Advertisement

Quick Links

C2G rondo
D
Operating Instructions
GB
Transplantation of the original

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the fluvo C2G rondo and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmalenberger fluvo C2G rondo

  • Page 1 C2G rondo Operating Instructions Transplantation of the original...
  • Page 2: Table Of Contents

    General .......................... 24 Maintenance ........................24 Repairs .......................... 24 Spare parts ..................24 Spare Parts List and Drawing ............121 11.1 Spare Parts List ......................121 C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 3: General

    • Regardless of what nature they may be, repairs must only be carried out by qualified persons and the counter-current unit must be emptied first. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 4: Symbols

    67 + 2 dB (A) 70 + 2 dB (A) Weight 16 kg 17 kg 20 kg 21 kg 25 kg *WS = AC (alternating current) Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 5: Device Units

    The model supplied to you can be found in the spare parts list for your pool type. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 6 2. Clamp ring Item 72 3. Clamp gasket Item 32 4. Mounting screws Item 74 Note: Parts 2 to 4 are delivered with the face plate assembly. Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 7: Installation Site Specifications / Installation

    There are two base frames available that must be ordered separately to suit local circumstances. 1. W = for wall mounting 2. B = for floor mounting 8215 fig. 8: C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 8: Planning The Pump Pit

    7. The position of the switchgear cabinet (S) must always be over the pool water level (BWSP). 8. In case of leakage from the pump, a suitable water drainage must be provided! Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H...
  • Page 9: Installation Preparations / Concrete Pool

    The installation kit must be horizontal. • The distance between the centre of the installation kit and the water level (BWSP) must be 275 mm. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 10: Installation Preparations / Pre-Fabricated Pool

    Warning! Risk of damage! The hold-ring (68) must be used as a template. Take note of the asymmetrical position of the holes! 88221 fig. 14: Boring diagram Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 11: Installation - General

    (22) with the screws (74). Warning! The housing (91) must be mounted so that the connection for the membrane switch (MS) is at the top. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 12: Mounting The Installation Kit / Wooden-Liner Pool

    “N” in fig. 18. Warning! The installation kit (92) must be mounted so that the connection for the membrane switch is at the top. Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 13: Pump Kit Installation

    Warning! Always be sure to lay the pipework using 8227 bends and not angles to keep the pipe fig. 20 resistance to a minimum. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 14: Connection To The Pump

    (compensator function), see diagram. 4.12 Installing the switchgear cabinet For electrical connection information regarding the Control NT panel, please refer to the corresponding instruction manual 27248 fig. 22 Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 15: Non-Return Air Valve Installation

    (21) with the hose coupling (A) onto the plug sleeve (B) on the face plate assembly (D). With that the air button is connected to the switchgear cabinet. 8231 fig. 24 C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 16 (72) with the screws (90.2). Warning! Make sure that there is not a kink in the switching tube (21), lay it in a loop and do not shorten! Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 17: Electrical Connections

    The electrical connections to the counter-current swimming system must be carried out by a specialised company in the electrical engineering branch approved by the local energy provider, taking into account the technical connection requirements. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 18: Electrical Connections Ac

    (230 V for 1~) Switchgear cabinet = Capacitor Connection cable, example, HO7RNF, all further details required for 8236 fig. 29 making connections can be found in chapter 3.1. Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 19: Electrical Connections Three-Phase Current

    31: Basic circuit diagram for 400/ HO7RNF, all further details required for 230 V three-phase current making connections can be found in chapter 3.1. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 20: Start-Up / Operating

    The pump is switched on by pressing the switching button (Z). After 2 seconds the pump can be switched off by pressing the button again or a signal can be sent to the pump (on- off function). Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H...
  • Page 21 Press the hose coupling (F) against the sliding sleeve (V), take a hold of it and pull it back, pull out the hose coupling. C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 22: Fault Assistance

    Screw the air valve off and wash it out during normal operation. Replace it, if necessary. Note: The air valve must be located above the water surface. Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 23: Shutdown / Overwintering

    Then screw the plug screw (11) back in again with a new O-ring (07). When restarting please observe the 8244 instructions in section 6. fig. 34 C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 24: Maintenance And Repair

    In the following spare parts list there are all the parts required for your counter-current unit. When ordering spare parts please specify the pump number and the order number of the individual part(s) in this list. Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H...
  • Page 25: Spare Parts List And Drawing

    Aire pipe clamp S86/25 SKZ 16095 Schlauch Hose Ø 60 x 300mm 55793 Schlauchverbindungs- Adaptor stutzen 16099 Schlauch Tuyau flexible Hose Ø 75 x 300mm C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 26 Sechskantschraube Hexagon screw M8 x 30 55272 Befestigungsschelle Clamp 67005 Spreizdübel Rawl plug SD 8 60045 Luftventil Non-return air valve 10244 Blechschraube Tapping screw 4,2x13 Schmalenberger GmbH + Co. KG C2G rondo Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 27 M8x45 93129 Einbausatz Installation kit 93128 Einbausatz Installation kit 10530 Sechskantschraube Hexagon screw M8x50 55539 Abstandshülse Distance washer 24424 V-Ring V-ring 22213 Flachdichtung Clamp Gasket C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 28 Drawing 8245 C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 29 Drawing 8246 C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 30 Drawing 8247 C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 31 Drawing 8248 C2G rondo Schmalenberger GmbH + Co. KG Version: 27201 - H D-72072 Tübingen / Germany...
  • Page 32 +49 (0)7071 70 08 - 10 Im Schelmen 9 - 11 Internet: www.fluvo.de D-72072 Tübingen / Germany E-Mail: info@schmalenberger.de © 2020 Schmalenberger GmbH & Co. KG ; All rights reserved This document is subject to change without notice Typ: C2 rondo Version: 27201 - H...

Table of Contents