Page 2
The quick recovery time makes this system one of the few times that temperature setback makes sense in radiant floor heating. These are just some of the advantages you will receive from the ® intelligent design and high quality of the Roth Radiant Panel System...
Page 3
The floor panel system has a normal operating range of 60-140°F (15-60°C), depending on the radiant heating system design and finished floor material. Underlayment, vapor barriers, water- proof membranes, etc. should be selected with the actual operating temperatures in mind. Be sure to discuss the design parameters with the flooring contractor prior to installation.
Page 4
5A.3 Installation of the Panel The sub-floor must be smooth, clean and level. Surface irregularities should not exceed more than 0.02" per foot. The Roth Radiant Panel System countersunk screws or a foam board compatible adhesive. Apply the adhesive according to the manufacturer’s instructions.
Page 5
5A. INSTALLATION INSTRUCTIONS Continue to lay the master panels. When cutting the master panels, mark the plate and saw it with EPS side up. You can use any saw with a fine-toothed metal blade. After cutting the panel, remove any burrs. When cutting the last master panel in the first row, use the rest of the panel to start the next row.
Page 6
5A. INSTALLATION INSTRUCTIONS 5A.4 Installation of PEX-tubing Start the tubing installation by connecting the PEX tubing to the manifold. Loops can be pre-cut if you have figured the correct leader length (from the manifold to the actual heated area) when designing the system with our software.
Page 7
It is also a good idea to use plasticizer additives with the mastic and grout for more flexibility during operation of the heating system. Laminate Wood Flooring: Thin laminate flooring may require the use of an underlayment material to provide additional support above the tubing/grooves.
Page 8
Roth's success is the result of flexibility in products, targeted investments and theme oriented solutions. Our growth stems from continuous research and development of new and innovative products. Manufacturing keys to success are combinations of know-how, modern production sites and equipment, latest production technologies, and motivated personnel.