Advertisement

Quick Links

Operation manual
SIP Monitor Beward
SM700 and SM700W
Beward.
RU
1
SM700 (W) Monitor SIP Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Beward SM700

  • Page 1 Operation manual SIP Monitor Beward SM700 and SM700W Beward. SM700 (W) Monitor SIP Operation Manual...
  • Page 2: Table Of Contents

    Directory Directory ....................................2 Chapter 1 Preventive measures ............................3 Chapter 2 General situation .............................. 5 2.1.......................6 SIP Features of Beward SM700 (W) Monitor ............................... 6 2.2.Main features ..............................7 2.3.Complete supply ..........................7 2.4.Minimum system requirements Chapter III Basic elements of equipment ........................8 Chapter IV Local interface ...............................10...
  • Page 3: Chapter 1 Preventive Measures

    Please contact the service center of "Beyward" Natural Gas Production Enterprise Co., Ltd.. You can find the contact information on the website Http://www.beward.ru/ Transport When transporting, place the SIP monitor in the manufacturer's packaging or any other material of appropriate quality and impact resistance. SM700 (W) Monitor SIP Operation Manual...
  • Page 4 Wipe the outer surface with a soft dry cloth. For stains that are difficult to remove, use a small amount of detergent and then dry the surface. Do not use alcohols, acetones, acids and gasoline as they can damage the monitor's SIP housing. SM700 (W) Monitor SIP Operation Manual...
  • Page 5: Chapter 2 General Situation

    Function keys. The monitor looks like Figure 2.1. Figure 1. 2.1 Beyward SM700 (W) is easy to operate and convenient to use. It can receive SIP calls, conduct full-duplex real-time conversations, and watch video from an IP camera connected to it by pressing a hotkey.
  • Page 6: Sip Features Of Beward Sm700 (W) Monitor

    Make SIP application of SM700 (W) monitor universal in both private sector and corporate sector. There are two options for connecting Beward Monitor's SIP to Ethernet: For SM700 models, use 10BASE-T/100BASE-TX wired interface For SM700W, use 10BASE-T/100BASE-TX wired interface and IEEE 802.11 BGN built-in WiFi module (2.4 GHz)
  • Page 7: Complete Supply

    Adapter for power supply with DC plug 2.1 LIQUID 5.5 (optional) Attention! Beward reserves the right to change the device configuration and any features without prior notice. 2.4.Minimum system requirements Before using the 7 "SIP monitor, make sure your computer meets the minimum requirements (or higher).
  • Page 8: Chapter Iii Basic Elements Of Equipment

    Chapter III Basic elements of equipment The main SIP components of the SM700 (W) monitor are shown below (Figures 3.2 and 3.2). 3.3). Figure 1. 3.1 Figure 1. 3.2 Display (1): 7-inch TFT LCD displays the monitor's SIP menu and video streams from the call panel and IP camera.
  • Page 9 Power and network connectors (6) are used to connect to the LAN and provide 12V, 1A (maximum) DC power on the SIP monitor. The external USB memory connector (7) is used for connecting the external USB memory to the SIP monitor. SM700 (W) Monitor SIP Operation Manual...
  • Page 10: Chapter Iv Local Interface

    To enter the main menu, you can press the [gear] touch button while sleeping. The main device menu includes the following: Call Record: Allow you to view the log of unconnected, answered and rejected calls, the start time of calls and the log of open door records. SM700 (W) Monitor SIP Operation Manual...
  • Page 11: Video On Demand Display

    If the IP camera is not connected to the SIP monitor of the selected channel, switching to this menu will display the "No Video Signal" text. For actions in the VOD menu, the following touch buttons are available: [Exit]: Exit the VOD menu. SM700 (W) Monitor SIP Operation Manual...
  • Page 12: Call Menu

    To operate in the Invoke menu, touch the following touch buttons: Cross in the Circle: Complete the challenge. [Key]: Open the door. [Receiver]: Begin the conversation. 4.3.Session menu Below is the session menu (Figure 1). 4.4). SM700 (W) Monitor SIP Operation Manual...
  • Page 13: Menu Call Log

    To operate on the Session menu, you must touch the following touch buttons: Cross in the Circle: End of conversation. [Key]: Open the door. 4.4 Menu Call Log The following is the call log menu (Figure 1). 4.5). SM700 (W) Monitor SIP Operation Manual...
  • Page 14 [Page number]: Sequence number of the call log. Arrow [left]: The arrow that moves to the previous page of the call log. Arrow [right]: The arrow that goes to the next page of the call log. SM700 (W) Monitor SIP Operation Manual...
  • Page 15: Detailed Photo View Menu

    The menu is designed to view the photos of the caller in detail. Detailed photo view menu item: [Event number]: Sequence number recorded in call log. [Cancel (A)]: Exits the Detailed Photo View menu. Arrow [left]: The arrow pointing to the previous photo in the call log. SM700 (W) Monitor SIP Operation Manual...
  • Page 16: Turn On And Off Of Mute Mode

    In addition, you can set the automatic turn-on and turn-off of daytime mute mode through the Web interface see Section 9.(See page 1 of this document). 4.6.Configuration menu Here is the setup menu (Figure 1). 4.8). SM700 (W) Monitor SIP Operation Manual...
  • Page 17: Sound Menu

    [OK]: Enter the selected menu. [Cancel]: Return to the main menu. [Left]: The navigation box moves to the left. [Right]: The navigation box moves to the right. Sound menu Below is the Sound Setup menu (Figure 1). 4.9). SM700 (W) Monitor SIP Operation Manual...
  • Page 18 To navigate and operate in the Sound Settings menu, touch the touch buttons below the Exit, Left, Right arrows, plus and minus icons: [Exit (O)]: Return to the Settings menu. [Left]: The navigation box moves up. [Right]: The navigation box moves down. SM700 (W) Monitor SIP Operation Manual...
  • Page 19: Menu Maintenance

    Restart the operating system: Restart the monitor's SIP operating system. [Reset to factory settings]-Resets the monitor SIP settings set by the user to factory settings. The entries in the call log remain unchanged when the settings are reset. SM700 (W) Monitor SIP Operation Manual...
  • Page 20: Ktotam Menu

    [Cancel]: Return to the Settings menu. [Left]: Move the top of the navigation box. [Right]: Move the navigation box down. KTOTAM menu Below is the KTOTAM Cloud Service Connection Activation menu (Figure 1). 4.11). Figure 1. 4.11 SM700 (W) Monitor SIP Operation Manual...
  • Page 21 Beward SM700 (W) SIP Monitor via the KTOTAM Cloud SIP Server without any setup (plug and play) on the SM700 (W) SIP Monitor. The SM700 (W) can only be registered on KTOTAM via the KTOTAM Android or iOS app by scanning the QR code on the monitor screen. To run in a cloud service, the monitor must be connected to a network with an Internet connection.
  • Page 22 Disconnect from the KTOTAM server button is displayed instead of the Enable Connection to the KTOTAM server button (Figure 1). 4.13).If you successfully connect to the server, the connection status will be displayed as "Online" and the connection duration will be displayed. SM700 (W) Monitor SIP Operation Manual...
  • Page 23 Figure 1. 4.13 SM700 (W) Monitor SIP Operation Manual...
  • Page 24: Chapter V Wired Connection Settings

    Chapter V Wired connection settings 5.1.Determine the IP address of the SIP monitor The SIP Beward Monitor SM700 (W) with default settings uses DHCP functionality, which allows connections to devices on the network without manually supplying IP addresses to the devices.
  • Page 25 In this regard, to save the settings, you must power off the monitor for at least 60 seconds after saving the latest changes to the Web interface. SM700 (W) Monitor SIP Operation Manual...
  • Page 26: Chapter 6 Set Up A Wireless (Wi-Fi) Connection

    Chapter 6 Set up a wireless (Wi-Fi) connection 6.1.Wireless SIP Monitor SM700W Connection Overview You can connect the Beward SM700W SIP Monitor to a wireless network in one of two ways: 1) Use WPS. 2) Connect by configuring the Web interface.
  • Page 27: Setting Up A Wireless Sip Monitor Connection Through A Web Interface

    6.3.Configuring SIP Monitor Wireless Connection through Web Interface Access the Beward SM700W SIP Monitor using a wired connection, as described in the section Page 5 of this document. After successful authorization, you will access the SIP Web interface of the monitor (Figure 6.2).
  • Page 28 You can display the characters to check by clicking the Eyes icon to the right of this field. Click the Save button at the bottom of the window to save all changes and connect to a Wi-Fi hotspot. SM700 (W) Monitor SIP Operation Manual...
  • Page 29 If necessary, by analogy, fill in the Preferred DNS, Alternative DNS fields. If all the settings are correct, you can access SIP Monitor through a wireless connection. Attention! Before using a wireless connection, disconnect SIP Monitor from the wired network, and then restart SIP Monitor. SM700 (W) Monitor SIP Operation Manual...
  • Page 30: Chapter Vii Network Interface: Settings-Audio

    [Speak Volume] (Default: 6): Allows you to adjust the volume. Available values: 1 to 7. [Microphone Volume] (Default: 50): Allows you to control the loudspeaker volume by configuring the built-in audio codec. Available values are 1 to 100. To save your changes, click the Save button. SM700 (W) Monitor SIP Operation Manual...
  • Page 31: Chapter Viii Web Interface: Settings-Network

    [External IP Address]: Sets the monitor's external IP address SIP value to access the device from the Internet. [HTTP]: Sets the HTTP port value for the monitor IP address SIP to access the device from the Internet. To save your changes, click the Save button. SM700 (W) Monitor SIP Operation Manual...
  • Page 32: Lan

    [IP Address]: Sets or displays the IP address of the device (when DHCP is enabled). Attention! When assigning SIP to the IP Address Monitor, consider that IP addresses should not be duplicated in the network. Subnet mask: Installs or displays the device's subnet mask (with DHCP enabled). SM700 (W) Monitor SIP Operation Manual...
  • Page 33: Wi-Fi (Sm700W Monitor Sip Only)

    [MAC Address]: Displays the MAC address of the SIP monitor. To save your changes, click the Save button. 8.3.Wi-Fi (SM700W Monitor SIP only) The Wi-Fi Connection Parameters page is shown in Figure 8.3. Figure 1. 8.3 SM700 (W) Monitor SIP Operation Manual...
  • Page 34 Password: Enter the password field for the selected access point. By default, the characters you enter are hidden. You can display the characters to check by clicking the Eyes icon to the right of this field. SM700 (W) Monitor SIP Operation Manual...
  • Page 35: Pppoe

    Status box, and the font of the connected access point in the list will become bold. Attention! Before using a wireless connection, disconnect SIP Monitor from the wired network, and then restart SIP Monitor. 8.4.PPPOE The pppoe parameter configuration page is provided in Figure 8.4. SM700 (W) Monitor SIP Operation Manual...
  • Page 36: Upnp

    Displays the connection time. To save your changes, click the Save button. 8.5.UPNP The UPNP parameter configuration page is provided in Figure 8.5. Figure 1. 8.5 [Enable upnp] (Default: Enabled): Enable\ Disable network connections UPNP equipment detection SM700 (W) Monitor SIP Operation Manual...
  • Page 37: Bonjour

    [Device Name]: Enter the name of the device to display when the device is online. To save your changes, click the Save button. Press the Default button to return to the original option. 8.7.DDNS The DDNS parameter configuration page is provided in Figure 8.7. SM700 (W) Monitor SIP Operation Manual...
  • Page 38 [Domain Name]: Enter the domain name obtained when you register your account on the DDNS provider's website. [Server Address]: Enter the address of the DDNS service provider. If the required DDNS provider is not in the list of DDNS servers, you can enter the server address manually. SM700 (W) Monitor SIP Operation Manual...
  • Page 39: Pptp

    Enter the IP address or domain name of the PPTP server to use. [User]: Enter the user name to access the PPTP server. [Password]: Enter the password to access the PPTP server. [IP Address]: Display of the IP address obtained after establishing the PPTP connection. SM700 (W) Monitor SIP Operation Manual...
  • Page 40: Rtsp

    G.711 audio. Attention! You must specify authorization in the row with RTSP link.Examples of RTSP links for Beward B, DS, and DKS family devices: RTSP://< login >: < password > @ < ip >: < port >/av < x > _ < y >, where: <...
  • Page 41: Https

    Self-signed certificate: Create a self-signed certificate. After you enter all the necessary information in the pop-up window and click the Create button, the certificate will be immediately available and displayed in the Installed Certificates box. SM700 (W) Monitor SIP Operation Manual...
  • Page 42: Ktotam

    When accessing the Web interface using HTTPS, port 443 is used. Consider this if you are using port reassignment on your router. To save your changes, click the Save button. .11.8 KTOTAM The KTOTAM cloud service connection activation page in Figure 8.11. SM700 (W) Monitor SIP Operation Manual...
  • Page 43: Sip

    The SIP Monitor allows calls to be received through the SIP protocol and P2P methods or through a SIP server. This device allows up to 2 different SIP accounts. The SIP parameter configuration page is provided in Figure 8.12. SM700 (W) Monitor SIP Operation Manual...
  • Page 44 Password: Enter the account password to authorize the device on the SIP server. [SIP Port] (Default: 5060): Sets the port value to communicate with the SIP server. [Allow check-in] (Default: off): This option allows check-in to the SIP server. SM700 (W) Monitor SIP Operation Manual...
  • Page 45 [Use Gate 2] (Default: No). Activate the display of door open button 2 in call and talk mode. [DTMF for Gate 2] (Default: 2). Door opening DTMF code setting 2. When you press the [key] button on the SIP monitor, you can do the following for the device in talk mode SM700 (W) Monitor SIP Operation Manual...
  • Page 46 [Dial timeout] (default: 120 seconds). Set the maximum wait time for answering calls. [Conversation Timeout] (Default: 360 seconds). Set the maximum talk time. An example of populating settings when connecting to the public server sip.antisip.com is shown in Figure 8.13: SM700 (W) Monitor SIP Operation Manual...
  • Page 47 Figure 1. 8.13 An example of populating settings when using SIP P2P is shown in Figure 8.14: SM700 (W) Monitor SIP Operation Manual...
  • Page 48 Figure 1. 8.14 To save your changes, click the Save button. SM700 (W) Monitor SIP Operation Manual...
  • Page 49: Chapter 9 Network Interface: Settings-Monitor

    [Mute Mode Open Time] (Default: 0 hours and 0 minutes): Sets the daily mute mode open time. [Mute off time] (default: 0 hours 0 minutes): Set the daily mute off time. To save your changes, click the Save button. SM700 (W) Monitor SIP Operation Manual...
  • Page 50: Chapter 10. Web Interface: Settings-System

    [Build Date]: Displays the build date of the current version of SIP Monitor firmware. [Web Interface Version]: Displays the current version of the Web interface. To save your changes, click the Save button. 10.2.Date and time The Date and Time page is shown in Figure 9.2. SM700 (W) Monitor SIP Operation Manual...
  • Page 51 Synchronize with Computer: Select this option to set the date and time for accessing the device based on PC data. [Manually Set Date (T)/Time (T)]: Select this option to set the date and time by entering a value in the Date/Time box. SM700 (W) Monitor SIP Operation Manual...
  • Page 52: Users

    User names and passwords are case sensitive and can contain 1 to 15 characters and include Latin letters (A-Z, A-Z), numbers 0 to 9, and periods (.). 10.4. Updates The Update page is provided in Figure 9.4. SM700 (W) Monitor SIP Operation Manual...
  • Page 53: Reset Settings

    The manufacturer is not responsible for the equipment failure caused by improper operation of software and hardware upgrade! 10.5.Reset Settings The Reset Settings page is provided in Figure 9.5. SM700 (W) Monitor SIP Operation Manual...
  • Page 54: Reload

    Save Network Settings option here so that the settings in the Network menu will not be changed when you reset. After the factory SIP installation is resumed, the monitor will automatically restart. 10.6. Reloading The Restart page is provided in Figure 9.6. SM700 (W) Monitor SIP Operation Manual...
  • Page 55 [Restart]: Clicking this button will restart the SIP Monitor. The restart process may take 1-2 minutes. After clicking the Restart button, a dialog box will be displayed to confirm the operation. Enter the administrator password and press OK to confirm, or press X to cancel. SM700 (W) Monitor SIP Operation Manual...
  • Page 56: Annex

    Here are some values for factory installation. Name Meaning DHCP Include 192.168.0.99 IP Address (Zeroconf) Subnet mask (Zeroconf) 255.255.255.0 Gateway (Zeroconf) 192.168.0.1 User name Admin Password Admin HTTP Port NTP Server Time. Nist.gov Time.windows.com Time-nw.nist.gov Time-A. Nist.gov Time-b.nist.gov SM700 (W) Monitor SIP Operation Manual...
  • Page 57: See Annex B. Guarantee Liability

    B6. Temperature and humidity Maximum and minimum operating and storage temperature and humidity values can be viewed in the technical specifications for specific equipment. SM700 (W) Monitor SIP Operation Manual...
  • Page 58 The connection of equipment should be carried out strictly according to the purpose and type of interface. B10. Guarantee liability NPP "Beward" LLC does not guarantee that the equipment will work properly in various configurations and applications, nor that the equipment will work according to customer expectations in specific uses.
  • Page 59 (e) Mechanical, thermal, chemical and other forms of effects, if the parameters of these effects exceed the permissible performance parameters, or if the technical specifications of the equipment are not provided for; G) High voltage effects (lightning, static electricity, etc.). SM700 (W) Monitor SIP Operation Manual...
  • Page 60: See Annex C. Rights And Support

    Any part of the information in the Operating Manual will be amended and supplemented by the Beward LLC without prior notice. For any errors that may occur in this manual, "New Beverard LLC assumes no liability whatsoever." Beward NPP LLC assumes no responsibility or warranty to issue updates or to maintain any information in this Operation Manual and reserves the right to modify this Manual and/or the products described therein at any time without prior notice.
  • Page 61 The actions you take to solve the problem for yourself (step by step). Set screenshots and connection options. The more comprehensive the information you provide, the faster our experts will be Can help you solve your problem. SM700 (W) Monitor SIP Operation Manual...
  • Page 62: Annex D. Vocabulary

    HTTP protocol is the highest layer protocol in TCP/IP protocol family. In a given protocol, any data packet is sent before receiving an acknowledgement of correct reception. SM700 (W) Monitor SIP Operation Manual...
  • Page 63 Internet session including multimedia content exchange. Used for IP telephony communication, video and audio conferencing. SIP Monitor-User equipment that uses SIP 2.0 technology to receive interphone calls over Ethernet. This paper introduces the model of Beward SM700 (W) device. SM700 (W) Monitor SIP Operation Manual...
  • Page 64 Certification. One way to authenticate on a computer system is to enter your user ID, popularly known as "login", and password, which are sensitive information, and knowing this information can ensure your ownership of certain information. SM700 (W) Monitor SIP Operation Manual...
  • Page 65 Full duplex is the simultaneous transmission of data in two directions. In a sound playback system, this can be described by, for example, a telephone system. Similarly, half-duplex communication provides two-way communication, but only in one direction at a time. SM700 (W) Monitor SIP Operation Manual...
  • Page 66 SM700 (W) Monitor SIP Operation Manual...

This manual is also suitable for:

Sm700w

Table of Contents