Table of Contents

Advertisement

Quick Links

Instruction Manual
TMS 600
SAB-C167 80C167 Microcontroller Support
070-9800-00
There are no current European directives that
apply to this product. This product provides
cable and test lead connections to a test object of
electronic measuring and test equipment.
Warning
The servicing instructions are for use by
qualified personnel only. To avoid personal
injury, do not perform any servicing unless you
are qualified to do so. Refer to all safety
summaries prior to performing service.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMS 600 SAB-C167 80C167 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tektronix TMS 600 SAB-C167 80C167

  • Page 1 Instruction Manual TMS 600 SAB-C167 80C167 Microcontroller Support 070-9800-00 There are no current European directives that apply to this product. This product provides cable and test lead connections to a test object of electronic measuring and test equipment. Warning The servicing instructions are for use by qualified personnel only.
  • Page 2 Copyright E Tektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its suppliers and are protected by United States copyright laws and international treaty provisions. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) and (2) of the...
  • Page 3 In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period. If Tektronix is unable to provide a replacement that is free from defects in materials and workmanship within a reasonable time thereafter, Customer may terminate the license for this software product and return this software product and any associated materials for credit or refund.
  • Page 4 Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
  • Page 5: Table Of Contents

    ........2–9 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 6 Using the Replaceable Mechanical Parts List ......6–1 Index TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 7 ....... 4–2 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 8 ....3–11 Table 3–12: Clock channel assignments ......3–12 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 9: General Safety Summary

    Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. Provide Proper Ventilation. Refer to the manual’s installation instructions for details on installing the product so it has proper ventilation. TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 10 CAUTION indicates a hazard to property including the product. Symbols on the Product. The following symbols may appear on the product: WARNING Protective Ground CAUTION Double High Voltage (Earth) Terminal Refer to Manual Insulated TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 11: Service Safety Summary

    Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components. To avoid electric shock, do not touch exposed connections. TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 12 Service Safety Summary viii TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 13: Preface: Microcontroller Support Documentation

    80C167 support. H The term “system under test” and “SUT” refers to the microcontroller-based system from which data will be acquired. TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 14: Logic Analyzer Documentation

    Preface: Microcontroller Support Documentation H The term “logic analyzer” refers to the Tektronix logic analyzer for which this product was purchased. H The term “module” refers to a 102/136-channel or a 96-channel module. H “80C167” refers to the SAB-C167 or the 80C167, which are two different names for the same microcontroller.
  • Page 15: Getting Started

    Getting Started...
  • Page 17: Support Description

    The TMS 600 microcontroller support package disassembles data from systems that are based on the Siemens 80C167 microcontroller. The support runs on a compatible Tektronix logic analyzer equipped with a 102/136-channel module or a 96-channel module. Refer to information on basic operations to determine how many modules and probes your logic analyzer needs to meet the minimum channel requirements for the TMS 600 microcontroller support.
  • Page 18: Logic Analyzer Software Compatibility

    Logic Analyzer Configuration To use the 80C167 support, the Tektronix logic analyzer must be equipped with either a 102/136-channel module, or a 96-channel module at a minimum. The module must be equipped with enough probes to acquire channel and clock data from signals in your 80C167-based system.
  • Page 19: Configuring The Probe Adapter

    There is one jumper on the probe adapter to select between multiplexed and demultiplexed address mode. Figure 1–1 shows the MUX/DEMUX jumper location on the probe adapter. MUX/DEMUX Jumper Figure 1–1: Jumper locations on the probe adapter 1–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 20: Connecting To A System Under Test

    3. Line up pin 1 on the 144 pin EIAJ QFP test clip, to pin 1 on the connector located on the bottom of the probe adapter circuit board, as shown in Figure 1–2. 1–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 21: Figure 1-2: Attaching The Pqfp Clip To The Probe Adapter

    Please contact the IC manufacturer to verify that the microcontroller you are connecting to conforms to the EIAJ standard. For best performance and long probe life, exercise extreme care when connecting the probe to the microcontroller. 1–5 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 22: Figure 1-3: Connecting The Probe Adapter To The Sut

    4. Place the probe adapter assembly onto the microcontroller on your SUT, as shown in Figure 1–3. Probe adapter assembly Pin 1 Microcontroller Pin 1 Figure 1–3: Connecting the probe adapter to the SUT. 1–6 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 23: Figure 1-4: Connecting The Cable To The High-Density Probe

    Center the clip on the microcontroller and apply an equal downward force on all four sides of the clip, slightly rocking the probe adapter in a clockwise circle. Do not apply leverage to the probe adapter when installing or removing it. 1–7 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 24: Without A Probe Adapter

    To connect the probes to 80C167 signals on the SUT using a test clip, follow these steps: 1. Turn off power to your SUT. It is not necessary to turn off power to the logic analyzer. 1–8 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 25: Table 1-2: 80C167 Signal Connections For Channel Probes

    D2:7 CC31IO* A2:6 D2:6 CC30IO* A2:5 D2:5 CC29IO* A2:4 D2:4 CC28IO* A2:3 D2:3 POUT3* A2:2 D2:2 POUT2* A2:1 D2:1 POUT1* A2:0 D2:0 POUT0* A1:7 D1:7 A1:6 D1:6 A1:5 D1:5 A1:4 D1:4 1–9 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 26 C0:6 P2.6* C1:5 P8.5* C0:5 P2.5* C1:4 P8.4* C0:4 P2.4* C1:3 P8.3* C0:3 P2.3* C1:2 P8.2* C0:2 P2.2* C1:1 P8.1* C0:1 P2.1* C1:0 P8.0* C0:0 P2.0* Signal not required for disassembly. 1–10 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 27: Applying And Removing Power

    To apply power to the 80C167 probe adapter and SUT, follow these steps: CAUTION. Failure to use the +5 V power supply provided by Tektronix might permanently damage the probe adapter and 80C167 microcontroller. Do not mistake another power supply that looks similar for the +5 V power supply.
  • Page 28: Figure 1-6: Location Of The Power Jack

    CAUTION. Failure to power down your SUT before removing the power from the probe adapter might permanently damage the 80C167 microcontroller and SUT. 1. Power off your SUT. 2. Unplug the power supply for the probe adapter from the electrical outlet. 1–12 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 29: Operating Basics

    Operating Basics...
  • Page 31: Setting Up The Support

    H Symbol table files The information in this section is specific to the operations and functions of the TMS 600 80C167 support on any Tektronix logic analyzer for which it can be purchased. Information on basic operations describes general tasks and functions.
  • Page 32: Write Mode

    X X 0 0 RESET signal asserted Information on basic operations describes how to use symbolic values for triggering and for displaying other channel groups symbolically, such as the Address channel group. 2–2 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 33: Acquiring And Viewing Disassembled Data

    The disassembler displays special characters and strings in the instruction mnemonics to indicate significant events. Table 2–2 shows these special characters and strings, and gives a definition of what they represent. 2–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 34: Hardware Display Format

    Used to indicate that an operand is displayed as an extension ( LOW DATA WRITE )* Used to indicate that a low byte data write operation is being used Computed cycle types. 2–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 35: Software Display Format

    Read extensions will be used to disassemble the instruction, but will not be displayed as a separate cycle in the Software display format. Data reads and writes are not displayed. 2–5 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 36: Control Flow Display Format

    H Change the interpretation of disassembled cycles H Display exception vectors There are no optional fields for this support package. Refer to the information on basic operations for descriptions of common fields. 2–6 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 37: Optional Display Selections

    Data read. Pec Read marks the current sequence as a Pec read. Flush marks the current sequence as flush. Undo Mark removes all marks from the current sequence. 2–7 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 38 Pec High Write selection. Undo Mark. If the current sequence is marked, the mark option menu will have an Undo Mark selection. Information on basic operations contains more details on marking cycles. 2–8 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 39: Displaying Exception Labels

    CC26INT CC27INT CC28INT CC29INT CC30INT CC31INT T0INT T1INT T7INT T8INT T2INT T3INT T4INT T5INT T6INT CRINT ADCINT ADEINT S0INT S0TINT S0TBINT S0RINT S0EINT SCTINT SCRINT SCEINT PWMINT XPOINT XP1INT XP2INT XP3INT 2–9 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 40 Acquiring and Viewing Disassembled Data 2–10 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 41 Specifications...
  • Page 43 All circuitry on the probe adapter is powered from the supplied power adapter. The probe adapter accommodates the Siemens SAB-C167 microcontroller in a 144-pin metric PQFP package. 3–1 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 44: Figure 3-1: Jumper Locations On The Probe Adapter

    Probe Adapter Specifications These specifications are for a probe adapter connected between a compatible Tektronix logic analyzer and a SUT. Table 3–1 shows the electrical requirements the SUT must produce for the support to acquire correct data. Table 3–2 shows the environmental specifications of the probe adapter.
  • Page 45 NOTE. In Table 3–1, for the 102/136-channel module the electrical loading on one podlet is 20 kW in parallel with 2 pF. For the 96-channel module the electrical loading on one podlet is 100 kW in parallel with 10 pF. 3–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 46: Table 3-2: Environmental Specifications

    Not to exceed 80C167 microcontroller thermal considerations. Forced air cooling might be required across the CPU. Table 3–3: Certifications and compliances EC Compliance There are no current European Directives that apply to this product. 3–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 47: Figure 3-2: Dimensions Of The Probe Adapter

    (.45 in) 113 mm (4.45 in) 25.4 mm (1.00 in) 8 mm (.300 in) 43 mm (1.70 in) Pin 1 17 mm (.65 in) Figure 3–2: Dimensions of the probe adapter 3–5 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 48: Table 3-4: Address Group Channel Assignments

    Table 3–4: Address group channel assignments order Section:channel 80C167 signal name A2:7 A2:6 A2:5 A2:4 A2:3 A2:2 A2:1 A2:0 A1:7 A1:6 A1:5 A1:4 A1:3 A1:2 A1:1 A1:0 A0:7 A0:6 A0:5 3–6 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 49: Table 3-5: Data Group Channel Assignments

    Table 3–5: Data group channel assignments order Section:channel 80C167 signal name D1:7 D1:6 D1:5 D1:4 D1:3 D1:2 D1:1 D1:0 D0:7 D0:6 D0:5 D0:4 D0:3 D0:2 D0:1 D0:0 3–7 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 50: Table 3-6: Control Group Channel Assignments

    P2.15 * A3:6 P2.14 * A3:5 P2.13 * A3:4 P2.12 * A3:3 P2.11 * A3:2 P2.10 * A3:1 P2.9 * A3:0 P2.8 * C0:7 P2.7 * C0:6 P2.6 * C0:5 P2.5 * 3–8 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 51: Table 3-8: Misc0 Group Channel Assignments

    CS4~ * C3:6 CS3~ * C3:5 CS2~ * C3:4 CS1~ * C3:3 CS0~ * C3:2 CLKOUT * C3:1 NMI~ * C3:0 EA~ * C2:3 READY~ * Signal not required for disassembly. 3–9 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 52: Table 3-9: Misc1 Group Channel Assignments

    Table 3–10: P7 (7-0) channel group assignments order Section:channel 80C167 signal name D2:7 CC31IO * D2:6 CC30IO * D2:5 CC29IO * D2:4 CC28IO * 3–10 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 53: Table 3-11: P8 (7-0) Channel Group Assignments

    80C167 signal name C1:7 P8.7 * C1:6 P8.6 * C1:5 P8.5 * C1:4 P8.4 * C1:3 P8.3 * C1:2 P8.2 * C1:1 P8.1 * C1:0 P8.0 * Signal not required for disassembly. 3–11 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 54: Table 3-12: Clock Channel Assignments

    In Custom clocking, the module clocking state machine generates one master sample for each microcontroller bus cycle, no matter how many clock cycles are contained in the bus cycle. 3–12 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 55: Figure 3-3: 80C167 Multiplexed Bus Timing

    Figure 3–3 shows the multiplexed bus timing, and the sample point and master sample point. Bus cycle Address Segment (P4) BUS (P0) Address Data BUS (P0) Address Data Sample point Master sample point Figure 3–3: 80C167 multiplexed bus timing 3–13 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 56: Figure 3-4: 80C167 Demultiplexed Bus Timing

    The sampling of the address is done at the falling edge of ALE. During a READ/FETCH cycle the data is sampled at the rising edge of RD~. During a WRITE cycle the data is sampled on the rising edge of WR~. 3–14 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 57 144 pin EIAJ QFP test clip. The pin out of the 144 pin EIAJ QFP test clip is mapped one-to-one with the pin out of the 80C167. 3–15 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 58 Specifications 3–16 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 59 WARNING The following servicing instructions are for use only by qualified personnel. To avoid injury, do not perform any servicing other than that stated in the operating instructions unless you are qualified to do so. Refer to all Safety Summaries before performing any service.
  • Page 61 Maintenance...
  • Page 63 74FCT162244ET 16-bit buffer to buffer the other signal lines between the microcontroller and the logic analyzer. Replacing Signal Leads Information on basic operations describes how to replace signal leads (individual channel and clock probes). 4–1 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 64: Figure 4-1: Location Of The Fuse

    If the fuse on the 80C167 probe adapter opens (burns out), you can replace it with a 5 A, 125 V fuse. Figure 4–1 shows the location of the fuse on the probe adapter. Fuse Figure 4–1: Location of the fuse 4–2 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 65 Replaceable Electrical Parts...
  • Page 67 TMS 600 80C167 microcontroller support. Use this list to identify and order replacement parts. Parts Ordering Information Replacement parts are available through your local Tektronix field office or representative. Changes to Tektronix products are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest improvements.
  • Page 68 Chassis-mounted parts have no assembly number prefix, and they are located at the end of the electrical parts list. Tektronix part number Use this part number when ordering replacement parts from Tektronix. 3 and 4 Serial number Column three indicates the serial number at which the part was first effective. Column four indicates the serial number at which the part was discontinued.
  • Page 69 72 VERONICA AVE SOMERSET, NJ 08873 UNIT #4 TK2449 SINGATRON ENTERPRISE CO LTD 13925 MAGNOLIA AVE CHINO, CA 91710 80009 TEKTRONIX INC 14150 SW KARL BRAUN DR BEAVERTON, OR 97077–0001 PO BOX 500 5–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 70 S3109 ORDER BY INCH,RTANG,IEC320,RCPT X STR,NEMA 15–5P,W/CORD GRIP, DESCRIPTION 174–3418–00 CA ASSY,RF:TLC,MICRO–STRIP,TLC,50 OHM,FEP,PROP DELAY 00779 1–340014–0 1.4NS,12.0 L,100 POS,PLUG,LATCHING BOT 671–3882–00 CIRCUIT BD ASSY:SAB–C167, PQFP–144, 389–2371–00 80009 671–3882–00 WIRED,TMS600 OPT 01 5–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 77 Replaceable Mechanical Parts...
  • Page 79 TMS 600 80C167 microcontroller support. Use this list to identify and order replacement parts. Parts Ordering Information Replacement parts are available through your local Tektronix field office or representative. Changes to Tektronix products are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest improvements.
  • Page 80 Items in this section are referenced by figure and index numbers to the exploded view illustrations that follow. Tektronix part number Use this part number when ordering replacement parts from Tektronix. 3 and 4 Serial number Column three indicates the serial number at which the part was first effective. Column four indicates the serial number at which the part was discontinued.
  • Page 81 91–3 COLIN DRIVE HOLBROOK, NY 11741 TK2449 SINGATRON ENTERPRISE CO LTD 13925 MAGNOLIA AVE CHINO, CA 91710 80009 TEKTRONIX INC 14150 SW KARL BRAUN DR BEAVERTON, OR 97077–0001 PO BOX 500 6–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 82 RTANG, IEC320, RCPT, AUSTRALIA, SAFETY CONTROLLED SCRIPTION (OPT A3) 161–0167–00 CA ASSY, PWR: 3, 0.75MM SQ, 250V/10AMP, 2.5 METER, S3109 ORDER BY DE- RTANG, IEC320, RCPT, SWISS, NO CORD GRIP, SAFETY SCRIPTION CONTROLLED (OPT A5) 6–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 83 Replaceable Mechanical Parts Figure 1: 80C167 probe adapter exploded view 6–5 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 84 Tektronix part Serial no. Serial no. Mfr. index number effective discont’d code number Name & description Mfr. part number 2–1 174–3418–00 CA ASSY,RF:TLC,MICRO–STRIP,TLC,50 OHM 00779 1–340014–0 Figure 2: High density probe cable 6–6 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 85 CONN, HDR CPCB, MALE, STR, 2 X 40.O.1 CTR, 0.234 MLG X 53387 131526700 0.110 TAIL, 30 GOLD (J310, J320, J330, J350, J360, J370, J410, J420, J430, J450, J460, J470, J510, J520, J530, J550, J560, J570, J610, J620, J630, J650, J660, J670) 6–7 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 86 Replaceable Mechanical Parts Figure 3: 192-Channel High-Density Probe exploded view 6–8 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 87 Index...
  • Page 89 3–12 cycle type definitions, 2–4 clock rate, 1–2 viewing, 2–3 clocking disassembler definition, ix Custom, how data is acquired, 3–12 custom, 2–1 logic analyzer configuration, 1–2 Index–1 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 90 PEC detection, 1–3 mark cycle function, 2–7 without a probe adapter, 1–8 mark opcode function, 2–7 marking cycles, definition of, 2–7 microcontroller, specific clocking and how data is acquired, 3–12 Index–2 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 91 2–3 channel assignments, 3–6 compliances, 3–4 electrical, 3–2 environmental, 3–4 write configuration, mode of operation, 2–7 mechanical (dimensions), 3–5 write mode, clocking option, 2–2 subroutine display format, 2–6 Index–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
  • Page 92 Index Index–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...