Charcoal filter
CLEANING THE GREASE FILTER
Filters are mounted with the use of clips and pins
on the opposite side.
To clean the filter:
1. Press the handle of the mounting clip on the
filter panel underneath the hood (1).
1
2
2. Slightly tilt the front of the filter downwards (2),
then pull.
Repeat the first two steps for all filters.
3. Clean the filters using a sponge with non
abrasive detergents or in a dishwasher.
The dishwasher must be set to a low
temperature and a short cycle. The
grease filter may discolour, it has no
influence on the performance of the
appliance.
4. To mount the filters back follow the first two
steps in reverse order.
Repeat the steps for all filters if applicable.
REPLACING THE CHARCOAL FILTER
WARNING! The charcoal filter is
NON-washable! The filter cannot be
regenerated!
To replace the charcoal filter:
1. Remove the grease filters from the appliance.
Refer to "Cleaning the grease filter" in this chapter.
2. Turn the filter counterclockwise (1) and then
pull (2).
The time of saturation of the charcoal filter varies depending on the type of cook-
ing and the regularity of cleaning the grease filter. The activated charcoal filter is
not washable, cannot be regenerated and must be replaced approximately every
4/6 months of operation, or more frequently for particularly heavy usage.
To mount the filters back follow the steps in reverse
order.
In any case, it is necessary to replace the filters at
least every four months.
REPLACING THE LAMP
WARNING! Risk of burns and electric
shock! Disconnect the appliance from
the electricity before the operation!
Make sure that the light bulb has
cooled down before touching it.
WARNING! Risk of injury! Use
protective gloves to replace the lamp.
Risk of damage to the appliance! Do
not use sharp edged tools!
Replace the burnt light bulb in accordance with the
specifications:
Power (W)
Socket
Voltage (V)
Dimensions (mm)
ILCOS D Code (ac-
cording IEC 61231)
To replace the lamp:
1. The lamp cover has two slots on each side.
Use a flat non sharp plastic tool. Gently remove
the lamp cover from the appliance.
2. Replace the lamp.
3. Mount the lamp cover.
1
2
4
E14
220 - 240
37 x 100 (diameter x
length)
DRBB/
F-4-220-240-
E14-37/100
9