Canarm 400 Series Operation Instructions And Parts Manual

Utility blowers
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

400/800/900 SERIES
UTILITY BLOWERS
OPERATION INSTRUCTIONS AND PARTS MANUAL
READ AND SAVE THESE INSTRUCTIONS
Models:
407 through 425, 809 through 818, 809-2 through 818-2, 907,
909-7, 909, 910-8, 910, 912-9, 912, 915-10, 915, 918-13,
918, 920, 922, 925, 927, 930, 933, 936
WARRANTY
CANARM Ltd. warrants every new product to be free of defects in material and workmanship, to the extent that, within a period of one year
from the date of purchase CANARM Ltd. shall either repair or replace at CANARM's option, any unit or part thereof, returned freight prepaid, and
found to be defective.
This warranty does not include any labour or transportation costs incidental to the removal and reinstallation of the unit at the user's premises.
Components repaired or replaced are warranted through the remainder of the original warranty period only.
This warranty applies to the original purchaser-user only; it is null and void in case of alteration, accident, abuse, neglect, and operation not in
accordance with instructions.
NOTICE:
No warranty claims will be honored by CANARM Ltd. unless prior authorization is obtained.
GENERAL SAFETY
Rotating parts, (pulleys, shafts and belts) on fans should not be exposed. Where these components are not protected by ductwork, cabinets
or covers, appropriate guards should be employed to restrict exposure to rotating parts. Access doors should not be opened with the fan
operating to avoid foreign objects being drawn into the system. On initial start-up, a careful inspection should be carried out to ensure no
foreign material is present which could become airborne in the system.
Read installation and operation instructions carefully before attempting to install, operate or service Canarm/Delhi 400/800/900 Series.
Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference.
Installation or Product problems? Do not return to store of purchase.
Contact Canarm Service at 1-800-265-1833 (CANADA) 1-800-267-4427 (U.S.A.)
1-800-567-2513 (EN FRANCAIS) Monday to Friday 8:00 - 5:00pm e.s.t.
Canarm Ltd. - Corporate Head Office
400_800_900 SERIES_04_08_2022
400_800_900 SERIES_04_08_2022
400 SERIES
2157 Parkedale Avenue, PO Box 367
Tel: (613) 342-5424; Fax: (613) 342-8437
www.canarm.com
800 SERIES
Brockville, Ontario Canada K6V 5V6
hvacsales@canarm.ca
900 SERIES
Page 1 of 8
Page 1 of 4

Advertisement

Table of Contents
loading

Summary of Contents for Canarm 400 Series

  • Page 1 WARRANTY CANARM Ltd. warrants every new product to be free of defects in material and workmanship, to the extent that, within a period of one year from the date of purchase CANARM Ltd. shall either repair or replace at CANARM’s option, any unit or part thereof, returned freight prepaid, and found to be defective.
  • Page 2: Before You Begin

    #-.-$&*- %-.-%&$(' $" $-.-%&$(' !"#$% !&'()*+ ,*&-.)#/&( 0$/1*.)23456 ,") %&!' ,$" %&!' ,").* %&!' ,$".* %&!' ,$*.* $%" FIGURE 1: 400 SERIES ,$+.* ,$,.* %"* !"#$% !&'()*+ ,*&-.)#/&( 0$/1*.)23456 )"# %&!' )").# %&!' )") %&!' !" )$"., %&!' )$" ,$*.) FIGURE 2: 800 SERIES )$+.$"...
  • Page 3 400/800/900 SERIES UTILITY BLOWERS 5/16” adjusting bolt 5/16” keps nut 1/4” keps nut 5/16” Z.P washer Motor adjusting clip Motor / Motor Plate Resilient Bumper 1/4” x 3/4” Hex cap screw FIGURE 5: OPTIONAL MOTOR MOUNTING WARNING EXCESSIVE bELT TENSION IS THE MOST FREQUENT CAUSE OF bEARINg wEAR AND RESULTINg NOISE. PROPER bELT TENSION IS CRITICAL FOR QUIET EFFICIENT OPERATION.
  • Page 4: Operation

    400/800/900 SERIES UTILITY BLOWERS WARNING A gROUND wIRE MUST bE CONNECTED FROM THE UNIT CHASSIS TO A SUITAbLE ELECTRICAL gROUND. OPERATION 1. Complete the electrical connections, energize the unit momentarily and ensure proper wheel rotation. 2. Apply full power. 3. With all ducts attached, the access doors in place and the air system in full operation, measure the motor current and ensure that it is less than the rated full load motor amperage as indicated on the motor nameplate.
  • Page 5: Garantie

    Canarm Ltée. garantie que chaque nouveau produit ne comporte aucune défectuosité dans le matèriel et la main-d'oeuvre, et de ce fait, Canarm Ltée. remplacera ou réparera à son choix, tout unité ou partie de cette unité qui comporte une defectuosité, pour une période de un an suivant la date d'achat.
  • Page 6: Avant De Débuter

    SÉRIES 400/800/900 VENTILATEUR UTILITAIRE AVANT DE DÉBUTER Inspectez l’unité pour détecter tout dommage et rapporter tout dommage causé par le transport au transporteur. Vérifiez toutes les fixations, resserrez si nécessaire. Faites tourner la roue du ventilateur à la main pour assurer une rotation libre. En cas de frottement, desserrez-la ou les vis de réglages, repositionnez la roue au centre de l’arbre et resserrez les vis de réglage.
  • Page 7 SÉRIES 400/800/900 VENTILATEUR UTILITAIRE 5/16” Boulon d’ajustement 5/16” adjusting bolt 5/16” Boulon d’ajustement 5/16” keps nut 1/4” Écrou à crémaillère 1/4” keps nut 5/16” Rondelle Z.P. 5/16” Z.P washer Motor adjusting Pince d’ajustement clip pour moteur Moteur/Plaque de moteur Motor / Motor Plate Pare-chocs résilient 1/4”...
  • Page 8: Opération

    SÉRIES 400/800/900 VENTILATEUR UTILITAIRE MISE EN GARDE UN FIL DE MISE à TERRE DOIT êTRE CONNECTÉ DU CHâSSIS DE L’UNITÉ à UN SOL ÉLECTRIQUE APPROPRIÉ. OPÉRATION 1. Complétez les connections électriques, alimentez l’unité momentanément et assurez-vous que la roue tourne correctement. 2.