Quick Links

Manual

Advertisement

Table of Contents
loading

Summary of Contents for Uhlenbrock Elektronik 28000

  • Page 1 Manual...
  • Page 2: Table Of Contents

    Contents 1. Description ....................Basic Unit Part No. 28000 Add-on unit – White Part No. 28010 Two white, one red and one blue CCFL tube and one 10W Halogen flood lamp, inc. connecting cable and 2 connecting plates. 3. Technical Data..................
  • Page 3: Description

    The lighting system is powered with a normal Model railway transformer. 2. The Components Basic Unit Part No. 28000 The electronic controller, two white, one red and one blue CCFL (cold cathode fluorescent) tubes, one Halogen flood light and two end caps.
  • Page 4: Technical Data

    3. Technical Data Power consumption basic unit 28000 27 VA Power consumption add-on unit white 28010 43 VA Power consumption add-on unit colour 28020 27 VA Output voltage of the power transformer 12V-17V Max. current in connecting cables transformer Max. additional power rating of Halogen units...
  • Page 5: Mounting The Lamps

    4.2 Mounting the Lamps Open the light fittings by pulling the cover pieces to the left and right of the CCFL tubes up. Loosen the screws on the basic units end caps on the base of the lamp housing and remove them sideways. Now the mounting holes in the base and the plug are accessible.
  • Page 6: Connection

    5. Connection The controller circuit board with all the connectors found under the short cover plate of one of the lamp housings. The CCFL tubes are supplied with up to 800V alternating current. Only open the equipment with the power switched off! 5.1 The Connecting Sockets 1 LocoNet connector for the digital control (base unit only)
  • Page 7: Connecting Lightning & Sound

    Additional unit must be provided with further transformers in groups. this, the first unit in each group will not receive its power from the previous unit but instead from the additional transformer. The two data lines on the other hand must not be separated from the previous unit. AC power from transformer or output to the next unit Data line Data line earth...
  • Page 8: Connecting An External Amplifier

    the side panel of the lamp box. power cable must be run to the loudspeaker between metal chassis and base of the lamp. 5.5 Connecting an external Amplifier Near the loudspeaker of the sound unit is a board with a connector. An external amplifier can be connected to this.
  • Page 9: Operation Via Solenoid Addresses (Digital)

    6.1 Operation via Solenoid addresses (digital) If the light system is operated from a digital center with LocoNet connection (Intellibox, DAISY, Märklin 6021 with 6021-Infrarot & LocoNet adapter, Fleischmann TwinCenter, Piko power box), the individual events are switched using the following solenoid addresses: Solenoid address Setting Event Sunset...
  • Page 10: Synchronization With A Loconet Clock

    • Enter the part number of the module (here 63410) and press the [ ]-key. • Enter the part number of the IntelliLight module (here 28000) and press the [ ]-key. • Enter the module address (in a new module this is 1) and press the [ ]- key.
  • Page 11: Reading And Programming Of An Intellilight Module

    Press the [mode]- key • Using the [ ]-key scroll down to the “LocoNet Prog.“ menu • Press the [ ]-key • Enter the part number (the IntelliLight base unit is 28000) • Enter the universal address 65535 • Press [ ]-key •...
  • Page 12: Lncv Table

    Mon - Tue - Thu - Fri., 14:00-16:00 and Wednesdays 16:00-18:00 This product has a two year warrantee. If it is defective send decoder along with the receipt of purchase to the following address: Uhlenbrock Elektronik GmbH * Mercatorstr. 6 * 46244 Bottrop Tel: 02045-85830 * Fax: 02045-86840 * www.uhlenbrock.de...