MAX LIGHT MEASUREMENT REPORT Page: 2/68 Technology Lab Table of Contents : I. Description of EUT II. Evaluation III. Conducted/Radiated Emissions Requirements (EMI) IV. Harmonics/Voltage Fluctuation and Flicker Test V. Electrostatic Discharge Requirements VI. Radiated Electromagnetic Field Requirements VII. Electrical Fast Transient/Burst Requirements VIII.
Page 3
Manufacturer : UNICLASS TECHNOLOGY CO., LTD. 4F, No. 98, Ming Chuan Rd., Hsintien, Taipei, Taiwan Model No : USB-SP02A/USB-SP02 1.2 Technical data of EUT Input Rating : Powered By PC(Via +5Vdc) 1.3 Configuration of EUT This 2 Port Slim Palmtop USB KVM Switchconsists of...
Page 4
* EN 55024: 1998+A1: 2001+A2: 2003 Information technology equipment- Immunity characteristics- Limits and methods of measurement Max Light Technology Co., Ltd. Test Center: Remark : The test results only relate to the submitted test sample specified above. Report Number: MLT0512EMC002...
Page 5
MAX LIGHT MEASUREMENT REPORT Page: 5/68 Technology Lab III. Conducted/Radiated Emissions Requirements (EMI) 3.1 General: The conducted emissions test from 150KHz to 30MHz is employed to the power line through a LISN (Line Impedance Stabilization Network). The limits are 66-56dBuV(QP) / 56-46dBuV(Average), decreases linearly with the logarithm for 0.15-0.50MHz;...
Page 6
MAX LIGHT MEASUREMENT REPORT Page: 6/68 Technology Lab 3.4 Test Equipment List: A. EMCO 3825/2 LISN (S/N:2654) B. EMCO 3825/2 LISN (S/N:2658) C. Schaffner T411 ISN (S/N:A432) D. HP 8591EM 9KHZ-1.8GHz Spectrum Analyzer (S/N:73412A00110) E. Shielded Room (MLT-SR1) F. HP 8591EM 9KHz-1.8GHz Spectrum Analyzer (S/N:73412A00230) G.
Page 7
MAX LIGHT MEASUREMENT REPORT Page: 7/68 Technology Lab 3.8 Conducted Emissions Limits (Telecommunication Port): Current Limits (dBuV) Frequency range (MHz) Quasi-peak Average 0.15 to 0.50 40 to 30 30 to 20 0.50 to 30 3.9 Radiated Emissions Limits: Quasi-peak (dBuV/m)
Page 8
MAX LIGHT MEASUREMENT REPORT Page: 8/68 Technology Lab 3.10 Measurement Data Of Conducted Emissions: 3.10.1 Conducted Emissions (Mains Power) The following table show a summary of the highest emissions of power line conducted emissions to the HOT and NEUTRAL conductor of the EUT power.
Page 9
HOT and NEUTRAL conductor of the EUT power. Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 12/21/2005...
Page 10
MAX LIGHT MEASUREMENT REPORT Page: 10/68 Technology Lab 3.11 Measurement Data Of Radiated Emissions: 3.11.1 Open Field Radiated Emissions (HORIZONTAL) The highest peak values of radiated emissions from the EUT at various antenna heights, antenna polarization, EUT orientation , etc. are recorded on the following.
Page 11
MAX LIGHT MEASUREMENT REPORT Page: 11/68 Technology Lab 3.11.2 Open Field Radiated Emissions (VERTICAL) The highest peak values of radiated emissions from the EUT at various antenna heights, antenna polarization, EUT orientation , etc. are recorded on the following. Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Page 12
EUT orientation , etc. are recorded on the following. Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 12/14/2006...
Page 13
EUT orientation , etc. are recorded on the following. Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 12/14/2006...
Page 14
MAX LIGHT MEASUREMENT REPORT Page: 14/68 Technology Lab IV. Harmonics/Voltage Fluctuation and Flicker Test 4.1 General: This standard is applicable to electrical and electronic equipment for household and similar use, intended to be connected to low-voltage A.C distribution system of the following types: nominal voltages up to 240V, single-phase, two or tree wire;...
Page 15
MAX LIGHT MEASUREMENT REPORT Page: 15/68 Technology Lab User’s operation controls or automatic programmer shall be set to produce the maximum harmonic components, for each successive harmonic component in turn. A definition of the normal load or of the conditions for adequate heat discharge can usually be found in the EN publication corresponding to the equipment under test.
Page 17
Pst: (0), Plt: (0), Dc: (0), Dmax (0)m Dt (0) Total Number Of Errors None 4.8 Measurement Data Of Harmonic: Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 12/16/2005 Classification...
Page 19
MEASUREMENT REPORT Page: 19/68 Technology Lab 4.9 Measurement Result Of Flicker: Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 12/16/2005 Classification : Class A Input Voltage : 230.3V...
MAX LIGHT MEASUREMENT REPORT Page: 20/68 Technology Lab Electrostatic Discharge Requirements (ESD) 5.1 General: This requirement relates to the EUT may be involved static electricity discharges owing to environmental and installation conditions. A transfer of electrostatic charge between objects of different electrostatic potential may cause harmful to the EUT.
Page 21
MAX LIGHT MEASUREMENT REPORT Page: 21/68 Technology Lab 2.Air discharge at slots and apertures, and insulating surfaces: The equipment should be investigated to identify user accessible points where breakdown may occur. Such points are tested using the air discharge method. The investigation should be restricted to those areas normally handled by the user.
Page 22
MAX LIGHT MEASUREMENT REPORT Page: 22/68 Technology Lab 5.7 Test Result: Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02/USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 01/11/2006 Voltage Coupling...
MAX LIGHT MEASUREMENT REPORT Page: 29/68 Technology Lab VI. Radiated Electromagnetic Field Requirements (RS) 6.1 General: Most electronic product is in some manner affected by environmental electromagnetic radiation, the performance will be degraded or totally un-function. The object of this part is to evaluate the susceptibility of the...
Page 30
MAX LIGHT MEASUREMENT REPORT Page: 30/68 Technology Lab The rate of sweep is in the order of 1.5x10 -3 decades/s with the EUT in its most sensitive orientation. Where frequency range swept incrementally, the step size is 1% of fundamental with linear interpolation between calibrated points.
Page 31
MAX LIGHT MEASUREMENT REPORT Page: 31/68 Technology Lab 6.7 Test Result: Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02/USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 01/11/2006 Range Field...
MAX LIGHT MEASUREMENT REPORT Page: 32/68 Technology Lab VII. Electrical Fast Transient/Burst Requirements (EFT) 7.1 General: The test is intended to show the immunity of the EUT when subjected to types of transient interference such as originating from switching transients. Bursts consisting of a number of fast transients are employed, coupled into power supply, control and signal inputs of EUT.
Page 33
MAX LIGHT MEASUREMENT REPORT Page: 33/68 Technology Lab Bursts of 5ns/50ns pulses at a repetition rate of 5kHz with a duration of 15ms and period of 300ms, applied in both polarities between power supply terminals (including the protective earth) and a reference ground plane, or via a capacitate coupling clamp onto I/O circuits and communication lines for 3 minutes.
Page 34
MAX LIGHT MEASUREMENT REPORT Page: 34/68 Technology Lab 7.7 Test Result: Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02/USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 01/11/2006 Connected Voltage...
MAX LIGHT MEASUREMENT REPORT Page: 35/68 Technology Lab VIII. Surge Requirements 8.1 General: The object of this section to establish a common reference for evaluating the performance of equipment when subjected to high-energy disturbances on the power and interconnection lines. The test is to find the reaction of the EUT under specified operational conditions caused by surge voltages from switching and lightning effects at certain threat levels.
Page 36
MAX LIGHT MEASUREMENT REPORT Page: 36/68 Technology Lab 8.3.2 Unshielded unsymmetrically operated interconnection lines The coupling / decoupling network shall not influence the specified functional conditions of the circuits to be tested. Selection shall be made depending on the capacitive load with respect to transmission frequency.
Page 37
: 15-35 Degrees Celsius Relative Humidity : 10-75 % 8.7 Test Result: Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02/USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 01/11/2006 Connected...
MAX LIGHT MEASUREMENT REPORT Page: 38/68 Technology Lab IX. Immunity to Conducted Disturbances, Induced by Frequency Field Requirements 9.1 General: The Source of disturbance covered by this section of IEC 61000-4-6 is basically an electromagnetic field, coming from intended RF transmitters, that may act on the whole length of cables connected to an installed equipment.
Page 39
MAX LIGHT MEASUREMENT REPORT Page: 39/68 Technology Lab 9.3 Setup: Local interference regulations shall be adhered to with respect to the radiation from the test set-up. If the radiated energy exceeds the permitted level, a shielded enclosure shall be used.
Page 40
Step : 1% Step time : 3 Second 9.7 Test Result: Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02/USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 01/11/2006 Range Field...
MAX LIGHT MEASUREMENT REPORT Page: 41/68 Technology Lab X. Voltage Dips, Short Interruptions and Voltage Variations Requirements 10.1 General: The Section of IEC 61000-4-11 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips.
Page 42
MAX LIGHT MEASUREMENT REPORT Page: 42/68 Technology Lab 10.3 Setup: The test shall be performed with the EUT connected to the test generator with the shortest power supply cable as specified by EUT manufacturer. If no cable length is specified, it shall be the shortest possible length suitable to the application of the EUT.
Page 43
: 15-35 Degrees Celsius Relative Humidity : 25-75 % 10.7 Test Result: Applicant : UNICLASS TECHNOLOGY CO.,LTD. Model No : USB-SP02/USB-SP02A : 2 Port Slim Palmtop USB KVM Switch Test Mode : Send H pattern Test Date : 01/11/2006 Level...
MAX LIGHT MEASUREMENT REPORT Page: 44/68 Technology Lab Appendix I- EUT Test SETUP MEASUREMENT OF POWER LINE CONDUCTED RFI VOLTAGE 0.8M 0.8M LISN Metal floor surfaced with 30mm of insulating material Report Number: MLT0512EMC002 Issue Date:01/13/2006...
Page 45
MAX LIGHT MEASUREMENT REPORT Page: 45/68 Technology Lab Appendix I- EUT Test SETUP MEASUREMENT OF RADIATED EMISSION Antenna Tower 4.0M Receiver Antenna 0.8M Ground Plane 0000 RF Test Receiver Report Number: MLT0512EMC002 Issue Date:01/13/2006...
Page 46
MAX LIGHT MEASUREMENT REPORT Page: 46/68 Technology Lab Appendix I- EUT Test SETUP MEASUREMENT OF POWER HARMONICS >0.5M Harmonics Measuring Equipment Equipment Under Test Non-Metallic Table Non-Metallic Table Non-Metallic Table (1)Connected to mains supply system. (2)Power Supply Line of EUT.
Page 47
MAX LIGHT MEASUREMENT REPORT Page: 47/68 Technology Lab Appendix I- EUT Test SETUP MEASUREMENT OF ELECTRO STATIC DISCHARE >10M 0.1M Vertical Coupling Nearest Plane Generator Wall Isolation Horizontal Coupling Aluminum Plane Plane Reference Ground Plane (1)Connected to auxiliary power supply unit of ESD generator.
Page 48
MAX LIGHT MEASUREMENT REPORT Page: 48/68 Technology Lab Appendix I- EUT Test SETUP MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELD Enclosure Chamber RF OUT Meltering Unit 7122 IFI5540 Amplifier Monitor 0.8M SMGL Field Generator Probe GPIB EMCO 7110 FIBER RG-59 Controller Report Number: MLT0512EMC002...
Page 49
MAX LIGHT MEASUREMENT REPORT Page: 49/68 Technology Lab Appendix I- EUT Test SETUP MEASUREMENT OF FAST TRANSIENTS/BURST >0.5M Nearest Wall EFT/B Generator Coupling/Decoupling Network Non-Metallic Table Aluminum Plane Reference Ground Plane (1)Connected to AC mains supply. (2)EFT/BURST and AC power supply to EUT.
Page 51
MAX LIGHT MEASUREMENT REPORT Page: 51/68 Technology Lab Appendix I- EUT Test SETUP Immunity to Conducted Disturbances, Induced by Frequency Field AC Power System Power Cable Ground Reference Plane 0.1m Support RF-Generator Power Amp Report Number: MLT0512EMC002 Issue Date:01/13/2006...
Page 52
MAX LIGHT MEASUREMENT REPORT Page: 52/68 Technology Lab Appendix I- EUT Test SETUP Voltage Dips, Short Interruptions and Voltage Variations Voltage Dip/Interruption Generator Coupling/Decoupling Network Non-Metallic Table Aluminum Plane Reference Ground Plane Report Number: MLT0512EMC002 Issue Date:01/13/2006...
Page 53
MAX LIGHT MEASUREMENT REPORT Page: 53/68 Technology Lab Appendix II- Users Manual See Next Page Report Number: MLT0512EMC002 Issue Date:01/13/2006...
Page 54
2/4-port Slim Palmtop USB KVM Switch w/ optional Audio&Mic Quick Installation Guide Thank you for purchasing the USB-SP02/USB-SP02A/USB- SP04A Slim Palmtop USB KVM Switch w/ Audio&Mic! With our highly reliable and quality product, user can enjoy countless benefits from using it.
Page 55
Operation Quick Reference Applicable models: USB-SP02 / USB-SP02A / USB-Sp04A Slim Palmtop USB KVM Switch - Operation Quick Reference There are three methods to control your KVM Switch Right-click the KVM Switcher icon to evoke the operation All the hotkeys are only functional after your PCs are booting into the OS.
Page 56
MAX LIGHT MEASUREMENT REPORT Page: 54/68 Technology Lab Appendix III- Schematic Diagram See Next Page Report Number: MLT0512EMC002 Issue Date:01/13/2006...
Need help?
Do you have a question about the USB-SP02A and is the answer not in the manual?
Questions and answers