XtendLan DPA-MRMDS Setting Manual

Advertisement

DPA-MRMDS setting manual
Use the DPA-MRMDS you can extend the Door Station or CCTV camera up to 4, in one
building. By using the DPA-MRMDS users can receive video call from each Door Station of monitor
each CCTV camera. Read and follow this instruction to set up the system

1. Testing map

2. Ports and Specifications

VD/IN: Video input from Door Station
■ VD/OUT: Video output to the Monitors(or Distributors)
■ VD/NT: Video output to the Guard Unit
■ VD/2ND: Video output for other usages
■ CAM-1: Video input from Camera NO.1(or the second Door station)
■ CAM-2: Video input from Camera NO.2(or the third Door station)
■ CAM-3: Video input from Camera NO.3(or the fourth Door station)
■ DC 12V: DC output for the Cameras
■ SWITCHER: to set the address for the DPA-MRMDS, if there is only one MR- MDS
used in the building, set to 1
■ A1,P-,D1,D2: connect to the A1,P-,D1,D2 of the Door Station
■ P+, P-: connect to the power supply

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DPA-MRMDS and is the answer not in the manual?

Questions and answers

Summary of Contents for XtendLan DPA-MRMDS

  • Page 1 DPA-MRMDS setting manual Use the DPA-MRMDS you can extend the Door Station or CCTV camera up to 4, in one building. By using the DPA-MRMDS users can receive video call from each Door Station of monitor each CCTV camera. Read and follow this instruction to set up the system 1.
  • Page 2 3. Settings on the Door Station(s) Settings must be made to all the Door Stations which connected with the MR- MDS. � Step.1 Enable the DPA- 2 0 - 0 8 0 6 : 1 8 MRMDS 1. W hen t he D oo r St at ion i s on standby mode, press #8009 on the [ 8 0 0 9 ] keyboard, then input the password(the...
  • Page 3 Step.2 Modify the settings of DPA-MRMDS [ 9 ] A d v a n c e d C o n f i g 1. After enable the DPA-MRMDS, the - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 .
  • Page 4 Example 1: > > [ 9 ] [ 5 ] . 4 M R - M D S The system is using one DPA-MRMDS, and connected with one Door Station A d d r [ 1 ] and one CCTV camera. The Door...
  • Page 5 Wiring example for C5-system: DPA-5C-MC RVV2*1.0mm DPA-5C4 DPA-5C-MC DPA-5C4 CAT5 DPA-5C-DC DPA-MRMDS DC 12V A1 P- D1 D2 P+ P- DPC-536 DPC-536 DPC-536 DPC-536 MR-MAIN-V5 MR-MAIN-V5 Connect with electromagnetic lock Connect with electronic lock...

Table of Contents