Advertisement

Quick Links

Product Notes
Network 9000 Model 119R Redundant AC
Power Input Modules
Xyplex Networks, Incorporated
295 Foster Street
Littleton, MA U.S.A. 01640
451-0054C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 119R and is the answer not in the manual?

Questions and answers

Summary of Contents for Xyplex 119R

  • Page 1 Product Notes Network 9000 Model 119R Redundant AC Power Input Modules Xyplex Networks, Incorporated 295 Foster Street Littleton, MA U.S.A. 01640 451-0054C...
  • Page 2: Table Of Contents

    MAXserver and LANBUS are trademarks of Xyplex Networks, Inc. All rights reserved. No part of this publication may be reproduced without the prior written consent of Xyplex Networks, Inc. The information in this document is subject to change without notice and should not be construed as a commitment by Xyplex Networks.
  • Page 3: Product Prerequisites

    9000 fifteen-slot chassis, including classic and switchplane chassis. (Order codes are listed on the last page.). The 119R AC Power Input Module provides the means to ensure uninterrupted service, in the event of a power system failure, when an AC circuit within a facility fails, or when an AC Power Input Module fails.
  • Page 4 (the bottom slot of the Network 9000 chassis), the other in slot 10. Xyplex Networks recommends that you order 2 or 4 power supplies for the chassis to ensure power supply redundancy.
  • Page 5: Safety Considerations

    Figure 2 shows the location and purpose of all controls and LED indicators on the Network 9000 Redundant AC Power Input Module. Ethernet Address Label I/O Connector Redundant 08-00-87-xx-xx-xx 11/5230V~ 119R 12/6A 50-60Hz Power Cord Connector I/O Connector Location (Supports Network 9000 Type 1 On/Off Switch communication options.)
  • Page 6: Power Supply Planning Considerations

    Network 9000 Chassis Hardware Installation and Maintenance Guide: P/S 3, P/S 4, P/S 2, and P/S 5. Figure 3 shows this order. slot 15 Xyplex slot 14 Second Pair. Network 9000...
  • Page 7: Connecting Ac Power

    Connecting AC Power Perform the following steps to connect AC power: a . Set the power switch located to the left of the AC power cord connector (socket) on the rear of both power input modules to the OFF position. b.
  • Page 8 Table A. Product Support for Full Redundancy. Processor Software Revision Firmware Revision Module Type 480000 (H) 4B0000 (K) 4B0000 (K) 430000 (C) 430000 (C) 520000 (S) 520000 (S) 430000 (C) 410000 (A) Use the SHOW UNIT command to determine the software and firmware revision. All processor modules should load normally, after installing the replacement AC power input module.
  • Page 9: Specifications

    Product Name and Description Order Code Classic Network 9000 Redundant Fifteen-Slot Chassis N9-9015-022 (includes two Redundant AC Power Control Modules) Switchplane Network 9000 Redundant Fifteen-Slot Chassis N9-9115-022 (includes two Redundant AC Power Control Modules) Redundant AC Power Input Module (spare) N9-000-119R...

This manual is also suitable for:

N9-000-119