Do you have a question about the 3505FR Series and is the answer not in the manual?
Questions and answers
Summary of Contents for evertz 3505FR Series
Page 1
Version 1.2, February 2015 The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 3505FR Series. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the device.
Page 3
IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of un-insulated, dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (i.e.: servicing) instructions in the literature accompanying the product.
Page 4
FIBER OPTIC DEVICES Some modules in this product may have fiber optic outputs. The following safety information applies to the optical outputs of these modules. Consult individual chapters for specific safety information for handling fiber optics. WARNING CAUTION – CLASS 1 VISIBLE & INVISIBLE LASER RADIATION WHEN OPEN DO NOT VIEW DIRECTLY OR WITH OPTICAL INSTRUMENTS.
Page 5
INFORMATION TO USERS IN EUROPE NOTE This equipment with the CE marking complies with both the EMC Directive (2004/108/EC) and the Low Voltage Directive (2006/95/EC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European standards: •...
Page 6
WARNING Changes or modifications not expressly approved by Evertz Microsystems Ltd. could void the user’s authority to operate the equipment. Use of unshielded plugs or cables may cause radiation interference. Properly shielded...
Page 7
Feb 2015 Information contained in this manual is believed to be accurate and reliable. However, Evertz assumes no responsibility for the use thereof, nor for the rights of third parties, which may be affected in any way by the use thereof. Any representations in this document concerning performance of Evertz products are for informational use only and are not warranties of future performance, either expressed or implied.
Page 8
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame This page left intentionally blank Page - ii REVISION HISTORY Revision 1.2...
The 3505FR Series is a 2RU frame designed to house up to 64 Evertz® SFP modules. This provides up to 128 EO or OE in two rack units of space. The frame can be configured for a mixture of transmit, receive and distribution modules.
3505FR Series Fiber Optic SFP Frame INSTALLATION The 3505FR Series frames require 3 rack units (i.e. 3.5 inches (90 mm) of standard 19 inch (483 mm) wide rack space). To firmly fasten the frame to the equipment rack, make sure that all four mounting screws are securely tightened.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame 2.2. POWER SUPPLY STATUS INDICATORS The 3505PS power supply tray has 2 status indicator LEDs. The green status indicator LED indicates fault free operation of the PS unit. The red status indicator LED indicates a faulty 3505PS unit.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame 2.3.1. Cooling The 3505FR frame is designed to ensure adequate cooling for up to 40 watts of processing power per frame. Fans at the sides of the frame accomplish forced air cooling. Adjacent equipment may be mounted immediately to the top and bottom of the 3505FR frame.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame Figure 2-3: Cooling Fan Installation and Removal If necessary, the cooling fans can be removed for the purposes of fan replacement. Always ensure that this procedure is applied while the frame is off. Removing the fans will cause unwanted heat build-up in the 3505FR.
Evertz recommends that the user maintains a minimum bending radius of 5 cm to avoid fiber-bending loss that will decrease the maximum attainable distance of the fiber cable. For further information about care and handling of fiber optic cable see the Evertz website.
NOTE: Channels A and B on the front of the 3505FR frame correspond to channels A and B on the rear of the frame (Figure 2-8). Figure 2-7 depicts any one of the following Evertz SFP modules: 3405T13-2, 3405Txx/yy-2, 3405R-2, ®...
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame Figure 2-7: Evertz SFP Modules ® The SFP fiber modules are equipped with a class 1 laser and emit invisible radiation. Avoid exposure to the laser emitter and do not stare directly into unconnected SFP emitter ports or fiber ends that are connected to SFP ports.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame 2.5.6. Installing an SFP Module Note: In most cases, SFP modules will come from the factory preinstalled into its respective slot. The following steps outline the procedure for replacing or installing a new SFP module.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame 2.5.7. Removing an SFP Module NOTE: It is strongly recommended that SFP modules are not installed or removed with fiber-optic cables attached. Doing so may cause damage to the cables, the connectors, or the optical interfaces in the SFP module.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame NOTE: Channels A and B on the front of the 3505FR-BNC frame (Figure 2-5) correspond to channels A and B on the rear of the frame. 2.6.2. Rear Panel DIN Connections A group of 4 MiniDINs on the rear of the 3505FR-DIN are fixed and correspond to a particular SFP module.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame The following is the mapping scheme between the XLINK input/output connector pin numbers to the SFP port locations. Please note that there are three tables corresponding to use with dual receiver SFP’s, dual...
2.8. CHANGING THE FUSES If there is a fuse failure, contact Evertz customer service regarding the power supply immediately. The power supplies are short circuit protected and should not blow the fuse under a short circuit condition.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame TECHNICAL SPECIFICATIONS 3.1. 3505FR-32-BNC4 FRAME Density: Up to 64 EO, OE, or mixture of EO and OE in a 2RU unit 75 Ω Impedance: Connector: BNC per IEC 61169-8 Annex A (F-type connector optional) 3.2.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame CWDM: 1270nm-1610nm ITU-T G.694.2 compliant 3.7. OPTICAL INPUT Number of Inputs: 3505FR-32-BNC4: Up to 2 per SFP 3505FR-64-BNC2: Up to 2 per SFP 3505FR-DIN: Up to 2 per SFP 3505FR-XLINK: 2 per SFP...
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame STATUS AND LEDS The 3505FC frame controller card is inserted through the front of the frame and is secured to the 3505FR frame with the one captive screws fastened on either side of the unit.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame 4.1.2. SFP Monitoring LEDs The 16 LEDs on the front of the 3505FC signify SFP module presence and signal status (1 through 16). Description No LED An unlit LED indicates that there is no SFP plugged into the associated port number.
SNMP communications between the frame (3505FR) and the network manager (NMS), and serves as a gateway to individual SFP’s in the frame. A custom serial cable (Evertz part number: WP-DB9M- 2XDB9F-6FT) is included with each 3505FR frame and is required to configure main and redundant 3505FC.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame 5.2. VISTALINK CONFIGURATION ® NOTE: The screenshots throughout sections 5.2.1 to 5.2.3 illustrate VistaLINK ® parameters for the following SFP types: 3405T13-2, 3405T13-R, 3405R-2, 3405R-2R, and 3405OO13-DA4. 5.2.1. General Tab The General tab enables the user to view the status of various parameters such as SFP Type, Serial Number, and SFP Firmware Version.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame • SFP Type: Displays the type of SFP plugged into a particular slot. • SFP Serial Number: Displays the SFP serial number. • SFP Version: Displays the current SFP version number.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame Figure 5-10: 3405R-2R VistaLINK RX Configuration Tab ® 5.2.2.1. Tx Configuration • Laser Status: Displays the status of the laser in a SFP transmitter module. • Wavelength: Displays the wavelength of the SFP transmitter.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame Figure 5-15: 3405R-2R VistaLINK Faults Tab ® NOTE: The screenshots throughout sections 0 and 5.2.6 illustrate VistaLINK ® parameters for the 3505FC Frame Controller. 5.2.4. Network Parameters Tab The Network parameter tab enables the user to define the network parameters of the 3505FC. IP Address, Subnet Mask, Gateway Address, and Broadcast Address can be modified.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame 5.2.5. Trap Destination Tab The Trap Destination tab enables the user to define the IP address where SNMP traps will be sent. Figure 5-17: 3505FC VistaLINK Trap Destination Tab ® ...
WHAT IS VISTALINK ® VistaLINK is Evertz’s remote monitoring and configuration platform which operates over an Ethernet ® network using Simple Network Management Protocol (SNMP). SNMP is a standard computer network protocol that enables different devices sharing the same network to communicate with each other.
3505 Frame Manual 3505FR Series Fiber Optic SFP Frame 6.3. VISTALINK TRAPS ® The following traps can be enabled and monitored through the VistaLINK interface. ® Parameter Description Rx Optical Power High 1 Monitors high optical input on channel 1...