Altronix ABH-B Series Installation Manual

Digital 8-frequency conversion active infrared detector

Advertisement

Quick Links

Digital 8-frequency conversion
active infrared detector
Installation guide
III. Installation notice
Impediment presents during setup
The base is unstable
Direct sunlight,lamplight etc.
Guarding distance
R e c e i v e r R e c e i v e r R e c e i v e r R e c e i v e r
ABH-B series
88
Multi sensors may be used for long-distance
guarding. Please install according to the below
diagram to avoid interference between beams.
Adjustable angle: horizontal ±90
vertical ±10
Horizontal 180 ( 90 )
vertical ±10 °
Model
Guarding distance
Beam spread diameter
I. Specification
Model
Outdoor
Alert distance
Indoor
No. of beams
Detection mode
Optical source
Response speed
Alarm output
Power supply
Power consumption
Operation temperature & humidity
Tamper output
Optical axis adjustment(H)
Optical axis adjustment(V)
Material
Net weight
Gross
II. Parts
Features:
1. Under BUS connection mode: The digital display of RX synchronize with the TX after the RX receive the signal from BUS
2. Anti-fog function: When signal strength decrease slowly to 0.8V,the detector will active anti-fog alarm( TBL output), when
signal decrease to 0.4V, will active alarm, when signal get back to 1.2V cancel alarm.
IV.Installation method
1.Remove the cover
4.Fix the main body onto the wall
88
°
°
6. DIP setting
Transmitter
Frequency set mode
FRE.
Table 1
Function setting(table 2)
1. Under frequency mode: The digital display shows the frequency, Set frequency on DIP1.2.3(see table 1)
2. Under address mode: The digital display shows BUS address, set the address on DIP1.2.3.4.5.6
3.Under signal strength mode: The digital display shows the signal strength, the DIP1.2.3.4.5.6 under this mode is invalid
4.Under address/frequency alternately display mode: The digital display shows address and frequency alternately,
the DIP1.2.3.4.5.6 under this mode is invalid
Frequency setting:(First enter frequency setting mode, see table 2)
Then set DIP 1.2.3 to set detector's frequency( see table 1)
BUS address setting:(First enter address mode, see table 2)
Under address mode, Set DIP 1-6 to set the detector's zone address. first set DIP at ON,
the number of the one DIP which set ON puls the other one, then plus 1,
the final result of number is the zone number, example this is zone 18(17+1)
4 beams
4 beams blocked simultaneous
Infrared digital pulse beam
50 240msec adjustable
Relay contact output: NO. NC contact rating: AC/DC30V 0.5AMax
-25 -55 5%-95%RH(relative humidity)
Contact output: NC contact rating DC24V 0.3Amax
PC resin
2000g(receiver +transmitter)
Wiring hole
Wiring terminal
Lens
Horizontal fine-tune knob
Housing
2.Attach the paper stencil onto the location
where the equipment is to be mounted, and
drill the holes in the positions on its mark.
5.Connect the cable to the wire terminal.
88
Receiver
BUS address setting
Air terminal
Air terminal
Function set mode
Frequency set mode
Mode
Signal strength
Frequency mode
88
Vertical fine-tune knob
3.Put the cable through the hole for wiring.
Wiring hole
Receiver
BUS
Transmitter
BUS
BUS address setting
Alarm output N.O/N.C setting
Buzzer ON/OFF setting
Function set mode
Address/frequency alternately
Address mode
display mode
Table 2

Advertisement

loading
Need help?

Need help?

Do you have a question about the ABH-B Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Altronix ABH-B Series

  • Page 1 50 240msec adjustable Alarm output Installation guide Relay contact output: NO. NC contact rating: AC/DC30V 0.5AMax Power supply Power consumption ABH-B series Operation temperature & humidity -25 -55 5%-95%RH(relative humidity) Tamper output Contact output: NC contact rating DC24V 0.3Amax Optical axis adjustment(H)
  • Page 2 VII.Response time adjustment 7. BUS wiring: Transmitter Transmitter Receiver Transmitter Please see the diagram to adjust the response Receiver Receiver time of receiver,Usually, the time set shall be less than the time when the intruder crosses the guarding area 50ms 240ms Set 0 Set 1...

This manual is also suitable for:

Abh-50Abh-100Abh-150Abh-200Abh-250