COUNTER/TIMER CNT-700 MANUAL
Thank you for your purchase of our Counter/Timer CNT-700 series. Please read this manual carefully and
understand totally before use this device. This manual contains important information to use safely for this
product.
1)
Symbols and meaning
The following symbol is very important to use this device safely. Please be sure to handling to carefully this
manual of this symbol.
(Warning)
!
This devices dose not verify as safety devices, when you use together with dangerous devices, so please use
nd
after install 2
safety device before this devices.
(Danger)
①electric shock – Never touch the AC terminal with bare or wet hand during power on. It may cause electric
shock.
②Please make sure turn off power when you check power line .
(Caution)
!
1.
Please use over M 3.5, width max 7.2m terminal wire for AC power line.
2.
Do not use without manufacture recommended application, it may cause damage of body or broken
of product.
3.
Please prevent the dust, water, oil and debris of wire into the devices. It may cause the fire or
damage of products.
4.
Do not disassemble or convert or remodel without permission from manufacture. it may cause error
and cannot guarantee the quality.
5.
Please be sure making wire separately with power line to reduce inducts noise.
6. Please install the switch or circuit Breaker to protect from over voltage.
7. Please be sure make wire separately with signal line and power line to reduce induct noise
8. Please do not install the devices near high frequency noise generating devices (likes high frequency
welding M/C, high capacity SCR controller, Inverter, etc.)
The above mentioned note is can make error to devices.
Please be sure for follow as described at manual.

Advertisement

loading

Summary of Contents for Samwon ENG CNT-700

  • Page 1 COUNTER/TIMER CNT-700 MANUAL Thank you for your purchase of our Counter/Timer CNT-700 series. Please read this manual carefully and understand totally before use this device. This manual contains important information to use safely for this product. Symbols and meaning The following symbol is very important to use this device safely. Please be sure to handling to carefully this manual of this symbol.
  • Page 2: Specifications

    1.MODEL & SUFFIX CODE CNT – 700-2P : DISPLAY ONLY OUTPUT 1P : 1 LAYER DISPLAY 2P : 2 LAYER DISPLAY SIZE 700: 72(W) * 72(H 2.SPECIFICATIONS Counter measurement value display Measurement Display / Timer time progress value Parameter Setting value Counter setting values display Display / Timer setting values display...
  • Page 3: Part Name & Functions

    3. PART NAME & FUNCTIONS Counter Display 1Layer Setting/Lamp Setting Display 2 Layer Setting/Lamp Timer Operation Lamp 1.PS 2.PS Batch Setting Lamp Lamp LOCK OUT1 OUT2 Key Lock Lamp Counter Operation Lamp OUT1 output Lamp Increase Button Reset Button Batch Button Cursor Move Button Batch Output Lamp OUT2 output Lamp...
  • Page 4: Dimensions & Panel Cutout

    4. DIMENSIONS & PANEL CUTOUT <Panel Cutout Size > +0.6 Width: 68 +0.6 High: 68 5. TERMINAL WIREING DIAGRAM 1) CNT-700-1P 2) CNT-400-2P +12VDC BATCH +12VDC BATCH INB 100mA 0V RESET INHIBIT RESET INB 100mA 0V RESET INHIBIT RESET SSR 출력(30VDC 100mA)
  • Page 5 3) CNT-700-N +12VDC INB 100mA 0V RESET INHIBIT 17 18 AC IN AC IN 100~240VAC 50~60HZ * when select voltage input(PNP) , electric contact input connect INB +12VDC 0V RESET INHIBIT BATCH RESET * when select non voltage input(NPN) , electric contact input connect...
  • Page 6 Note) INA terminal “ count input” or “count stop input” signal input terminal •When use as a counter : •When use as a timer : “START”signal input terminal. Note) INB/INH terminal • When use with counter : INB become signal input terminal. •...
  • Page 7 2) INPUT: VOLTAGE INPUT(PNP) (1) NO ELECTRIC CONTACT INPUT Counter/Timer Counter/Timer Sensor Sensor ③ ③ +12V +12V ※ ※ Signal /Input 5.6KΩ 5.6KΩ ④ ④ 입력부 (PNP Voltage output (PNP Open collector Output) (2) ELECTRIC CONTACT INPUT (COUNTING SPEED SET WITHIN 1~ 30cps.) COUNTER/TIMER ③...
  • Page 8: Output Wiring Diagram

    7. OUTPUT WIRING DIAGRAM DRY CONTACTOUTPUT 2) OPEN COLLECTOR OUTPUT COUNTER/TIMER COUNTER/TIMER 카운터/타이머 Load Load Power (LOAD POWER) (DC) Load 3) Caution for the Non Contact(Dry Contact) output connection * Must Do not exceed Non Contact (Dry Contact) output capacity 30VDC 100mA. * Please connect the surge abserver ( Diode, Barrister) at the load both side when use induct load likes Relay 8.
  • Page 9 * After change of setting value to “0” if push key or input RESET during operate mode, output keep OFF status. (but when output mode ”T” status, if set 1layer setting value as “0”,then1 layer display output keep ON status). 3) TIMER PRE SETTED VALUES CHANGE 1) In case of the output mode is not FLK ▶...
  • Page 10 key, key, key cannot use “ lock” 5) Batch Setting Change ▶Push key one time during operate status mode. First number will blinking and become batch counter setting mode. ▶ Change setting values use ▶ After change with wanted setting value, move to setting mode push by key.
  • Page 11 Batch out is maintain regardless of the power ON/OFF. Batch Count Value’s dose not effected for key and external RESET input signal. 7) SCALE VALUES SETTING It is useful to change the input pulse value to real change scale values. Ex) Position control using by counter and encoder.
  • Page 12 Operation Mode (Counter) Push 3 second SET key INPUT MODE ( COUNT SPEED ( OUTPUT MODE ( OUT2 OUT TIME ( OUT1OUT TIME ( INPUT LOGIC ( MIN RESET TIME ( DECIMAL POINT ( SCALE SET ( COUNT MEMORY ( KEY LOCK ( COUNTER/TIMER SELECT ( 선택(...
  • Page 13 Input mode In case of output mode is S, T, D, input mode fixed to Ud-A, B, C. Max count Maxcount speed base on the INA or INB input signal is1:1 Speed Max count speed setting is applied same time at INA,INB. In case output mode is “D”...
  • Page 14 Voltage input(PNP) Dry contact input(NPN) 5-30VDC (Short) 0-2VDC (Open) 8) INPUT MODE OF OPERATION (COUNTER) Input mode Count diagram Remarks INA: count input INB: count input stop ( limitation of count of INA) In case of INA is “L”, count stop setting (INB:”L”->”H”)or unlock of count stop 계수금지...
  • Page 15 INA:PULS(Up)Count input INB:MINUS(Down)Count input (Up/ INA and INBis input from “L”to “H” simualtanously It sustain before count input status. Down- 계수값 개별입력 Incase of Encorder output A,B pole connect to couter input INA, INB, counter mode need set to (Ud-C) mode. (Up/ B B B B Down-C)
  • Page 16 RESET 999999 PRESET PRESET 9) OUTPUT MODE OF OPERATION (COUNTER) OUT2 (OUT ) RESET 999999 One-shot output(OUT1 output) One-shot output Accord output PRESET Self maintain output PRESET Self maintain output (OUT2 output) OUT2 (OUT Input mode Output Mode Explanations Up/Down – A, B, C Down After Count-up, Display Values increase or decrease according to input and the output...
  • Page 17 with OUT2 The Display values and the self sustain output of OUT1 will sustain after count up until RESET Reset input is initialized 999999 PRESET The One-shot output time of OUT1 is not PRESET connected with OUT2 다. 1 OUT2 (OUT Up/Down –...
  • Page 18 * IN CASE OF 2LAYER DISPLAY MODEL,DURING TIMER OPERATION MODE THE OUTPUT WILL LIMITED ONLY TO OUTPUT ,THE OUTPUT 1 ALWAYS MAINTAIN OFF STATUS. Change the setting values use by key. If push the key, the cursor move to next step one by one. OPERATION MODE (TIMER)) PUSH OVER 3 SECONDS SET TIME RANGE...
  • Page 19 12) OUTPUT OPERATION MODE(TIMER) * Power Reset : Do not compensate the display values when it power off .(In case of power off the display values initialized) * Power Hold : Compensate the display values when it power off .(Memorized the display values when it power off before. Restore POWER POWER Display memorized values before power off when recover to power on)
  • Page 20 2) In case of INA ON : Power ON Start POWE Reset OFF Start 3)Contorl output poerate One-shot . 4) In case of too small time setting, INHIBIT Contact out put make error of output by responds time RESE Please set minimum setting time is over 100ms or more OUT2(OUT 설정시간...
  • Page 21 13) ONLY DISPLAY MODE OPERATION 1) Counter(In case of Input mode is UP) 2) Counter(In case of Input mode is DOWN) RESET RESET INHIBIT INHIBIT 999999 999999 -999999 3) Counter(In case of the Input modeisUd-A), 4) Incase of timer individual input(Ud-B), or (Ud-C)) POWER RESET INHIBIT...