20
Quick start for the Cellpro Multi4 Charger
Refer to manual for complete operating details.
A. Connect charger to a 12V to 16V (maximum), 5A power source.
B. At Welcome screen, press Mode button to display Preset Menu.
C. In Preset Menu, press Mode button to display User Preset for pack you want to charge.
D. Connect pack to charger.
E. Press and hold Mode button. When you see START CHARGE, release Mode button. Display
briefl y shows CHECKING PACK.
F. Next screen displays preset's chemistry and prompts you to verify it is same as pack's chem-
istry. This is a safety check.
If displayed chemistry matches pack chemistry, press Mode button to start charging. Go
to step G.
or
If displayed chemistry does not match pack chemistry, do nothing. Screen will time out
and Preset Menu will be displayed. Go to step C.
G. During charging:
Press Mode button to view charging data screens.
To stop charging:
a. Press and hold Mode button to see STOP CHARGE? >No.
b. Press Mode button to see STOP CHARGE? >Yes. Press and hold Mode button.
c. When you see CHARGER STOPPED, press Mode button to see Preset Menu (step C).
H. When charging is complete, charger beeps three times repeatedly and displays ELAPSED
[time] / [chemistry] DONE. Press Mode button to review charging data screens.
I. Disconnect pack from charger. Display shows PACK REMOVED.
J. Press Mode button to return to Preset Menu.
FMA limited warranty
FMA, Inc. warrants this product to be free of manufacturing defects for the term of one year from the date of pur-
chase. Should any defects covered by this warranty occur, the product shall be repaired or replaced with a unit of
equal performance by FMA or an authorized FMA service station.
Limits and exclusions
This warranty may be enforced only by the original purchaser, who uses this product in its original condition as
purchased, in strict accordance with the product's instructions. Units returned for warranty service to an FMA
service center will be accepted for service when shipped postpaid, with a copy of the original sales receipt or war-
ranty registration form, to the service station designated by FMA.
This warranty does not apply to:
Consequential or incidental losses resulting from the use of this product.
Damage resulting from accident, misuse, abuse, neglect, electrical surges, reversed polarity on connectors,
lightning or other acts of God.
Damage from failure to follow instructions supplied with the product.
Damage occurring during shipment of the product either to the customer or from the customer for service
(claims must be presented to the carrier).
Damage resulting from repair, adjustment, or any alteration of the product by anyone other than an authorized
FMA technician.
Installation or removal charges, or damage caused by improper installation or removal.
Call (301) 668-4280 for more information about service and warranty repairs.
Features
Simple to operate: just connect the Cellpro Multi4 Charger between a power source and
a pack, select a pack-specifi c preset and start charging. No jumpers, plugs or dials to set!
Charger automatically determines pack capacity and sets optimal current, then dynamically
adjusts charge rate as needed. Manual charge rates up to 4.0A allow for special situations.
Charges LiPo, Li-Ion, LiFePO4, A123©, LiMn, NiCd, NiMH and Lead Acid chemistries
(adapters for many node connector types are available from FMA Direct). Supports both bal-
anced (depending on chemistry) and non-balanced charging (with certain safety limitations).
Charger holds up to 25 user confi gurable presets (User Presets), optimized for the different
chemistries, providing charging strategies for most common RC charging needs. Charger also
holds up to 50 Library Presets. When using the free Charge Control Software, the number of
custom presets is virtually unlimited and will grow over time to meet industry needs. Replace
and customize presets to match your battery inventory.
Charges Lithium (2s to 4s balanced charge, 1s to 2s unbalanced charge) and A123 packs (2s
to 4s balanced, 1s to 5s unbalanced) in any capacity up to 32Ah. During balanced charging,
each cell is charged independently, providing exceptional charging safety and elevating RC
packs to the safety level of cellphones. Typical packs of up to 4Ah capacity charge in 50
minutes or less using charger's 2C Auto Current Mode.
Latest technology provides the ultimate in safety—even charges packs having hidden physical
damage without danger of fi re. A pack will not charge if individual cell voltages don't equal
total pack voltage.
Cell balancing to 5mV and automatic overcharge protection assure longest pack life. Auto-
matic temperature monitoring prevents pack overcharging at low ambient temperatures and
charger damage at high ambient temperatures.
Multifunction backlit display lets you select presets, replace default presets from a library
and shows charging data such as individual cell voltages, charge current, supply voltage, and
amount of charge (mAh) put into pack. Plus, the unique Fuel display shows percent capacity
in a pack.
Charge Control Software (CCS, a free download) allows you to customize, save and load pre-
sets (including charger data displays), and view real-time charging data and graphs. CCS also
manages fi rmware updates to keep your charger operating smoothly.
Operates from any 10–16V DC power source. Inputs and outputs are protected against re-
verse polarity.
Precautions
Follow all instructions in this manual to assure safe operation.
Always watch LiPo packs while they are charging. Never leave LiPo packs unsupervised
during charging.
See additional warning sheets provided with this charger and FMA LiPo packs.
Follow all guidelines for charging, discharging, handling and storing packs of all kinds.
FMA, Inc.
5713 Industry Lane, Suite 50
Sales: (800) 343-2934
090126
Cellpro Multi4 Charger
Model LC04S04A-MC, for use with LiPo, Li-Ion, A123,
NiCd, NiMH and Lead Acid battery packs
Automatic and manual charge rates at up to 4A with
overcharge protection and cell balancing (for packs with
node connectors)
Frederick, MD 21704
Technical: (301) 668-4280
www.fmadirect.com

Advertisement

loading

Summary of Contents for FMA Cellpro Multi4

  • Page 1 FMA limited warranty in a pack. FMA, Inc. warrants this product to be free of manufacturing defects for the term of one year from the date of pur-  Charge Control Software (CCS, a free download) allows you to customize, save and load pre- chase.
  • Page 2: Connecting The Charger

    Unknown Chemistry node connector, the FMA CPBP7 LiPo Pack Node Connector cable assembly will make the Charge Timeout pack compatible with the Cellpro Multi4 Charger. The diagrams below show how the Node No Charge Screens to Show Cell Cnt Changed Connector attaches to packs of various confi...
  • Page 3: Estimating Performance Factors

    fi ve Empty Presets. In many cases, you can simply select the User Cellpro Multi4 Charger enables you to estimate them using before- and after-fl ight measure- Preset that matches the pack you want to charge, connect the pack and start charging.
  • Page 4 Capacity added to pack: ±1% Percent capacity (“Fuel”): ±5% Serial data output 19.2kbps, 8 bits, 1 start bit, 1 stop bit, no parity *charger can be used with balanced 2s to 4s packs having a node connector (an appropriate FMA adapter may be required)
  • Page 5 Press Charging PACK REMOVED [various charge Elapsed [time] Disconnect Press Updating charger fi rmware pack from data screens] [chemistry] DONE The Charge Control Software automatically checks for new fi rmware each time it is launched charger (assuming the computer is connected to the Internet). If new fi rmware is available, it is down- loaded to your computer.
  • Page 6 Changing a User Preset’s charge rate You can change the charge rate for any User Preset. The new rate is retained (even after power is Monitoring charging operations cycled) until you change it again (this behavior can be changed via Charge Control Software). ...
  • Page 7: Using The Charge Control Software

    Using the Charge Control Software Other User Preset operations The free Cellpro Multi4 Charge Control Software (CCS) gives you unparalleled ability to cus-  To remove a User Preset: See “Clearing a User Preset.” Thereafter, that slot will show EMP- tomize your charger.
  • Page 8 Factory-installed User Presets Storing packs LiPo Generic Accurate Charge. Basic LiPo preset can be used for any LiPo battery. Fuel Table is optimized for generic LiPo batteries from C discharge ratings up to 20C.  For best results, LiPo and A123 packs should be stored at 50% of capacity. Use the charger’s Selectable charge rates include 1C, 2C, 3C AUTO or 0.25A to 4.0A manual.
  • Page 9 Selectable charge rates include 1C, 2C, 3C AUTO a pack before charging it. Go from fl ying to charging to fl ying again without waiting. FMA or 0.25A to 4.0A manual. Optimization is for the most accurate charging with cell-balancing chargers are the only ones that can charge a pack immediately after discharge termination settings of C/20 and max of 30 min timeout for C.V.
  • Page 10 As an example of how preset parameters affect the charging process, each Auto mode preset 21 EMPTY PRESET. May be populated with any preset from the charger library or the FMA PC includes a Fuel Table unique to a specifi c battery chemistry. When you select a User Preset for library.