Summary of Contents for MED-EL hearLIFE AudioStream Ma070401

  • Page 1 Cochlear Implants AudioStream User Manual...
  • Page 3: Table Of Contents

    5. Care and maintenance ....................8 Maintenance ........................8 Disposal ..........................8 6. Troubleshooting ......................9 7. Technical data ......................10 Regulatory statements...................... 11 Symbols ..........................11 Guidance and manufacturer’s declaration ...............12 8. Appendices ......................14 Warranty ...........................14 Manufacturer address .......................14 9. Contact MED-EL ....................... 15...
  • Page 4: Introduction

    Introduction 1. Introduction This user manual provides information and instructions for the MED‑EL AudioStream (Ma070401), an optional battery pack cover for the SONNET and SONNET EAS series referred as SONNET series in this user manual. It includes descriptions of assembling instructions and instructions for proper care of the device.
  • Page 5: Intended Use - Indications - Contraindications

    Intended use – Indications – Contraindications 2. Intended use – Indications – Contraindications Intended use AudioStream is an optional battery pack cover that can be used with the SONNET series audio processor to stream audio content from mobile devices (e.g. smartphone) to the SONNET series audio processor.
  • Page 6: Audiostream

    AudioStream 3. AudioStream AudioStream wirelessly connects your audio processor with mobile devices (smartphone, tablet, etc.) to stream sound like a phone call or music directly to your ears without the need of intermediate accessories. For compatible Apple and Android™ devices please ®...
  • Page 7: How To Use Audiostream

    AudioStream Pairing and configuring AudioStream To stream sound via AudioStream directly to your processor, you first have to pair AudioStream. To pair your mobile device with AudioStream and configure AudioStream, proceed as follows: Download the latest AudioKey app from your app store. ①...
  • Page 8: General Precautions And Warnings

    General precautions and warnings 4. General precautions and warnings This section contains information on the safe use of your AudioStream. Please read this information carefully. Your healthcare provider or local MED‑EL representative will assist you with any additional questions you may have. AudioStream contains electronic components which require special precautions regarding electromagnetic compatibility (EMC).
  • Page 9 General precautions and warnings • Do not modify the housing, the electronics or any part of AudioStream. • Do not use AudioStream with any device other than those listed in this manual or approved by MED‑EL to ensure proper operation of AudioStream. CAUTION ⚠...
  • Page 10: Care And Maintenance

    Care and maintenance 5. Care and maintenance Maintenance AudioStream is designed for durability and reliability. Handle your AudioStream with care. • Do not drop the device. • Do not try to repair electronic parts of your AudioStream and do not try to open the device as this invalidates the warranty.
  • Page 11: Troubleshooting

    Troubleshooting 6. Troubleshooting For assistance and reporting of issues associated with this MED‑EL product or to report unexpected operation or events, contact your local MED‑EL representative. Please also refer to the applicable audio processor user manual for troubleshooting guidelines. Problem Possible cause Recommended action Pairing process failed...
  • Page 12: Technical Data

    Technical data 7. Technical data Model AudioStream (Ma070401) Dimensions4 5.9 mm (0.232 in.) 63.7 mm (2.51 in.) 37.4 mm 9.3 mm (1.472 in.) (0.366 in.) Weight • SONNET series for CI with AudioStream (including batteries): 11.5 g (0.41 oz.) • SONNET series for EAS with AudioStream (including batteries): 12.2 g (0.43 oz.) Materials Mixture of polycarbonate and acrylonitrile‑butadiene‑styrol polymer (PC/ABS) Temperature and...
  • Page 13: Regulatory Statements

    Technical data Regulatory statements Applicable in Canada only: Model: AudioStream (Ma070401) – IC: 11986A‑AS This device contains licence‑exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence‑exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
  • Page 14: Guidance And Manufacturer's Declaration

    Technical data Serial number Fragile; handle with care Temperature limit Humidity limitation Atmospheric pressure limitation Type BF (IEC 60601–1/EN 60601‑1): The surface of AudioStream, which is in contact with the user, is a Type BF Applied Part Non‑ionizing electromagnetic radiation Battery pack recommended for use with wireless accessories Moisture and dust protection acc.
  • Page 15 Technical data Electromagnetic immunity – for all equipment and systems AudioStream is intended for use in the home healthcare environment. The customer or the user of AudioStream should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment –...
  • Page 16: Appendices

    MED-EL Elektromedizinische Geräte GmbH Worldwide Headquarters Fürstenweg 77a 6020 Innsbruck, Austria Tel: +43 (0) 5 77 88 E‑Mail: office@medel.com MED-EL distributor in the U.S.: MED-EL Corporation 2645 Meridian Parkway, Suite 100 Durham, NC 27713, USA Tel.: (919) 572‑2222 Fax: (919) 484‑9229 Toll free: (888) MED‑EL‑CI (633‑3524)
  • Page 17: Contact Med-El

    Contact MED‑EL 9. Contact MED‑EL Please refer to the accompanying Contact Sheet for your local office. © 2020 MED‑EL Elektromedizinische Geräte GmbH. Document revision 1.0 (issued 11/2020). All rights reserved.
  • Page 20 MED‑EL Elektromedizinische Geräte GmbH Fürstenweg 77a, 6020 Innsbruck, Austria offi ce@medel.com medel.com...

Table of Contents