to say that it is a manufacturing non- TOTAL SYSTEMS without a coded GOODS conformity. The user must inform BIOWAIR...
  • Page 31: Recycling

    egeneration & 6. RECYCLING The CRU Biow has been designed to care and protect for many years, and for this reason it comprises top quality, unalterable natural materials such as aluminum, steel, and silicon, which are 100% recyclable. This symbol means that, within the European Union, the product must be subject to separate collection at the end of its life cycle.
  • Page 32: Frequently Questions

    egeneration & 7. FREQUENTLY QUESTIONS CRU does not work. Check that power is supplied to the equipment, that the general power button, located on the bottom right, is in the ON position and that the remote control has the battery inserted correctly. The screen displays 999.
  • Page 33 Biowair Total Systems, S.L. is the legitimate owner of all intellectual and industrial property rights inherent in the BIOW brand, including image ri- ghts, photos, trademarks, models, designs and patents, as well as the entire contents of its website and catalogs, all these rights being protected by national and international laws and treaties on copyright, intellectual and industrial property.
  • Page 34   DECLARACION DE CONFORMIDAD DE MARCADO CE     CE MARKING DECLARATION OF CONFORMITY        El que suscribe:  We, the undersigned:    BIOWAIR TOTAL  SYSTEMS S.L. CIF B‐ 33998980  C/ Michel Faraday 75, Naves 9 y 10       33211 — Gijón  Asturias — España    Declara, bajo su responsabilidad, que el producto:  We declare, under our responsibility, that the product:  Unidad de tratamiento integral del aire, identificado en placa de características como:  Integral air treatment unit, identified in technical plate as:    DATOS TÉCNICOS  MODELO/MODEL  POTENCIA/POWER  1000 W BIOW 100    230V/50Hz  IP 21  500 W  BIOW 60    Ha sido fabricado conforme a las especificaciones técnicas del producto y cumple todas las normas vigentes, en particular:  It has been manufactured according to the technical specifications of the product and it conforms in all respect to the  relevant standards and regulations in force and especially to:    Seguridad:  EN 60335‐1:2012+AC:2014+A11:2014  Safety: ...
  • Page 35 REGENERATION UNIT CELLULAR AND REST Biow transforms a physical space into a regenerative environment or BiowSpace that also provides an optimal rest ELECTROPOLARIZATION UV TREATMENT PLASMA ENERGY MICROCIRCULATION AND RECIRCULATION NANOFILTERING WIFI CONTROL THERMAL & BIG DATA TREATMENT CONTINUOUS 24 / 7 LAMINAR FLOW LONG LIFE LEVITATION RESPIRATORY...
  • Page 36 BIOWAIR TOTAL SYSTEMS S.L. Polígono Industrial Roces C/ Michel Faraday nº 75, naves 9 y 10 33211 Gijón. Asturias SPAIN www.biow.es biow_oficial biow oficial biow oficial Ref.: 290721...

This manual is also suitable for:

Biow 60Cru biow

Table of Contents