Summary of Contents for Tektronix TMS 600 SAB-C167 80C167
Page 1
Instruction Manual TMS 600 SAB-C167 80C167 Microcontroller Support 070-9800-00 There are no current European directives that apply to this product. This product provides cable and test lead connections to a test object of electronic measuring and test equipment. Warning The servicing instructions are for use by qualified personnel only.
Page 2
Copyright E Tektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its suppliers and are protected by United States copyright laws and international treaty provisions. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) and (2) of the...
Page 3
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period. If Tektronix is unable to provide a replacement that is free from defects in materials and workmanship within a reasonable time thereafter, Customer may terminate the license for this software product and return this software product and any associated materials for credit or refund.
Page 4
Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. Provide Proper Ventilation. Refer to the manual’s installation instructions for details on installing the product so it has proper ventilation. TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 10
CAUTION indicates a hazard to property including the product. Symbols on the Product. The following symbols may appear on the product: WARNING Protective Ground CAUTION Double High Voltage (Earth) Terminal Refer to Manual Insulated TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components. To avoid electric shock, do not touch exposed connections. TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 12
Service Safety Summary viii TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
80C167 support. H The term “system under test” and “SUT” refers to the microcontroller-based system from which data will be acquired. TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Preface: Microcontroller Support Documentation H The term “logic analyzer” refers to the Tektronix logic analyzer for which this product was purchased. H The term “module” refers to a 102/136-channel or a 96-channel module. H “80C167” refers to the SAB-C167 or the 80C167, which are two different names for the same microcontroller.
The TMS 600 microcontroller support package disassembles data from systems that are based on the Siemens 80C167 microcontroller. The support runs on a compatible Tektronix logic analyzer equipped with a 102/136-channel module or a 96-channel module. Refer to information on basic operations to determine how many modules and probes your logic analyzer needs to meet the minimum channel requirements for the TMS 600 microcontroller support.
Logic Analyzer Configuration To use the 80C167 support, the Tektronix logic analyzer must be equipped with either a 102/136-channel module, or a 96-channel module at a minimum. The module must be equipped with enough probes to acquire channel and clock data from signals in your 80C167-based system.
There is one jumper on the probe adapter to select between multiplexed and demultiplexed address mode. Figure 1–1 shows the MUX/DEMUX jumper location on the probe adapter. MUX/DEMUX Jumper Figure 1–1: Jumper locations on the probe adapter 1–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
3. Line up pin 1 on the 144 pin EIAJ QFP test clip, to pin 1 on the connector located on the bottom of the probe adapter circuit board, as shown in Figure 1–2. 1–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Please contact the IC manufacturer to verify that the microcontroller you are connecting to conforms to the EIAJ standard. For best performance and long probe life, exercise extreme care when connecting the probe to the microcontroller. 1–5 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
4. Place the probe adapter assembly onto the microcontroller on your SUT, as shown in Figure 1–3. Probe adapter assembly Pin 1 Microcontroller Pin 1 Figure 1–3: Connecting the probe adapter to the SUT. 1–6 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Center the clip on the microcontroller and apply an equal downward force on all four sides of the clip, slightly rocking the probe adapter in a clockwise circle. Do not apply leverage to the probe adapter when installing or removing it. 1–7 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
To connect the probes to 80C167 signals on the SUT using a test clip, follow these steps: 1. Turn off power to your SUT. It is not necessary to turn off power to the logic analyzer. 1–8 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
To apply power to the 80C167 probe adapter and SUT, follow these steps: CAUTION. Failure to use the +5 V power supply provided by Tektronix might permanently damage the probe adapter and 80C167 microcontroller. Do not mistake another power supply that looks similar for the +5 V power supply.
CAUTION. Failure to power down your SUT before removing the power from the probe adapter might permanently damage the 80C167 microcontroller and SUT. 1. Power off your SUT. 2. Unplug the power supply for the probe adapter from the electrical outlet. 1–12 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
H Symbol table files The information in this section is specific to the operations and functions of the TMS 600 80C167 support on any Tektronix logic analyzer for which it can be purchased. Information on basic operations describes general tasks and functions.
X X 0 0 RESET signal asserted Information on basic operations describes how to use symbolic values for triggering and for displaying other channel groups symbolically, such as the Address channel group. 2–2 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
The disassembler displays special characters and strings in the instruction mnemonics to indicate significant events. Table 2–2 shows these special characters and strings, and gives a definition of what they represent. 2–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Used to indicate that an operand is displayed as an extension ( LOW DATA WRITE )* Used to indicate that a low byte data write operation is being used Computed cycle types. 2–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Read extensions will be used to disassemble the instruction, but will not be displayed as a separate cycle in the Software display format. Data reads and writes are not displayed. 2–5 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
H Change the interpretation of disassembled cycles H Display exception vectors There are no optional fields for this support package. Refer to the information on basic operations for descriptions of common fields. 2–6 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Data read. Pec Read marks the current sequence as a Pec read. Flush marks the current sequence as flush. Undo Mark removes all marks from the current sequence. 2–7 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 38
Pec High Write selection. Undo Mark. If the current sequence is marked, the mark option menu will have an Undo Mark selection. Information on basic operations contains more details on marking cycles. 2–8 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 43
All circuitry on the probe adapter is powered from the supplied power adapter. The probe adapter accommodates the Siemens SAB-C167 microcontroller in a 144-pin metric PQFP package. 3–1 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Probe Adapter Specifications These specifications are for a probe adapter connected between a compatible Tektronix logic analyzer and a SUT. Table 3–1 shows the electrical requirements the SUT must produce for the support to acquire correct data. Table 3–2 shows the environmental specifications of the probe adapter.
Page 45
NOTE. In Table 3–1, for the 102/136-channel module the electrical loading on one podlet is 20 kW in parallel with 2 pF. For the 96-channel module the electrical loading on one podlet is 100 kW in parallel with 10 pF. 3–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Not to exceed 80C167 microcontroller thermal considerations. Forced air cooling might be required across the CPU. Table 3–3: Certifications and compliances EC Compliance There are no current European Directives that apply to this product. 3–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
(.45 in) 113 mm (4.45 in) 25.4 mm (1.00 in) 8 mm (.300 in) 43 mm (1.70 in) Pin 1 17 mm (.65 in) Figure 3–2: Dimensions of the probe adapter 3–5 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
In Custom clocking, the module clocking state machine generates one master sample for each microcontroller bus cycle, no matter how many clock cycles are contained in the bus cycle. 3–12 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Figure 3–3 shows the multiplexed bus timing, and the sample point and master sample point. Bus cycle Address Segment (P4) BUS (P0) Address Data BUS (P0) Address Data Sample point Master sample point Figure 3–3: 80C167 multiplexed bus timing 3–13 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
The sampling of the address is done at the falling edge of ALE. During a READ/FETCH cycle the data is sampled at the rising edge of RD~. During a WRITE cycle the data is sampled on the rising edge of WR~. 3–14 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 57
144 pin EIAJ QFP test clip. The pin out of the 144 pin EIAJ QFP test clip is mapped one-to-one with the pin out of the 80C167. 3–15 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 59
WARNING The following servicing instructions are for use only by qualified personnel. To avoid injury, do not perform any servicing other than that stated in the operating instructions unless you are qualified to do so. Refer to all Safety Summaries before performing any service.
Page 63
74FCT162244ET 16-bit buffer to buffer the other signal lines between the microcontroller and the logic analyzer. Replacing Signal Leads Information on basic operations describes how to replace signal leads (individual channel and clock probes). 4–1 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
If the fuse on the 80C167 probe adapter opens (burns out), you can replace it with a 5 A, 125 V fuse. Figure 4–1 shows the location of the fuse on the probe adapter. Fuse Figure 4–1: Location of the fuse 4–2 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 67
TMS 600 80C167 microcontroller support. Use this list to identify and order replacement parts. Parts Ordering Information Replacement parts are available through your local Tektronix field office or representative. Changes to Tektronix products are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest improvements.
Page 68
Chassis-mounted parts have no assembly number prefix, and they are located at the end of the electrical parts list. Tektronix part number Use this part number when ordering replacement parts from Tektronix. 3 and 4 Serial number Column three indicates the serial number at which the part was first effective. Column four indicates the serial number at which the part was discontinued.
Page 69
72 VERONICA AVE SOMERSET, NJ 08873 UNIT #4 TK2449 SINGATRON ENTERPRISE CO LTD 13925 MAGNOLIA AVE CHINO, CA 91710 80009 TEKTRONIX INC 14150 SW KARL BRAUN DR BEAVERTON, OR 97077–0001 PO BOX 500 5–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 70
S3109 ORDER BY INCH,RTANG,IEC320,RCPT X STR,NEMA 15–5P,W/CORD GRIP, DESCRIPTION 174–3418–00 CA ASSY,RF:TLC,MICRO–STRIP,TLC,50 OHM,FEP,PROP DELAY 00779 1–340014–0 1.4NS,12.0 L,100 POS,PLUG,LATCHING BOT 671–3882–00 CIRCUIT BD ASSY:SAB–C167, PQFP–144, 389–2371–00 80009 671–3882–00 WIRED,TMS600 OPT 01 5–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 79
TMS 600 80C167 microcontroller support. Use this list to identify and order replacement parts. Parts Ordering Information Replacement parts are available through your local Tektronix field office or representative. Changes to Tektronix products are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest improvements.
Page 80
Items in this section are referenced by figure and index numbers to the exploded view illustrations that follow. Tektronix part number Use this part number when ordering replacement parts from Tektronix. 3 and 4 Serial number Column three indicates the serial number at which the part was first effective. Column four indicates the serial number at which the part was discontinued.
Page 81
91–3 COLIN DRIVE HOLBROOK, NY 11741 TK2449 SINGATRON ENTERPRISE CO LTD 13925 MAGNOLIA AVE CHINO, CA 91710 80009 TEKTRONIX INC 14150 SW KARL BRAUN DR BEAVERTON, OR 97077–0001 PO BOX 500 6–3 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 82
RTANG, IEC320, RCPT, AUSTRALIA, SAFETY CONTROLLED SCRIPTION (OPT A3) 161–0167–00 CA ASSY, PWR: 3, 0.75MM SQ, 250V/10AMP, 2.5 METER, S3109 ORDER BY DE- RTANG, IEC320, RCPT, SWISS, NO CORD GRIP, SAFETY SCRIPTION CONTROLLED (OPT A5) 6–4 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 84
Tektronix part Serial no. Serial no. Mfr. index number effective discont’d code number Name & description Mfr. part number 2–1 174–3418–00 CA ASSY,RF:TLC,MICRO–STRIP,TLC,50 OHM 00779 1–340014–0 Figure 2: High density probe cable 6–6 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 89
3–12 cycle type definitions, 2–4 clock rate, 1–2 viewing, 2–3 clocking disassembler definition, ix Custom, how data is acquired, 3–12 custom, 2–1 logic analyzer configuration, 1–2 Index–1 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Page 90
PEC detection, 1–3 mark cycle function, 2–7 without a probe adapter, 1–8 mark opcode function, 2–7 marking cycles, definition of, 2–7 microcontroller, specific clocking and how data is acquired, 3–12 Index–2 TMS 600 SAB-C167 80C167 Microcontroller Support Instruction Manual...
Need help?
Do you have a question about the TMS 600 SAB-C167 80C167 and is the answer not in the manual?
Questions and answers