ATCP SONELASTIC SA-BC Installation And Operation Manual

Adjustable support for bars and cylinders

Advertisement

Quick Links

Installation and Operation Manual
SA-BC
Adjustable support for bars and cylinders
ATCP Physical Engineering, Sonelastic
Division
Lêda Vassimon, 735-A - Ribeirão Preto - Brazil - 14026-567
Telephone: +55 (16) 3289-9481
www.sonelastic.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SONELASTIC SA-BC and is the answer not in the manual?

Questions and answers

Summary of Contents for ATCP SONELASTIC SA-BC

  • Page 1 Installation and Operation Manual SA-BC Adjustable support for bars and cylinders ATCP Physical Engineering, Sonelastic  Division Lêda Vassimon, 735-A - Ribeirão Preto - Brazil - 14026-567 Telephone: +55 (16) 3289-9481 www.sonelastic.com...
  • Page 2 SA-BC Adjustable support for bars and cylinders Installation and Operation Manual SA-BC Adjustable support for bars and cylinders Manufactured by: ATCP do Brasil – Alves Teodoro Cerâmicas Piezoelétricas do Brasil Ltda. ATCP Physical Engineering, Sonelastic  Division Rua Lêda Vassimon, 735-A Ribeirão Preto –...
  • Page 3 Copyright Copyright © 2010-2022 by ATCP Physical Engineering All rights reserved. ATCP reserves the right to change the product or this manual without notice. Version 6.0 April/2022...
  • Page 4: Table Of Contents

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders TABLE OF CONTENTS 1. Introduction ....................05 2. Definitions ....................05 3. Features and applications ................05 4. Configurations, parts, accessories and optional items ........06 5. Parts identification ..................08 6.
  • Page 5: Introduction

    SA-BC Adjustable support for bars and cylinders 1. Introduction ATCP Physical Engineering equipment and products were projected and manufactured to provide a long-lasting and top-rated performance. This Installation and Operation Manual contains all necessary information regarding the use and maintenance of SA-BC Support.
  • Page 6: Configurations, Parts, Accessories And Optional Items

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 4. Configurations, parts, accessories and optional items SA-BC Support is available in both manual and automatic configurations. Optional items are offered to customize the Sonelastic ® Systems. Manual configuration Parts: Optional Items: [01] –...
  • Page 7 Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Automatic configuration Parts: Optional Items: [01] – SA-BC Support; [03] – Sturdy Tripod. [02] – CA-PD Acoustic Sensor. Accessories: [04] - Spare Support-cable set; [05] - Height-adjusting disc for the CA-PD Acoustic Sensor; [06] - IED Automatic Impulse Device control unit;...
  • Page 8: Parts Identification

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 5. Parts identification SA-BC Support 01- Support base; 02- Support-cable tightener; 03- Support-cable; 04- Safety cables; 05- Support bar; 06- Anchoring terminal; 07- Leveling foot. * Two sets of cables are provided: a Ø1.2 mm cable, for heavier specimens, and a Ø0.7mm cable, for lighter specimens.
  • Page 9: Specifications

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Sturdy Tripod 01- Frame; 02- Articulated tripod; 03- Handle for securing the tube; 04- Pillar; 05- Handle for the tube articulation; 06- Acoustic sensor clip; 07- Inner tube; 08- Handle for the inner tube articulation; 09- Outer tube;...
  • Page 10: Specimens

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 7. Specimens 7.1 Recommended aspect ratios and typical dimensions Minimum aspect ratios must be observed to avoid coupling between specimen’s vibration modes. In addition, aspect ratio determines the pattern of frequency spectrum of the acoustic response.
  • Page 11: Placing The Specimen

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 7.2 Placing the specimen The specimen should be symmetrically placed over the support-cables, with those at a distance of 0.224 L from the specimen ends (L is the specimen length). For instance, if a specimen’s length (L) is 100 mm, the support-cables should be positioned at a distance of 22.4 mm from the ends.
  • Page 12: Typical Arrangements

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 8.2 Typical arrangements Typical SA-BC Support arrangements are presented next. Configuration: Manual. Specimen: Square section bar. Acoustic sensor: With vertical mounting base and the height-adjusting disc. Impulse device: Light Manual Impulse Device.
  • Page 13 Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Configuration: Manual. Specimen: Heavy cylinder. Acoustic sensor: With vertical mounting base, but without the height-adjusting disc. Impulse device: Medium Manual Impulse Device. Configuration: Automatic Specimen: Heavy cylinder. Acoustic sensor: With vertical mounting base.
  • Page 14: Mounting The Acoustic Sensor In The Vertical Base And Sturdy Tripod

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 8.3 Mounting the acoustic sensor in the vertical base and Sturdy Tripod In the vertical mounting base: Step 01 - Insert the acoustic sensor in the vertical mounting base ensuring the wire goes out through the side opening, as shown below: Step 02 - Press the base against the acoustic sensor until it is coupled and secured to the...
  • Page 15: Replacing The Support-Cables

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 8.4 Replacing the support-cables The thinner the support-cable, the smaller is its interference in the measurement. However, observe the maximum weight than can be held by each of the two support-cables available. SA-BC Support is supplied with a Ø1.20mm support-cable set (this is the recommended cables to be used with specimens weighting between 10 and 30kg).
  • Page 16: Installing The Ied Automatic Impulse Device

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders For light specimens (weighting up to 10kg), tension the support-cables until fully straight. For heavy specimens, adjust the tension on the cables so that, when the specimen is placed over them, it will only go down about 15 mm from its initial position, as shown below: Necessary displacement for heavy specimens using Ø1,20...
  • Page 17: Support Operation

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 9. Support operation After following 8 – Support Installation steps, the SA-BC Support will ready for use. 9.1 Positioning the specimen To carry out a fast and precise characterization of specimens using SA-BC Support: Step 01: Install the support according to the specimen weight (see 8 –...
  • Page 18: Positioning The Acoustic Sensor

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 9.2 Positioning the acoustic sensor Step 01: Mount the acoustic sensor in the Sturdy Tripod clip or in the vertical mounting base, as described in 8.3 – Mounting the acoustic sensor in the vertical base and on the Sturdy Tripod;...
  • Page 19 Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Step 03: Configure the Impulse Device intensity (see more information in the IED Impulse Device User Manual. Note: All information regarding the IED Automatic Electromagnetic Impulse Device has been described in detail in its Installation and Operation Manual. Attention! When dealing with heavy specimens, ensure safety cables are always positioned close by the support-cables to avoid chances of specimens falling over the user hands in the case of a support-cable...
  • Page 20: Acquisition And Excitation Modes

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 10. Acquisition and excitation modes The table below describes the most practical positions of the acoustic sensor and impulse device for characterizing rectangular specimens, using flexural, torsional and longitudinal vibration modes. Flexural mode –...
  • Page 21 Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders The next table provides additional information focused on cylindrical specimens. Flexural mode - I Excitation from above and signal acquisition from below, both aligned with the center of the specimen. Cables positioned at 0.224 L.
  • Page 22: Warnings And Support Transportation

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 11. Warnings and support transportation Reading all the information contained in this Installation and Operation Manual is compulsory for the correct use of the support; The power outlet where the computer will be connected must have a functional ground pin;...
  • Page 23: Symbology

    If the support presents any abnormality, verify if the problem is listed in 12 – Maintenance and troubleshooting. If the problem still cannot be fixed, contact ATCP. ATCP Physical Engineering offers a 12-month warranty with this support, starting from the date of purchase. It covers manufacturing defects or materials defects, but some factors may...
  • Page 24: Notes

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Notes: ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................Pág. 24 de 24...

Table of Contents