20-APR-2004 C L Marketing Inc. 2770 - 24 Avenue N.E. Calgary, Alberta T1Y 6V7 REGISTRATION NO. 26631 PEST CONTROL PRODUCTS ACT FOXXX GALAXY 2000 MODEL FXG5 Maximum output of Sodium Hypochlorite equivalent to 0.22 kg of chlorine per day WARNING: Operating the FOXXX GALAXY 2000 MODEL FXG5 without water flow through the cell can cause a build up of flammable gases which can result in...
Page 2
20-APR-2004 Soft Water Purification System DOMESTIC Installation / Operation Manual MODEL FXG5 REGISTRATION NUMBER 26631 PEST CONTROL PRODUCTS ACT PLEASE RETAIN OWNER'S MANUAL FOR FUTURE REFERENCE IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING & OPERATING C L Marketing Inc., 2770 - 24 Ave. N.E. Calgary, Ab. T1Y 6V7...
TABLE OF CONTENTS Model: FXG5 Important Safety Instructions i,ii Health, General & Hyperthermia Specifications Section 1 Water Pretest & Preparation System Sizing Pool Water Preparation & Monitoring Section 2 Plumbing Requirements Material Requirements for Installation Cell Installation & Pool Diagrams 8, 9 Section 3 Control Panel Mounting &...
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS EQUIPMENT RELATED, INSTALLATION AND GENERAL USE Installation of all GALAXY 2000 models When installing and using the GALAXY 2000 unit, basic safety precautions must always be followed, including the following: 1. Follow all aspects of the local and National Electrical Code(s) when installing the GALAXY 2000 unit.
Page 5
IMPORTANT SAFETY INSTRUCTIONS 110V Models Only (cord and plug) 1. WARNING - Risk of Electric Shock. Connect only to a grounding type receptacle protected by a ground-fault - circuit - interrupter (GFCI). Contact a qualified electrician if you cannot veri- fy that the receptacle is protected by a GFCI.
HEALTH, GENERAL & HYPERTHERMIA HEALTH, GENERAL AND HYPERTHERMIA General: WARNINGS - To reduce the risk of injury: 1. People using medications and/or having an adverse medical history should consult a physician before using a spa, hot tub or pool. 2. People with infectious diseases should not use a spa, hot tub or pool. 3.
Specifications Specifications ALL MODELS INPUT: 105 – 125 VAC, 50/60 HZ, 1.0 Amp for Model FXG5-1 210 – 250 VAC, 50/60 HZ, 0.5 Amps for Model FXG5- 2 Outputs Model FXG5 Cell Maximum output of Sodium Hypochlorite equivalent to 0.22 kg. of chlorine @3.0 Amps per 24 hours @max.
Section 1 a System Sizing for Swimming Pools System Sizing Use these three formulas to calculate the volume of water in the pool/spa: Rectangular Pool: Length(M) x Width(M) x Average Depth(M) x 1000 = Total Litres Oval / Round Pool: Diameter (M) x Diameter (M) x Average Depth (M) x 790 = Total Litres Free Form Pool: Average Length (M) x Average Width (M) x Average Depth (M) x 1000 = Total Litres...
Page 9
Section 1 a System Sizing for Swimming Pools (Continued) 2. Purifier Production/ System Sizing/ "Rules of Thumb" While purifier demand varies beyond precise prediction, and you may desire a higher or lower purifier resid ual in your pool, the following "rules of thumb" will assist you when choosing the GALAXY 2000 model.
Section 1 b Pool Water Preparation & Monitoring STEP 1 - Proper Water Balance Requirements: Proper GALAXY 2000 System operation is dependent on proper pool water conditions. Manually balance the pool water chemistry to meet all suggested ranges of water balance factors listed below before start - up of the GALAXY 2000 unit.
Page 11
Section 1 b Salt Requirements Needed for 3000 PPM KILOGRAMS OF SALT NEEDED FOR 3000 PPM RESIDUAL Salt Level Pool / Spa Volume in 1000’s of Litres Before Addition p p m 320 ppm 640 ppm 960 ppm 1280 ppm 1600 ppm 1 920 ppm 2240 ppm...
Section 2 a Material Requirements for Installation NEEDED BY INSTALLER SUPPLIED WITH GALAXY 2000 UNIT Required amount of salt 1) Residential Installation /Operation Hacksaw, Pipe Cutters or Cable Saw Manual Limited Warranty with Warranty Tape measure & Permanent Marker Card (Must Return) Screwdrivers: Flat head &...
Section 2 b Control Panel & Cell Installation Control Panel Using the supplied anchors and screws, the Control Panel s hould be mounted on a flat, sturdy, vertical sur face away from direct exposure to sunlight. The Control Panel is equipped with a 3.65 m DC cell cord and flow detector cord.
Page 14
Section 2 b In-Line Cell Installation Locations NOTE: See diagrams below for the proper location of the flow detector and cell, so not to over chlorinate/brominate the spa. Pool/Spa Flow Three Way Pump (Motorized) Valve Install Flow Detector(s) & Cell Here SPILLWAY Single Pump Pool /Spa Combination NOTE: If this scheme is desired and the spa is raised, a Swing Check Valve must be installed after the...
Section 3 a Control Panel Wiring 220V MODELS ONLY (You cannot switch to 110 volt power) STEP 1 - Wir ing All electrical equipment must be located 1.50 m or more from closest pool or spa waterline. Use the green and yellow stranded wire for Control Panel grounding. Attach a #8 or #6 solid bond wire to the bonding lug on the underside of the unit.
Section 3 b Electronic Component Location Model FXG5 a) ORP Controller - Install part # 993 per the instructions provided. NOTE: This is a dry contact input, DO NOT ENERGIZE THIS INPUT! DAMAGE TO THE CONTROL PANEL WILL OCCUR AND THE WARRANTY WILL BE VOIDED. When an ORP controller is interfaced to the GALAXY 2000 unit, your Output Control Dial should be set on 100%.
GALAXY 2000 Control Panel Functions Section 4 a Indicator Lights A. WHEN POWER IS FIRST TURNED ON: The lights will flash alternately for one minute while the GALAXY 2000 unit self-tests and awaits continuous flow. B. OK: If your GALAXY 2000 unit is wired properly, this indicator will display GREEN whenever the main filter pump is operating.
GALAXY 2000 Control Panel Functions (Cont’d) Once a bromine pool -Always a bromine pool. Use Of Sodium Bromide SODIUM BROMIDE (OPTIONAL) - 100 PPM Where Cyanuric acid is not available or where its use is restricted, bromine can be used as an alternative purifier to chlorine.
Section 4 c Section 4 c Optional Items & Replacement Parts PART DESCRIPTION NUMBER FXG5-1 Control Panel – 110V w / FXG5 Cell. Includes 91.5 cm (3’) power cord w /plug & socket for pool pump plug in. FXG5 – 2 Control Panel –...
PROBLEM CAUSE SOLUTION___________________________ 1. Insufficient purifier production. A. The test kit reagents or test strips are old or expired. A. Retest with new reagents or test strips. B. The unit is set too low in relation to an increased purifier demand B.
Page 21
PROBLEM CAUSE SOLUTION___________________________ 7. Single CHECK SYSTEM Flash A. Water exiting the filter is being diverted away from the inlet of the flow detector A. Increase the flow rate above 15 gallons (56 LPM) per minute to activate the flow detector. B.
SUMMARY OF GALAXY 2000 UNIT OPERATING MODES LOW FLOW/ORP (Blue) CELL MAIN FLOW (White) GALAXY 2000 UNIT PRINTED CIRCUIT B O T T O M PANEL OF THE GALAXY 2000 UNIT B O A R D MODE FUNCTION LO FLOW /ORP FLOW In - line operation Not connected...
Page 23
Above Ground Pool Installation Locations Appendix Appendix CONFIGURATION 1: Typical End- of- line Cell Installation (With Flow Switch) Install per diagram below. GALAXY 2000 Ground Mounting Kit consists of: (2) 91.5 cm - 1.9cm x 1.9cm x .3cm (3' - 3/4" x 3/4" x 1/8") aluminum angles with four predrilled 0.156 holes (4) #10-32 .9 cm (3/8") S.S.
Page 24
CONFIGURATION 2: Typical End- of- line Convection Installation (Flow Switch Disabled) For 24 Hour Operation As A "Convection Style" Unit OXYGEN BUBBLES GENERATED WITHIN THE CELL CAN BE UTILIZED TO CREATE FLOW. STEP 1 Disconnect the cell flow switch cable mounted with the cell. Plug the shorting plug (included in the convection installation kit) into the back 2-circuit connector input (plug closest to wall at bottom of Control Panel).
To obtain service for your GALAXY 2000 system, contact the Dealer/Service Centre listed below, or: Lectranator Systems, Inc. 2770 - 24 Avenue N.E. Calgary, Alberta, Canada T1Y 6V7 (403) 250-2494 If warranty service is being requested, you must provide a copy of your registered warranty card as proof of purchase.
Page 26
****************************** This label transcript service is offered by the Pest Management Regulatory Agency to provide efficient searching for label information. This service and this information do not replace the official hard-copy label. The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate, current or correct, and is therefore not liable for any loss resulting, directly or indirectly, from reliance upon this service.