Burst Level Adjustment (Vc-211 Board); G-Cam Flip Adjustment - Sony FCB-IX47 Service Manual

Color video camera
Hide thumbs Also See for FCB-IX47:
Table of Contents

Advertisement

3. BURST Level Adjustment (VC-211 board)

Set the chroma signal output level.
Subject
All black
Pin 6 of CN301
Measurement Point
Measuring Instrument Oscilloscope
Adjustment Page
F
Adjustment Address
4B
Specified Value
A = 286±5mV (NTSC)
A = 300±5mV (PAL)
Note: Terminate at 75Ω resistor and measure.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 4B, change the data and set the burst
level (A) to the specified value.
3) Press the PAUSE button of the adjusting remote commander.
4) Select page: 0, address: 01, and set data: 00.
H
FCB-IX47/47P
FCB-IX470/470P
http://getMANUAL.com

4. G-CAM flip Adjustment

Set the color reproduction conditions to optimum.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1. Displayed data of page 1 of the adjusting remote com-
mander.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 16.
3) Select page 1 of the adjusting remote commander, and compare
A
the higher 2 digits (S1) and lower 2 digits (S2) of the 4-degits
display data.
When S1<S2
Perform steps 5) onwards.
When S1 S2
Perform steps "Processing after Completing Adjustments".
4) Select page: F, address: 21, set data: 52, and press the PAUSE
button of the adjusting remote commander.
Before Modify data
5) Select page: 0, address: 03, and set data: 00.
6) Select page: 0, address: 01, and set data: 00.
Not required
Display data of page 1 of the adjusting
remote commander (Note 1)
F
21
S1 S2
1 : XX : XX
n S2
n S1
After Modified data
52
D2
D2
52
2-15 (E)