Scope
This guide provides basic instructions for installing, configuring and adding cards to the
CRC100R Controller. For detailed CRC100R user information, refer to the User Guide.
Fitting the CRC100R
The CRC100R is supplied on a mounting bracket for fixing into a suitable enclosure via
four fixing holes. Use 4 x M4 screws to secure the controller to a back plate.
Power & Cabling Requirements
Connect a suitable power supply and wire the CRC100R according to the diagram below.
Reader
Voltage Setting
(see note 1)
Supply
5 Volts
Voltage
Connect screen
to suitable ground
Typical Output Relay Wiring
(see note 2)
Maglock
Auxiliary Output (0v when active)
typically used for card capture
Notes
1. To avoid damage to the reader, ensure that the reader voltage-setting jumper on the rear of the
unit is set to the correct voltage for the reader before you apply power to the CRC100.
2. The example is based on a maglock using the normally closed (fail safe) contacts. Use the
appropriate contacts according to the application.
3.
With REX/Arming set to 'REX', the strike relay operates when '0 volts' and 'REX/Arming' are
short-circuited.
With REX/Arming set to 'ARM', Cards will not read while '0 volts' and 'REX/Arming' are short-
circuited.
CRC100R Quick Installation Guide
RELAY
1N4001
Diode
0V
+Ve
Low Voltage
DC Power Supply
Page 1
READER
N/O Push Button
ISSUE 03
+
PSU
9-24V DC
Request to Exit
or Arming
(see note 3)
Reader

Advertisement

loading

Summary of Contents for Nortech CRC100R

  • Page 1 CRC100R Controller. For detailed CRC100R user information, refer to the User Guide. Fitting the CRC100R The CRC100R is supplied on a mounting bracket for fixing into a suitable enclosure via four fixing holes. Use 4 x M4 screws to secure the controller to a back plate.
  • Page 2 CRC100R Quick Installation Guide ISSUE 03 Basic Confidence Check Once all cables have been terminated, power up the CRC100R and check that the opening screen is displayed as follows: C R C 1 0 0 R V e r : 2 . x x Also check that the connected reader has the correct ready status displayed (refer to the anufacturer’s handbook).
  • Page 3 See explanation below) below. Standard Nortech Clock & Data (Mag) Card Format Settings If the CRC100R is to be used with standard cards that have been supplied by Nortech, the card format settings should be: Format: MAG Digits: 10 Len: 8 Offset: 02 Note: No site code is necessary as all digits are used as the card number.
  • Page 4 CRC100R Quick Installation Guide ISSUE 03 Note 1: In W26 mode, there is a n option to set the site code and add the cards by card number only. If required , add the site code before continuing with the sequence.