Over-temperature controller

Advertisement

Installation, Operation and Maintenance Instructions
Controller Manual

132 Over-Temperature Controller

MEN-132OT_CTRL (18-02-2022)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 132 and is the answer not in the manual?

Questions and answers

Summary of Contents for Carbolite Gero 132

  • Page 1 Installation, Operation and Maintenance Instructions Controller Manual 132 Over-Temperature Controller 132 Over-Temperature Controller MEN-132OT_CTRL (18-02-2022)
  • Page 2 Contents This manual is for guidance on the use of the Carbolite Gero product specified on the front cover. This manual should be read thoroughly before unpacking and using the furnace or oven. The model details and serial number are shown on the back of this manual.
  • Page 3 1.1.1 Controls Most Carbolite Gero products are fitted with an instrument switch which cuts off power to the controller and other parts of the control circuit. To operate the controller, power must be supplied to the product and the instrument switch must be on.
  • Page 4 1.2 Operation To change the over-temperature alarm setpoint: 1. Use the up and down buttons to adjust the setpoint to the desired temperature. 2. Press the Menu/OK button to accept the new value. OK will appear briefly on the lower half of the display. The example pictured shows an over-temperature alarm setpoint being adjusted from 300°C to 500°C.
  • Page 5 1.3 Over-Temperature Alarm If the over-temperature alarm state is triggered: The product will stop heating and OVERTEMP will be displayed on the scrolling text on the lower half of the display. To acknowledge / reset the alarm: Press and hold the return button. Note: The over-temperature alarm cannot be acknowledged / reset until the actual temperature drops below the over-temperature setpoint.
  • Page 6 1.5 Audible Alarm If an audible alarm is supplied for use with the over-temperature controller, it is normally configured to sound when the over-temperature alarm is triggered, and to stop sounding when the alarm is acknowledged. Note: The alarm may sound during controller start-up.
  • Page 7 Notes Service Record Engineer Name Date Record of Work...
  • Page 8 The products covered in this manual are only a small part of the wide range of ovens, chamber furnaces and tube furnaces manufactured by Carbolite Gero for laboratory and industrial use. For further details of our standard or custom built products please contact us at the address below, or ask your nearest stockist.