Page 1
High End User Panel HXV 5 Service manual Rev. 2.0...
Page 2
Der tages forbehold for trykfejl og ændringer Dantherm can accept no responsibility for possible errors and changes Irrtümer und Änderungen vorbehalten Dantherm n’assume aucune responsabilité pour erreurs et modifications éventuelles...
Page 3
Introduction Overview Introduction This is the installation and users instruction for the Dantherm Air Handling High End User’s Panel for the HXV 5 unit. The table of content below gives you an overview of the subjects. Copyright Copying of this service manual, or part of it, is forbidden without prior written permis- sion from Dantherm Air Handling.
Page 4
Up to 5 High End User’s Panels can be connected at the same time. Information about operation can be read on the display. The basic panel for HXV 5 cannot be used when the High End User’s Panel is installed. Illustration This illustrates the High End User’s...
Page 5
HXV 5 High End User Panel to the last serial connected user panel Connect the 12 meter cable from the High End User Panel to the cable from the HXV 5 that was previously con- nected to the basic user panel...
Page 6
User’s guide Introduction This topic will guide through customization of different settings. Displays Displays shown in this manual is often examples and may differ from one display to an- other. More than one high By use of more than one high end user panel, the following should be done: end user panel, ad- When the panel is installed it requests for its address.
Page 7
User’s guide, continued Read settings Follow this procedure to read settings: Step Action Result Press Enter to reach the menu Press arrow down to read the different settings/values A complete menu structure is available in section “Menu struc- ture and factory settings”, page Press Key Lock twice to escape the menu Change of settings...
Page 8
The function disables the exhaust air fan for 15 minutes by which the inlet fan estab- lishes an over pressure in the house, which is good for the vent in the chimney. Reset filter timer See the service manual for HXV 5.
Solution Display shows FIRE AQ sensor has detected a Stop the HXV 5 value on or below 5 Reset HXV 5 by discon- necting it for a few sec- onds Buzzer sounds Filter timer is below val- Replace/clean the filter...
Page 10
Menu structure and factory settings Menu structure The following table shows the complete menu structure in the panel. The factory set- tings (if any) of each menu item and the range is also available from the table: Menu Display Factory setting Range Fan speed 1 40 %...
Page 11
+(0) 121 133 70 infodk@dantherm.com dantherm.no@dantherm.com infose@dantherm.com www.dantherm.com www.dantherm.no www.dantherm.se Dantherm Air Handling (Suzhou) Ltd. Dantherm Limited Dantherm Air Handling Inc. Bldg#9, No.855 Zhu Jiang Rd., 12 Windmill Business Park 110 Corporate Drive, Suite K Suzhou New District, Jiangsu Windmill Road, Clevedon...