Many thanks for choosing a product of TechniSat Digital GmbH. The following quick start set up guide will help you installing your heating thermostat HT2. Please read this manual carefully before using and keep it around when installing the product. For questions and information please contact your TechniSat reseller / distributor or use our technical hotline via +49 3925/9220 1800.
Included in delivery 1 Heating thermostat HT2 2 Screw 3 Adapters for Danfoss valves 2x AA batteries *When using the RAV adapter you need to use the RAV Pin for the extension of the valve stem. 2 IMPORTANT INSTRUCTIONS! WARNING- Do not use rechargeable batteries! Never recharge batteries, do not short circuit them, do not take them apart –...
3 Product description The heating thermostat HT2 is a Z-Wave plus radio standard compatible energy saving radiator thermostat. FLiRS (Frequently Listening Receiver Slave): The heating thermostate HT2 uses FLiRS to provide short latency and short responding times. Technical specifications Device: Heating Thermostate HT2...
Battery: Lights up if less than 15% battery is remaining Lock: Lights up if child protection is set Celsius: Displayed if the LCD shows a setpoint temperature Percent: Displayed instead of C Icon if the HT2 is set to direct control mode...
Inserting batteries Remove the battery cover by simply pulling it off. Now insert the batteries. Pay attention to the correct polarity! At a later battery change, the configuration of your HT2 is maintained. 4.4 Inclusion Start inclusion mode of your primary Z-Wave controller.
Page 8
4.5 Mounting the heating thermostat HT2 After adding the HT2 to a network it is ready to be installed on the radiator. The LCD shows INS. Do not press the boost button yet. If successfully installed to the radiator proceed with 4.6.
HT2 for at least 5 seconds. 4.8 Unmounting the heating thermostat HT2 Remove the HT2 from the Z-Wave network before unmounting it. Follow the process described in Exclusion and wait until the LCD shows INC. You can now uninstall the HT 2 from the radiator.
5.2 Child protection Press and hold plus and minus button simultaneously for 3 seconds to enable/disable the child protection. If the HT2 is set into the highest protection level it is no longer possible to operate the device locally. 5.3 Altering the operating states Off-Mode Press minus button until OFF is displayed.
5.5 Display NodeID Press and hold the boost button for 3 seconds to display the NodeID. 6 Z-Wave *Availability of the Command Class after adding the heating thermostat HT2 to your Z-Wave network. U Unsecure S0 Z-Wave Security standard S0...
6.1 Association Heating thermostat HT2 can only be associated with the Z-Wave controller 6.2 Basic Control basic functions of the heating thermostat HT2 via basic command class.
Per default the reporting threshold is +/-0.5 C. This parameter can be altered via configuration command class. The measured room temperature can be adjusted with an offset. The heating thermostat HT2 can receive temperature readings from other Z-Wave devices (wall thermostat for example). The external temperature can be used for temperature regulation.
Controlling the valve directly via multilevel switch command class is only possible if the heating thermostat HT2 is in manufacturer specific mode 6.6 Notification Heating thermostat HT2 will send notifications on certain events. 6.7 Protection Heating thermostat HT2 can be locked remotely.
6.9 Thermostat set point The following set points of the heating thermostat HT2 can be altered. 7.0 Troubleshooting Replace batteries Adjust temperature of the boiler water. Remove the HT2, move the valve back and forth per hand or with a tool Unmount HT2.