Download Print this page
NIVELCO NIVOCONT K User Manual

NIVELCO NIVOCONT K User Manual

Conductive level switch

Advertisement

Quick Links

Thank you for choosing a NIVELCO instrument!
1. APPLICATION
The conductive operating principle is suitable for liquids with a specific conductivity of over
10 μS / cm. The signal processor detects the resistance between the auxiliary probe and the
sensing probes. Conductive devices can only be used to decide whether the level of the mea-
sured medium is at a particular level or not. The level of detection is determined by the length
of the probe stem extending into the tank.
The level switch consists of the NIVOCONT KRK–512–5 signal processor and probes select-
ed for the particular application. The part of the probe that can be screwed into the tank is
NIVOCONT KS–0 probe head carrying one or more KLN–2 probe stems. If the
inside of the tank is coated or non-conductive, an auxiliary probe has to be installed, which is
longer than both sensing probes. If the tank's walls are conductive, they can be used as an
auxiliary probe.Conductive switches can control the filling and emptying of the tank or generic
level detection.
2. TECHNICAL DATA
2.1 GENERAL DATA
2.1.1 Switch
Probe voltage
Probe current
Sensitivity
Max. cable capacitance
Response time
Mechanical accuracy
Delay
t
delay
1
Relay output
Switching voltage
Switching current
Switching power
Min. output power DC
Mechanical life-span
Electrical life-span
Power supply U
n
Voltage range allowed
Power consumption
Ambient temperature
Electrical connection
Electrical protection
Overvoltage category*
Pollution degree
Ingress protection
Mechanical connection
Weight
*EN61010-1, tested with 3 kV
2.4 DIMENSIONS
Switch
KRK–512–
Uninsulated base probe
Probe Socket
KRK–512–
KRK–512–5
max. 3.5 V AC
< 0.1 mA AC
Adjustable: 5...100 kΩ
800 nF (5 kΩ) 100nF (100 kΩ)
max. 400 ms
±5%
Adjustable: 0.5...10 s
1.5 s
1× toggle (SPDT)
250 V AC1, 24 V DC
8 A AC1
2000 VA AC1, 240 W DC
500 mW
1 × 10
switchings
7
1 × 10
switchings
5
24...240 V AC/DC (AC 50–60 Hz)
nominal voltage –15%...+10%
max. 2 VA
−20...+55 °C (–4...+131 °F)
max. 2.5 mm
(AWG14)
2
/ with insulation 1.5 mm
(AWG16)
2
Class II
II
2
IP20
DIN (EN 60715) rail
72 g (0.16 lb)
Pg7
Cable Probe
KSK–201
2.3 ACCESSORIES
– User's Manual
– Warranty Card
– EU declaration of conformity
– Seal (2 mm [0.08"] thick)
(KLINGER OILIT):
1× ⅜" (KSP–201, KSS–201, KSN–201)
1× 1½" (KSH–20)
– M6 nut (standard SW):
3× (KSH–202)
4× (KSH–203, KSH–204)
– M6 nut (non-st. SW)
1× (KSH–204)
2.1.2 Probe sockets
KSK–
KSP–
KSS–
201
201
201
Number of probes
1
Insulation of socket
ABS
PP
M4 nut,
Cable gland
Pg7
protected by a rubber cap
Process conn.
⅜" BSP
A44
Socket material
PP
c. steel
Housing material
max. +80 °C
Medium
temperature
(+176 °F)
3 bar
Max. pressure
(43.5 psi)
Ingress protection
IP20
50 g
Mass
100 g (0.22 lb)
(0.11 lb)
r = reference probe
2.2 ORDER CODES
KRK–512–
NIVOCONT KS
Power supply
Code
Type
24...240 V AC/DC
5
Cable probe

KLN–2
PP socket
Carbon steel socket
Code
Probe length
Code
Stainless steel socket
0
0 m
0 m
0
1
1 m (3.3 ft) 0.5 m (1.64 ft)
5
Stainless steel socket
2
2 m (6.6 ft)
3
3 m (10 ft)
M20x1.5
Probe Socket
KSH–20
M20x1.5
Separator
KLP–204
KSH–
KSN–
201
202
203
204
301
302
2+r
3+r
4+r
1+r
2+r
PFA
M20x1.5
cable diameter Ø6...12 mm (Ø0.25...0.5 inch)
1½" BSP
KO35
stainless steel (1.4571)
Powder-coated
cast aluminum
max. +200 °C (+391 °F)
max. +80 °C (+176 °F)
16 bar (232 psi)
3 bar (43.5 psi)
IP65
400 g (0.88 lb)
0
Code
Housing mat. Code
K
Aluminum
SINGLE PROBE
Plastic
P
S
N
Separator:
MULTIPLE PROBES
NIVOCONT KLP–201 – for plastic version
H
NIVOCONT KLP–204 – for aluminum version
⅜" BSP
Probe Socket
KSP–201 / KSS–201 / KSN–201
Probe Socket
KSH–30
NIVOCONT K
KRK–512
CONDUCTIVE LEVEL SWITCH
USER'S MANUAL
PDF
Manufacturer:
NIVELCO Process Control Co.
H–1043 Budapest, Dugonics u. 11.
Tel.: +36-1-889-0100
Fax: +36-1-889-0200
E-mail: sales@nivelco.com
www.nivelco.com
KLN–
KLP–
KLP–
2
201
204
303
304
3+r
4+r
1
PP
M6
KO35
PP
1.4571
PBT
PP
PVDF
max.
max.
+80 °C
+130 °C
(+176 °F)
(+266 °F)
IP67
220 g/m
(0.13 lb/ft)
Probe number
Code
2
1 + reference probe*
1*
3
2 + reference probe
2
3 + reference probe
3
4 + reference probe
4
*only plastic version
Probe
KLN–2
Separator
KLP–201
krk512en1906h

Advertisement

loading

Summary of Contents for NIVELCO NIVOCONT K

  • Page 1 NIVOCONT K Thank you for choosing a NIVELCO instrument! KRK–512 1. APPLICATION 2.3 ACCESSORIES CONDUCTIVE LEVEL SWITCH – User’s Manual The conductive operating principle is suitable for liquids with a specific conductivity of over – Warranty Card 10 μS / cm. The signal processor detects the resistance between the auxiliary probe and the USER’S MANUAL...
  • Page 2 Handling Form) must be filled and enclosed in the parcel. Download it from our website www.nivelco.com. The device must be sent back with a declaration of de- contamination. A statement must be provided in the declaration that the decontam- Power supply terminals ination process was successfully completed and that the device is clean from any hazardous substances.

This manual is also suitable for:

Nivocont krk-512Nivocont krk-512-5