CARBON MONOXIDE ALARM USER MANUAL
ELECTROCHEMICAL CARBON MONOXIDE ALARM GS811-A

PRODUCT SPECIFICATIONS:

Power:
DC 4.5V(AA 1.5V*3) ba�ery operated
Opera�on Current:
< 40uA(standby), < 10mA (alarm)
Sensor Type:
Electrochemical
Alarm Volume:
≥85dB@3m alarm signal

OPERATION

STATUS indicator: The STATUS indicator (green LED) is used to indicate work status of the CO alarm.
ALARM indicator: The ALARM indicator (red LED) is used to indicate alarm or warning status of the CO alarm.
TEST/RESET button: The TEST/RESET button is used to test the unit's electronics and to reset the unit during alarm.
Press and hold 0.5 seconds then release to enable the TEST/RESET button.
Start up state: When first power on, 30 seconds before the green light flash every 3 seconds, This is preheated state,
30 seconds later the green light flashing every 30 seconds indicates the unit is functioning properly
Normal operation: The green LED flashes every 30 seconds. It indicates the CO alarm is unit is functioning properly.
Malfunction warning: The red LED flashes and the horn chirps once every 35 seconds. It indicates the CO alarm is in
malfunction condition. Replace battery, if condition continues, the CO alarm has malfunctioned. Replace immediately.
The malfunction alarm will not respond CO.
Low battery voltage warning: The red LED flashes and the horn also chirps twice every 35 seconds. It indicates the
battery is low. You need to replace the battery
NOTE: The detector will not protect against the risk of carbon monoxide poisoning when the battery has drained.
End of life warning: The red LED flashes and the horn chirps 3 times every 35 seconds. It indicates end of life of CO
alarm. You need to replace the CO alarm immediately.
WARNING: After Seven(7) years from initial power up, the alarm will under the end of life warning model.
GS811-A
Product life:
Recommend ba�ery type:
Low ba�ery warning:
CO alarm silence:
7 years a�er ini�al power up
Energizer E91
Yes
about 5 minutes

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GS811-A and is the answer not in the manual?

Questions and answers

Cathy
March 26, 2025

My co status machine keeps bleeping change batteries ,no co detector Ed but keep making a loud constant bleep

1 comments:
Mr. Anderson
March 26, 2025

The GS811-A carbon monoxide detector may be beeping continuously even after changing the batteries due to the end-of-life warning. This alarm has a product life of 7 years from initial power-up. After this period, it enters the end-of-life warning mode and must be replaced immediately, as it will no longer detect carbon monoxide. If the alarm has been in end-of-life mode for more than 30 days, it cannot be silenced.

This answer is automatically generated

Kathy Christ
January 27, 2025

Why did an alarm for about 5 seconds then stopped

1 comments:
Mr. Anderson
February 10, 2025

The GS811-A alarm did not sound for only 5 seconds and stop. According to the manual, when the alarm detects a dangerous level of carbon monoxide (CO), it emits a loud alarm pattern of 4 quick beeps followed by 5 seconds of silence, repeating as long as the dangerous CO condition exists. After 4 minutes, the silence period changes to 60 seconds. If the alarm stopped after about 5 seconds, it may have been manually silenced or the CO level may have dissipated quickly.

This answer is automatically generated

Summary of Contents for Status GS811-A

  • Page 1 STATUS indicator: The STATUS indicator (green LED) is used to indicate work status of the CO alarm. ALARM indicator: The ALARM indicator (red LED) is used to indicate alarm or warning status of the CO alarm. TEST/RESET button: The TEST/RESET button is used to test the unit's electronics and to reset the unit during alarm.
  • Page 2 CO alarm warning silence: When the alarm is in the CO alarm warning, enable the TEST/RESET button, it will come into silence status for 5 minutes, and the red LED still keep flashing until the silence mode is over. NOTE: The alarm signal will reenergized within 6 minutes from the time the TEST/RESET button is operated if the concentration of CO surrounding the alarm remains at 70ppm or greater.