  • Page 1 User Manual for the GP1/DL6 GSM Modem System GSM-UM-1.1 Delta-T Devices...
  • Page 2 Product Documentation folder of the Delta-T Software and Manuals CD. Design Changes Delta-T Devices Ltd reserves the right to change the designs and specifications of its products at any time without prior notice. User Manual Version: GSM-UM-1.1 Dec 4 2006...
  • Page 3: Table Of Contents

    Specifications ................. 24 Environmental specifications ................... 26 Electromagnetic Compatibility (EMC) ..............26 Care and Safety............... 27 Technical Support ..............27 Terms and Conditions of sale .................. 27 Service and Spares ....................28 Technical Support....................28 © 2006 Delta-T Devices Ltd Page 3...
  • Page 4: Layout

    Solar panel bracket Solar regulator /charger Modem Antenna connector Modem power cable RS232 to logger + control line for text messaging Battery Cable Timer Fuse and Brown +’ve harness connectors on DIN rail © 2006 Delta-T Devices Ltd Page 4...
  • Page 5: External Connectors And Cable Glands

    Cable glands for 1) external antenna, 2) external battery or solar panel Breather and/or 3) control line from logger for triggering M8 socket text messages for connecting to logger(s) via GP1 Network Cabling © 2006 Delta-T Devices Ltd Page 5...
  • Page 6: Introduction

    The GSM modem can be configured to send a text message to a mobile phone, when triggered by a logger control relay. It requires a 2-core cable from the logger to the modem box DIN rail terminals. © 2006 Delta-T Devices Ltd Page 6...
  • Page 7: Unpacking

    10Ah sealed lead acid battery. Timer GSM Modem Box (without battery) type GSM-BX1/EB In addition to the Basic Box and Modem, this includes: Timer This does not include a battery or external battery cable. © 2006 Delta-T Devices Ltd Page 7...
  • Page 8: Accessories

    GP1-EXT-XX XX = 1m, 5m, 10m, or 25m GP1 control line cable GP1-CC-100 GSM external battery cable GP1-EPC-02 DL6 M12 cable to M8 GP1/DL6-M8 connector 4-way GP1 network GP1-EB/4 expansion block © 2006 Delta-T Devices Ltd Page 8...
  • Page 9: Also Required For All Systems

    See also the Accessories on page 8. To obtain the latest DeltaLINK version Link to http://delta-t.co.uk/software-download.html. To Upgrade DeltaLINK-PC firmware To upgrade your firmware, from the PC Start menu select Programs, DeltaLINK-PC, Firmware Upgrade, and follow the on-screen instructions. © 2006 Delta-T Devices Ltd Page 9...
  • Page 10: Getting Started

    M3 x 35mm screws Find the SIM card slot and press the adjacent button to eject the card holder. Fit the data enabled SIM card Refit the modem in the box. Locate SIM card eject button © 2006 Delta-T Devices Ltd Page 10...
  • Page 11: Install The Antenna

    Push it over the cable, and reassemble as shown. Screw the FME connector into the modem. For optimum reception mount the antenna vertically and high up. 275 mm 155mm 31 mm 45 mm 29 mm © 2006 Delta-T Devices Ltd Page 11...
  • Page 12: Supply Power To The Modem

    The power distribution at the DIN rail is also configured to provide continuous external power for GP1 loggers. You may disable this if you like. See: How to disconnect the external power supply to GP1 loggers on page 19 © 2006 Delta-T Devices Ltd Page 12...
  • Page 13: Configure, Test Or Add Text Message To Modem

    GSM Modem will be used with to DL6/GP1. Set GSM modem is connected to the PC serial p ort that you are using. Click Configure modem now. Click Help for additional on-scre en instructions. © 2006 Delta-T Devices Ltd Page 13...
  • Page 14 GSMConfig as described above.) Enable text messaging Complete stage 1-4 on page 13 then Click Enable SMS text message transmission, and enter text messaging settings. Click Configure GSM modem now. Click Help for additional on-screen instructions. © 2006 Delta-T Devices Ltd Page 14...
  • Page 15 Connect the logger to your PC, start DeltaLINK and select the Sensors window Connect up and place sensors in conditions which should cause a text message transmission. You should hear the relay click and receive a text message shortly after. © 2006 Delta-T Devices Ltd Page 15...
  • Page 16: Create A Modem Connection In Deltalink

    Modem System, and click OK . DeltaLINK will now dial and connect to your logger. You can later select the connection that you have just created to connect to the same logger again. © 2006 Delta-T Devices Ltd Page 16...
  • Page 17: Install Modem Box

    If using the internal antenna, careful placement of the box may assist signal reception. Mounting Kit for GSM Modem Box type GSM-MK1. Use this, with the U-bolts provided, for attaching to a post or mast. © 2006 Delta-T Devices Ltd Page 17...
  • Page 18: Install Solar Panel (Option)

    (Brown=positive, blue=negative) See also: Solar Charge Controllers Instructions for the Solsum 6.6c © 2006 Delta-T Devices Ltd Page 18...
  • Page 19: Install Logger(S)

    GSM Modem Box battery can be disconnected at the DIN rail. Disconnect the cable labelled External Power. It has “black” and “white” wires and is clearly indicated in the Wiring schemes on pages 21 to 22. © 2006 Delta-T Devices Ltd Page 19...
  • Page 20: Battery Life Considerations

    DL6 loggers cannot take external power and so have no impact. External power to the GP1 loggers via the extension cabling may be disabled at the DIN rail in the Modem Box, leaving the loggers to rely on their internal batteries © 2006 Delta-T Devices Ltd Page 20...
  • Page 21: Wiring Diagrams

    7.5A Fuse Modem Modem power External power Text message control 3A Fuse Battery Wiring scheme for Solar Power and Timer 7.5A Fuse Modem Modem power External power 3A Fuse Text message control Timer Battery © 2006 Delta-T Devices Ltd Page 21...
  • Page 22: Wiring Scheme For Gsm-Bx1Eb

    Modem Modem Modem power External power Text message control Timer GP1-EPC-02 Battery External battery cable Wiring scheme for GSM-BX1/ IB…Internal Battery Modem Modem power 3A Fuse External power Text message control Timer Battery © 2006 Delta-T Devices Ltd Page 22...
  • Page 23: Other Documents

    SX20-40 Single Module Mounting Kit Instructions SM-421A Issued with solar panel bracket. Instruction Sheet and a separate Appendix issued with Solar Panel Wiring diagram on back of Solar Panel. DIN Rail Timer Instruction Manual supplied with digital Timer. © 2006 Delta-T Devices Ltd Page 23...
  • Page 24: Specifications

    - for Siemens TC35i modem, FME connector. For use in areas where mobile phones work OK. If reception is poor try using external antenna with ground plane mounted high up and clear of obstructions © 2006 Delta-T Devices Ltd Page 24...
  • Page 25 3 off 3A fuses for DIN rail. 3 off 7.5A fuses for charger/regulator. GSM Modem 2x 25 gm activated clay desiccant bags, 50cm spiral wrap, 5 cable ties. Spare DIN rail cable, 3 blanking plugs for cable glands. GSM-SK1 © 2006 Delta-T Devices Ltd Page 25...
  • Page 26: Environmental Specifications

    This product meets the intent of the EMC Directive 89/336/EEC. For a certificate of conformity see: GSM-BX1 & GP1-DL6 Network Regulatory Information.pdf in the Product Documentation folder of the Delta-T Software and Manuals CD . © 2006 Delta-T Devices Ltd Page 26...
  • Page 27: Care And Safety

    Delta-T's premises in the UK, during the warranty period. If Delta-T requires that goods under warranty be returned to them from overseas for repair, Delta-T shall not be liable for the cost of carriage or for customs clearance in © 2006 Delta-T Devices Ltd Page 27...
  • Page 28: Service And Spares

    Contact Details Tech Support Team Tel: +44 (0) 1638 742922 Delta-T Devices Ltd Fax: +44 (0) 1638 743155 130 Low Road, Burwell, email: tech.support@delta-t.co.uk Cambridge CB25 0EJ, U.K. web: www.delta-t.co.uk © 2006 Delta-T Devices Ltd Page 28...