Migali C-RB24-NG Operating Instructions Manual

Migali C-RB24-NG Operating Instructions Manual

Gas radiant countertop char broilers

Advertisement

Quick Links

Gas Radiant Countertop Char Broilers
Operating Instructions
Before you begin, please read these instructions carefully to use
this product correctly, to make the product perform ideally, and to
avoid hazards.
Models : C-RB24-NG(LP) / C-RB36-NG(LP) /
C-RB48-NG(LP)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C-RB24-NG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Migali C-RB24-NG

  • Page 1 Gas Radiant Countertop Char Broilers Operating Instructions Before you begin, please read these instructions carefully to use this product correctly, to make the product perform ideally, and to avoid hazards. Models : C-RB24-NG(LP) / C-RB36-NG(LP) / C-RB48-NG(LP)
  • Page 2 Dear customers and users: Thank you for purchasing our products. In order to be able to better use this product, please read these instructions carefully before any operation, and follow the guide, to avoid any unnecessary trouble during using. Please keep this instruction manual in a safe place for convenient reference and operation.
  • Page 3 Gas Radiant Countertop Char Broilers Installation, Operation and Maintenance Guide Contents 1. Safety Protection ..................- 3 - 2. Brief Introduction ..................- 4 - 3. Manufacturer's Authority and Responsibility........- 4 - - 2 -...
  • Page 4: Table Of Contents

    4. Parameter Specifications ................ - 5 - 5. Transport and Storage ................- 8 - 6. Installation and Debugging ..............- 9 - 7. Safety Notices and Precautions ............- 13 - 8. Operating Instructions ................- 14 - 9. Cleaning and Maintenance ..............- 18 - 10.
  • Page 5 the product for normal use. Place the product in a reasonable position. Regarding related matters of gas, customer should execute the requirements of local gas supply sector; If you smell a gas leak, turn off the gas valves immediately and call the gas company;...
  • Page 6: Parameter Specifications

    Be repaired or changed by unauthorized technicians; Use the spare parts or accessories provided by non-manufacturer; Accidents caused by force majeure; Not strictly comply with related guide of instruction by any reason. 4. Parameter Specifications 4.1、Outline Dimensions(inch) C-RB24-NG(LP) - 5 -...
  • Page 7 C-RB36-NG(LP) - 6 -...
  • Page 8 C-RB48-NG(LP) - 7 -...
  • Page 9: Transport And Storage

    4.2、Gas Supply and Burner Information The minimum supplied gas pressure regulator is factory set at 4”Natural Gas W.C, and 10”L.P. Gas W.C. The external thread of product’s intake-tube is 3/4 inches. <Table 1> #of burners Intake-tub Total Per BTU Nozzle Model and control e pressure...
  • Page 10: Installation And Debugging

    rainproof measures should be taken. 6. Installation and Debugging Any erroneous installation, adjustment, refit, overhaul or maintenance may cause property damage or personal injury. All this work shall be completed by authorized and licensed technicians, otherwise the manufacturer has the right not to provide warranty service;...
  • Page 11 Be sure to install supporting legs before using, and do not tear up any label or logo before the normal using; Please read these instructions carefully before installation and operation. Please contact your local agent if you have any questions; The charbroiled shall be installed on a level, solid, non-skid and incombustible surface, and placed in a well-lighted work area with waterproof, and away from children and customers;...
  • Page 12 the support; Supplied gas pressure regulator is factory set at 4”Natural Gas W.C, and 10”L.P. Gas W.C; The equipment can only be placed on the nonflammable counter top, and keep a distance of at least 6 inches(152mm) to equipment’s both sides and back, and keep a distance of at least 4 inches(102mm) to the bottom;...
  • Page 13 ●Remove counter top plate, and needle type pressure joint screw arbor (Fig.1), then slip rubber tube of pressure gauge over needle type pressure joint; ●Start the equipment in accordance with the instructions, measuring gas supply pressure (dynamic pressure) in the work state; ●Access to the equipment if measured data within the limits of table 1, otherwise, you will need to adjust gas pressure regulating valve or contact gas supplier to bargain;...
  • Page 14: Safety Notices And Precautions

    7. Safety Notices and Precautions Warning! For your safety, do not place petrol and other flammables nearby. Please keep clean and free of flammables surroundings. (Read ANSI Z83.14B, 1991 for reference) Warning! Any erroneous installation, adjustment and refit may cause property damage or personal injury and maintenance failure. Read the instructions carefully before installation and using.
  • Page 15: Operating Instructions

    The use of attachments not recommended or sold by the manufacturer may cause fire, personal injury, even death; Do not use out of doors; The equipment is used for barbecue, not available for any other use; The equipment does not contain any user-serviceable parts. Dealers or technicians will repair it.
  • Page 16 8.1、Lighting the pilot light Turn the control valve at the position of “0”(Fig.2), make sure all knobs are in the close state. Light and hold an ignition source at the pilots. The pilot light may not be lighted immediately, for existing gas in the pipe. Wait a minute, the pilot light will be lighted after the gas extinguished.
  • Page 17 Fig.2 Fig.3 Fig.4 Make sure air circulation at the bottom of equipment; Do not use fan or air-conditioning blowing at the flame, in order to avoid extinguishing flame, and cause safety accidents; Install the matched cooking fume exhauster according to the local regulations over the char broiler;...
  • Page 18 is normal, and it will be eliminated after the power up to the maximum for burning an hour. One side of grate with grease trough (Fig.5), and on the other side of grate is flat (Fig.6), users can choose a side according to demand, users also can adjust grate’s gradient according to demand (Fig.7).
  • Page 19: Cleaning And Maintenance

    the gas source, exchange the corresponding pressure maintaining valve which installed on air intake. See 2 in P17. 8.6、Adjust air input Remove control panel, unscrew damper solid screw(Fig.9), revolve damper left to right (Fig.10), meanwhile, observe flame and adjust an appropriate opening degree.
  • Page 20 corrosive detergent! Warning: Before cleaning, all control valves must be turned off. Strictly follow the lighting instructions to work again after cleaning! Warning: Wait for the equipment cool down before your cleaning! Cut off the gas source as not in using; If the equipment is not used for a long time, clean the surface by wiping it with a soft cloth and place it in a well-ventilated area;...
  • Page 21 detergent Turn off the valves when not in use; Control panel daily Wipe panel and control valve knob with mild detergent. Caution: Wear insulated gloves when handling grates or radiants, in order to prevent possible burns! 1.Take out grates and radiants; 2.Clean grease other...
  • Page 22: Troubleshooting

    Remove grate until the equipment Char Grate cools down. Take off char grate back Back Support support brace, clean grease and daily/as need Brace other crumbs. Then daub lubricants. Reinstall after cleaning. Pull out catch tray from front body until the equipment cools down. Clean grease and other crumbs.
  • Page 23 pilot light in pipe gas supply dept. but not the 2.The main fire nozzle 2.Dredge nozzle main fire occlusion 3.Gas control valves have 3.Change problems control valves 4.The pilot light and the main 4.Adjust fire’s distance is too far distance of them 5.Adjust the height 5.Flame is too low of the pilot light...
  • Page 24: Spare Parts

    opening degree 4.Turn down valves 4.In the peak of using gas, flow. Turn it up sources of gas float heavy after the peak The problems mentioned above are only for reference. If any fault occurs, please stop using, and contact technicians to check and repair. Safety first, turn off the power and gas supply before maintenance.
  • Page 25 Fig.11 <Table 4> Matters Component Dimensions Remark Code name (mm)/Model - 24 -...
  • Page 26 Adjustable C-RB24-NG(LP)\3 301110001 φ41.5*100 steel leg 6-NG(LP)\48-NG( 21105001001 507*620*26.5 C-RB24-NG(LP) Catch tray 21105002001 807*620*26.5 C-RB36-NG(LP) 21105003001 1107*620*26.5 C-RB48-NG(LP) C-RB24-NG(LP) Galvanized 301080002 C-RB36-NG(LP) flange face nut C-RB48-NG(LP) C-RB24-NG(LP) Galvanized flat 301082001 φ6*φ10 C-RB36-NG(LP) grommet C-RB48-NG(LP) Galvanized C-RB24-NG(LP)\3 301081006 ST4.8*12.5 American 6-NG(LP)\48-NG(...
  • Page 27 (NG) LP50 C-RB48-NG(LP) Pilot light C-RB24-NG(LP) 301040007(L A18 nozzle(LP) 301030001 AP7-1 C-RB36-NG(LP) valve-single C-RB48-NG(LP) unit C-RB24-NG(LP) φ 4.7*0.6 21102001030 Air input pipe C-RB36-NG(LP) L=400 C-RB48-NG(LP) C-RB24-NG(LP) Pilot light head 301170015 C-RB36-NG(LP) stator C-RB48-NG(LP) C-RB24-NG(LP) 301060003 Pilot light head A73007/TiPφ4.7 C-RB36-NG(LP)
  • Page 28: Accessories List

    C-RB36-NG(LP) C-RB48-NG(LP) pressure C-RB24-NG(LP)\3 301030014 4”-10” maintaining 6-NG(LP)\48-NG( 24”counterto 301070001 Φ26-503*648 C-RB24-NG(LP) valve p char broiler 36”counterto 301070002 Φ26-803*648 C-RB36-NG(LP) intake-tube p char broiler 48”counterto 301070003 Φ26-1113*648 C-RB48-NG(LP) intake-tube p char broiler 21205001002 600*640*203 C-RB24-NG(LP) intake-tube surround 21205002002 900*640*203 C-RB36-NG(LP)
  • Page 29 A18 Orifice 2 pieces 3 pieces 4 pieces instructions 1 piece 1 piece 1 piece Notice: 1、Pressure maintaining valve connects with air intake, must be installed by authorized and licensed technicians, to assure interface tightness. 2、Screw the hex nut (Fig.12) before connect air intake, ensure gas mark (Fig.13) on the plastic core whether match with connected gas source, if not, then pull out the plastic core and change another head, insert it again.
  • Page 30 Our products have the advantages of good durability and low maintenance charge. But to update some components and necessary maintenance, can prolong life length of the products. Contact the dealer for assistance. In order to avoid confusion, please follow the format in figure 11 and table 4. - 29 -...
  • Page 31 Migali Industries, Inc. Trusted Since 1955 516 Lansdowne Ave Camden, NJ 08104 Service Call: 800.852.5292 Service Email: warranty@mgiali.com - 30 -...

This manual is also suitable for: