General .......................... 24 Maintenance ........................24 Repairs .......................... 24 Spare parts ..................24 Spare Parts List and Drawing ............121 11.1 Spare Parts List ......................121 C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
• Regardless of what nature they may be, repairs must only be carried out by qualified persons and the counter-current unit must be emptied first. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
67 + 2 dB (A) 70 + 2 dB (A) Weight 16 kg 17 kg 20 kg 21 kg 25 kg *WS = AC (alternating current) Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
The model supplied to you can be found in the spare parts list for your pool type. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
Page 6
2. Clamp ring Item 72 3. Clamp gasket Item 32 4. Mounting screws Item 74 Note: Parts 2 to 4 are delivered with the face plate assembly. Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
There are two base frames available that must be ordered separately to suit local circumstances. 1. W = for wall mounting 2. B = for floor mounting 8215 fig. 8: C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
7. The position of the switchgear cabinet (S) must always be over the pool water level (BWSP). 8. In case of leakage from the pump, a suitable water drainage must be provided! Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H...
The installation kit must be horizontal. • The distance between the centre of the installation kit and the water level (BWSP) must be 275 mm. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
Warning! Risk of damage! The hold-ring (68) must be used as a template. Take note of the asymmetrical position of the holes! 88221 fig. 14: Boring diagram Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
(22) with the screws (74). Warning! The housing (91) must be mounted so that the connection for the membrane switch (MS) is at the top. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
“N” in fig. 18. Warning! The installation kit (92) must be mounted so that the connection for the membrane switch is at the top. Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
Warning! Always be sure to lay the pipework using 8227 bends and not angles to keep the pipe fig. 20 resistance to a minimum. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
(compensator function), see diagram. 4.12 Installing the switchgear cabinet For electrical connection information regarding the Control NT panel, please refer to the corresponding instruction manual 27248 fig. 22 Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
(21) with the hose coupling (A) onto the plug sleeve (B) on the face plate assembly (D). With that the air button is connected to the switchgear cabinet. 8231 fig. 24 C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
Page 16
(72) with the screws (90.2). Warning! Make sure that there is not a kink in the switching tube (21), lay it in a loop and do not shorten! Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
The electrical connections to the counter-current swimming system must be carried out by a specialised company in the electrical engineering branch approved by the local energy provider, taking into account the technical connection requirements. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
(230 V for 1~) Switchgear cabinet = Capacitor Connection cable, example, HO7RNF, all further details required for 8236 fig. 29 making connections can be found in chapter 3.1. Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
31: Basic circuit diagram for 400/ HO7RNF, all further details required for 230 V three-phase current making connections can be found in chapter 3.1. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
The pump is switched on by pressing the switching button (Z). After 2 seconds the pump can be switched off by pressing the button again or a signal can be sent to the pump (on- off function). Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H...
Page 21
Press the hose coupling (F) against the sliding sleeve (V), take a hold of it and pull it back, pull out the hose coupling. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
Screw the air valve off and wash it out during normal operation. Replace it, if necessary. Note: The air valve must be located above the water surface. Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
Then screw the plug screw (11) back in again with a new O-ring (07). When restarting please observe the 8244 instructions in section 6. fig. 34 C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
In the following spare parts list there are all the parts required for your counter-current unit. When ordering spare parts please specify the pump number and the order number of the individual part(s) in this list. Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H...
Need help?
Do you have a question about the fluvo C2G rondo and is the answer not in the manual?
Questions and answers