4.Preparation For Use; 5.Operations - Zenisu Keisoku ZS-6103EG-F1 User Manual

High-speed gp-ib extender
Table of Contents

Advertisement

4.PreParation for Use
Connection of cable and others are as follows;
(1) Connect the oPtical fiber cable with each other. Make a cross-connection between "IN" and
"OUT". The cable connected to "OUT" of the one device should be connected to "IN" of the
other one.
(2) Connect the GP-IB cable.
(3) Connect the Power code to DC.
(4) Confirm that POWER LED is lit on and other LEDs are not lit.
5.OPeration
This unit conducts uerial-Parallel(u/P) conversion and Parallel-uerial(P/u) conversion using CODEC,
to ensure that cable can transmit the Parallel signal tyPe of GP-IB as bit serial.
Error correction function for serial data transmission between cables is imPlemented to increase
data transmission reliability.
Without identification marking
OPtical fiber cable
With identification marking
AC adaPter
DC5V 1A or more
Center Plus
ExamPle of F1(FC) tyPe, F5 tyPe
5
AC adaPter
DC5V 1A or more
Center Plus

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs-6103eg-f5

Table of Contents