wagner solar ECOplus Installation Instructions Manual

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for wagner solar ECOplus

  • Page 1: Table Of Contents

    Wagner Solar INSTALLATION INSTRUCTIONS ECOplus Solar Storage Figure 1 ECOplus solar storage Content General Safety Notes 3 7 Install a Impressed Current Anode 1 1 Standards and Codes Startup of the System 1 2 Qualifications of the Installer 4 1 Acceptance Protocol...
  • Page 2: General Safety Notes

    Wear safety shoes and protective gloves. 1.3 Intended Use and Application Knocks and banging can cause damage to the enamel ECOplus is an enameled solar storage tank for DHW heat- coating on the inside! ing in closed circuit heating and solar installations It must...
  • Page 3 Figure 2 Scope of supply. Figure 3 Tilt the storage to insert the inner floor insulation EN-XXX_ECOplus-Solar-Storage_MA-201026-1WA10603...
  • Page 4: 3 Connecting The Domestic Water Circuit

    Installation of a filling and emptying tap at the lowest the art ● storage connection (17) Installation of an air vent (9) Part of the ECOplus con- ● Fit a thermostatic mixer (15) This assures that even nection kit, part no 139 002 07 ●...
  • Page 5: 4 Connecting The Solar- And Auxiliary Heating Circuit

    (fig 7) To do this, slightly loosen the sensor connection terminal (1), place sensor (2), and re-tighten terminal (3) Table 2 Sensor position H (mm) ECOplus 4 Auxiliary heating flow Solar sensor Auxilary heating...
  • Page 6: 7 Install A Impressed Current Anode

    3.7 Install a Impressed Current Anode 4 Startup of the System 4.1 Acceptance Protocol The installed sacrificial anode can be replaced with a maintenance free impressed current anode (optional ac- cessory, fig 8) The correct startup of the system must be certified by a Remove cable and existing magnesium anode (1), (2) qualified person in the Final Check Protocol in order ren- ●...
  • Page 7: Place The Insulation

    5 Place the Insulation The solar cylinder insulation consists of PU foam with a laminated polystyrene cover layer and hook closure (ei- ther 1 or 2 parts, depending on storage type) The higher the ambient temperature, the more flexible the PU foam and due to the breakage tendency Do not install insulation below 20 °C and allow insulation stored at cold temperatures to reach room temperature before installing...
  • Page 8: Troubleshooting

    Required cleaning of the storage tank can be carried ● out through the access/cleaning flange Install new gasket when closing! Subject to modifications, errors excepted · © Wagner Solar GmbH, 2017 · www wagner-solar com Wagner Solar GmbH · Sonnenallee 2 · D-35274 Kichhain +49 6421 80 07-0...