Model: M5261-1/100, M5261-2/100
Art.no.
Model
77 590 57
1x60W
77 590 58
2x60W
insTALLATiOn
1. Make sure that the power is disconnected before
installation.
2. The fitting is mounted directly on the ground. The
fitting must be mounted on flat concrete ground
surface.
3. Be sure of the exact mounting position before
drilling the holes.
4. incoming cable is connected to the terminal block
inside the fitting.
5. The sealing ring of the fitting must be intact, for
the protection class ip 44 to be valid.
AssEMBLY
1. disassemble the front cover and pC diffuser of the
fitting.
2. Connect the power cables properly with the fitting.
3. Mount the fitting directly to the ground by using
the ground plugs and screws provided.
4. insert suitable light bulb (see suitable Lamp below).
5. reassemble the pC diffuser and front cover of the
fitting.
Malmbergs Elektriska AB, pO Box 144, sE-692 23 Kumla, sWEdEn
phone: +46 (0)19 58 77 00
dims WxHxd (mm)
180x1000x180
180x1000x260
Fax: +46 (0)19 57 11 77
suiTABLE LAMp
nOTE: Always disconnect the power before changing
the bulb.
1. incandescent or halogen lamp.
2. Carbon thread lamp. nOTE: Wait a minute before
turning the light on after changing the lamp.
3. Energy saving lamp.
(Max wattage and cap, see Technical data below).
nOTE
1. The cable must not be shortened or altered in any
other way.
2. The lamp shade must not be covered.
3. The rating label must not be removed.
TECHniCAL dATA
Incandescent lamp:
Max 60W, E27.
Energy saving lamp: Max 15W, E27.
Terminal block 3x2.5 mm².
Connection:
ip 44.
Protection class: