  • Page 1 MTX-StarWater Software User Guide www.webdyn.com...
  • Page 2: Table Of Contents

    2.1.15 SETPARAM: Modifying Configuration Parameters ..........11 2.1.16 GETPARAM: Read Configuration Parameters............11 2.1.17 Configurable Parameters ..................12 2.2 Configuration Via App ......................13 Sales Contact ........................14 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 3: Quick Start

    1.3 Enable/Disable LEDs To increase the autonomy, the equipment has the LED indicator lights disabled by default. To enable them, the jumper must be set to LEDS ENABLE. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 4: Bus Connection

    If the LEDs are enabled, the Status LED will blink, indicating that the equipment is on, as well as the Read LED while reading the meters and the Net and Upload LEDs while connecting to the platform and sending of data. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 5: Configuration

    The microprocessor firmware is a *.cyacd file with x lines of text (ASCII). This file must be transmitted from the platform to the equipment (before starting the physical firmware update process) to be stored in the non-volatile memory of the modem (BG95-BG95). AT^MTX=UPDATEFW OK/ERROR contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 6: Deletelogger: Clearing The Storage Memory

    <LB>: number of bus reads executed so far <LA>: accumulated value of the duration in seconds of the bus reading phase <LI>: number of smart reads (activated after collisions) contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 7: Delstatusapp: Clear Application State Variables

    <RSRQ>: reference signal received quality (use AT+QCSQ) <SNR>: signal to noise ratio (use AT+QCSQ) <ECL>: Coverage Enhancement Level (AT+QCFG = ”celevel”) <CELLID>: cell ID (use AT+QENG = ”servingcell”) contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 8: Norequest: The Platform Does Not Require More Communications

    * For backward compatibility, if the mask, wDay and mDay fields are set to 0, it is interpreted as a request for A/A+ frames every day of the month and of the week. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 9: Setsendwindow: Send Window Settings

    2.1.12 GETREADWINDOW: Reading Settings From a Reading Window The team will return a JSON with the configuration of the requested reading window. AT^MTX=GETREADWINDOW,<id> {“data”: { “RW”:<id>, “EN”:<en>, “ST”:<start>, “ED”:<end>, contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 10: Getsendwindow: Reading The Configuration Of A Send Window

    Be careful that the transmission window will coincide with the reading window. Tip: if transmission window matches reading window, suspend transmission window until reading window ends. Check last pages of document (test2). contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 11: Setparam: Modifying Configuration Parameters

    2.1.16 GETPARAM: Read Configuration Parameters The equipment will return this configuration parameter stored in memory. AT^MTX=GETPARAM,<paramName> <paramValue> OK/ERROR The next section will list all the parameters available for configuration. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 12: Configurable Parameters

    Window 8 start reading (0… 23) CLAC_READWINDOWEND7 Wnd of reading window 8 (0… 23) CLAC_READPERIOD7 Window reading period (300… 84600 seconds) CLAC_READMASK7 Type of frame to read (0… 7) hex contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 13: Configuration Via App

    To avoid accidents, sensitive parameters are password protected. This password is “0000” by default, although it can later be changed to another string with a maximum of 32 alphanumeric digits. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
  • Page 14: Sales Contact

    Email: jcabezas@matrix.es District Centre, Janakpurt, 110058 New Delhi Phone: +91.1141519011 Email: purchase-india@webdyn.com PORTUGAL LusoMatrix Lda. Av. Coronel Eduardo Galhardo 7-1ºC 1170-105 Lisbon, Portugal Phone: +351.218162625 Email: comercial@lusomatrix.pt contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...