Pacific Ventilation BEC 150HP User Manual

Centrifugal ceiling extract fan

Advertisement

Quick Links

User's Manual
BEC 150HP – Centrifugal ceiling extract fan
www.pacificventilation.com

Advertisement

Table of Contents
loading

Summary of Contents for Pacific Ventilation BEC 150HP

  • Page 1 User’s Manual BEC 150HP – Centrifugal ceiling extract fan www.pacificventilation.com...
  • Page 2: Table Of Contents

    Contents Safety requirements ... Purpose . Delivery set... Designation key ... Technical data ... Design and functioning Mounting and set-up... Connection to power mains ... 10 Electronics operation algorithm ... 10 Technical maintenance ... 11 Manufacturer’s warranty ..12 This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
  • Page 3: Safety Requirements

    Safety requirements All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical,  and technical norms and standards must be observed when installing and operating the unit. Disconnect the unit from the power supply prior to any connection, servicing, maintenance, and repair operations. Only qualified electricians with a work permit for electrical units up to 1000V are allowed for installation and maintenance. The present user’s manual should be carefully read before beginning works.   Check the unit for any visible damage of the impeller, the casing, and the grille before starting installation. The  casing internals must be free of any foreign objects that can damage the impeller blades.   While mounting the unit, avoid compression of the casing! Deformation of the casing may result in motor jam and  excessive noise.
  • Page 4 The connection to the supply mains must be made through a means of disconnection, which is incorporated in the  fixed wiring in accordance with the wiring rules, and has a contact separation in all poles that allows for full  disconnection under over voltage category III conditions. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons  in order to avoid a safety hazard. CAUTION: In order to avoid a safety hazard due to inadvertent resetting of the thermal cut-out, this appliance must  not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly  switched on and off by the utility. Ensure that the appliance is switched off from the supply mains before removing the guard.  WARNING: If unusual oscillating movements is observed, immediately stop using the appliance and contact the  manufacturer, its service agent or suitably qualified persons. The replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service  agent or suitably qualified persons. Fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to  withstand 4 times the weight of the appliance. The mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably  qualified persons. The appliance is to be installed so that the blades are more than 2.3m above the floor. Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or  other fuel-burning appliances. The product must be disposed separately at the end of its service life. Do not dispose the unit as unsorted domestic waste.  ...
  • Page 5: Purpose

    The choice of unit installation location must prevent unauthorised Access by unattended children. The unit must not be operated in kitchen premises. Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances,  fibrous materials, coarse dust, soot and oil particles or environments favourable for the formation of hazardous  substances (toxic substances, dust, pathogenic germs). Delivery set Name BEC 150HP Round Centrifugal ceiling extract fan 1 pc. Decorative grille  1 pc. User’s manual 1 pc. Packing box 1 pc.
  • Page 6: Technical Data

    Technical data The centrifugal ceiling extract fan  is designed for indoor application with the ambient temperature ranging  from +1 °C up to +45 °C. The unit is rated as a Class I electrical appliance. The unit design is constantly being improved, thus some models may be slightly different from those described  in this manual. Overall and connecting dimensions BEC 150HP BEC 150HP Round Template for marking the fan installation location   Pacific Ventilation ...
  • Page 7: Design And Functioning

    Technical data Parameter BEC 150HP Frequency [Hz] Voltage [V]  1 ~ 220-240 Rated fan power [W] RPM [min ]  1085 Current [A] 0.25 Max. air flow [m Max. air flow [l/s] Specific fan power (SFP) [W/l/s] 0.43 Sound pressure level at 3m distance [dBA] Weight [kg]  4.13 IP  SEC class Design and functioning Terminal box Decorative panel Exhaust air duct with a non- return valve Casing The fan casing is made of plastic.
  • Page 8: Mounting And Set-Up

    Mounting and set-up Read the user’s manual before installing the unit. The fan is a component part and is not designed for stand-alone operation. The fan is designed for ceiling mounting and installation in the floor slab with fastening to the ceiling surface using  removable rotary clamping brackets on the fan casing. The fan installation location must comply with local building codes for this type of product. Check the fan for mechanical damages prior to mounting. Before mounting make sure the casing does not contain any foreign objects (e.g. foil, paper). While installing the unit ensure convenient access for subsequent maintenance and repair. The minimum distance between the fan and the ceiling should be at least 5 mm. L = 5mm (min)   Pacific Ventilation ...
  • Page 9 Mounting sequence 1. Use the template to mark the  2. The flexible air duct is pushed  3. Before installation, it is required to  mounting location for the fan and  through the hole from behind the  loosen the self-tapping screws on  make a hole in the ceiling Ø 300 mm. ceiling, from above. The air duct is  the rocking levers, thereby increasing  installed on a spigot with a non- the gap between the casing and the  return valve. lever. 4. The spigot and the air duct are  5. The fan assembly is inserted into the  6. Secure the fan by turning the levers. installed on the fan. ceiling opening from the room side. 7. After installing the fan, it is necessary  8. Install the decorative panel (purchased separately for the BEC 150HP model)  to clamp the self-tapping screws on  on the fan casing. The panel is mounted in accordance with the User’s manual  the rocking levers to press the fan  for the decorative panel. casing against the ceiling.  Pacific Ventilation ...
  • Page 10: Connection To Power Mains

    Connection to power mains Power off the power supply prior to any operations with the unit. The unit must be connected to power supply by a qualified electrician. The rated electrical parameters of the unit are given on the Manufacturer’s label. Any tampering with the internal connections is prohibited and will void the warranty The fan is rated for connection to single-phase AC 220-240 V/50 (60) Hz.
  • Page 11: Technical Maintenance

    Technical maintenance Disconnect the unit from power supply before any maintenance operations! Ensure that the unit is switched off from the supply mains before removing the guard. The fan maintenance includes regular cleaning of the surfaces of dust and dirt. Replace the filter as required, but at least  every 6 months. The impeller cleaning is shown below. Clean the impeller blades thoroughly every 6 months. Troubles and troubleshooting Trouble Possible reasons Troubleshooting Check the electric connections and the  No power supply. operation status of the circuit breaker. The fan does not get started.
  • Page 12: Manufacturer's Warranty

    Manufacturer’s warranty Pacific Ventilation warrants that all goods manufactured or supplied will be free of defects in workmanship and materials  for a period of 12 months from the date of invoice to the customer, provided that the goods are installed according to the  requirements of AS/NZS3000:2007 Australian / New Zealand wiring rules and the installation instructions described herein.  Pacific Ventilation accepts no responsibility for costs involved in the removal or replacement of defective parts.  Pacific Ventilation may require the return of goods at the claimants expense to establish the validity of the claim.  A full copy of our conditions of sale including warranty provisions is available at www.pacificventilation.com. Note: with the purpose of performing warranty servicing you please produce User Manual or other relevant substituting  document and the payment document as an evidence of the purchase with indication of the sale date.  The product model shall comply with that one specified in the User Manual or other relevant substituting document.  The warranty repair does not include:   routine technical maintenance   unit installation/dismantling   unit setup To benefit from warranty repair, the user must provide the unit, the user’s manual with the purchase date stamp, and  the payment paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual.  Contact the Seller for warranty service.   Pacific Ventilation ...
  • Page 13 The manufacturer’s warranty does not apply to the following cases:   User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission  with missing component parts previously dismounted by the user.   Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user’s  manual.   User’s failure to ensure timely technical maintenance of the unit.   External damage to the unit casing (excluding external modifications as required for installation) and internal  components caused by the user.   Redesign or engineering changes to the unit.   Replacement and use of any assemblies, parts and components not approved by the manufacturer.   Unit misuse.   Violation of the unit installation regulations by the user.   Violation of the unit control regulations by the user.   Unit connection to power mains with a voltage different from the one stated in the user’s manual.   Unit breakdown due to voltage surges in power mains.   Discretionary repair of the unit by the user.   Unit repair by any persons without the manufacturer’s authorization.   Expiration of the unit warranty period.  ...
  • Page 14 Notes   Pacific Ventilation ...
  • Page 15 Notes  Pacific Ventilation ...
  • Page 16 We are the safe choice. Pacific Ventilation Pty Ltd AU 1300 733 833 NZ 0800 100 326 www.pacificventilation.com...