Page 3
Before using the device, read this manual carefully for personal and equipment safety. Please keep the manual for further reference. ICON Industrial Engineering (IIE) is not liable to any personal or equipment damage caused by violation of this notice.
Page 4
Do not disassemble the device by yourself. When an anomaly occurs, contact our sales or technical support personnel. If any part is lost, contact our sales or technical support personnel to purchase the substitute. Do not purchase parts from other channels. ...
Page 5
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Contents 1 Product Overview .......................1 1.1 Small products(The shell width is 66 mm) ...............1 1.2 Large products(The shell width is 88 mm) ...............2 2 Structure and Interface .......................4 2.1 Front Panel ........................4 2.2 Top Panel ........................6 2.2.1 Low voltage(1224R / 2448R)products Top Panel ..........6 2.2.2 High voltage(AC)products Top Panel ...............6 3 Mounting ..........................7 3.1 Dimension Drawing ......................7...
Page 7
7.1 Access through Console Port ..................26 7.2 Access through Telnet / SSH..................28 7.3 Access through Web ....................29 8 Basic Features and Specifications ..................30...
Product Overview 1 Product Overview QBIT4000A includes a series of green low-consumption industrial Ethernet switches applicable to wind power, distribution network automation, subway PIS, power SCADA, petroleum and petrochemical, factory automation, intelligent transportation, rail transit, and many other industries. The series switches provide RJ45 Consoleport, and supports one-touch recovery, and network management through Web, Telnet, and console port.
ICON Industrial Engineering (IIE) Product Overview 2448R (24-48VDC, redundant power input) 1224R (12-24VDC, redundant power input) PS1-PS2:power input AC:100-240VAC,50/60Hz;110-220VDC 1.2 Large products(The shell width is 88 mm) The series switches provide either sixteen 100/1000Base-X, 10/100/1000Base-T(X) SFP slots (Gigabit SFP Slot), and four 10/100/1000Base-T(X) Ethernet ports, or four 100/1000Base-X, 10/100/1000Base-T(X) SFP slots (Gigabit SFP Slot), and sixteen 10/100/1000Base-T(X) Ethernet ports.
ICON Industrial Engineering (IIE) Structure and Interface 2 Structure and Interface Caution: It is recommended to purchase the port dustproof shield (optional) to keep ports clean and ensure device performance. 2.1 Front Panel Small product front panel Figure 1 Medium product front panel...
Page 12
ICON Industrial Engineering (IIE) Structure and Interface (11) Gigabit SFP Slot (12) 10/100/1000Base-T(X) Ethernet Port (13) 10/100/1000Base-T(X) Ethernet port speed LED (yellow) (14) 10/100/1000Base-T(X) Ethernet Port connection status LED (green) Large product front panel Figure 2 Large product front panel...
ICON Industrial Engineering (IIE) Structure and Interface (14) 10/100/1000Base-T(X) Ethernet Port connection status LED (green) 2.2 Top Panel 2.2.1 Low voltage(1224R / 2448R)products Top Panel Figure 3 Low voltage products Top Panel 2.2.2 High voltage(AC)products Top Panel Figure 4 High voltage products Top Panel...
ICON Industrial Engineering (IIE) Mounting Figure 7 Dimensions for Large Products DIN-Rail Mounting (unit: mm) Figure 8 Dimensions for Large Products Panel Mounting(unit: mm) Caution: As part of the heat dissipation system, the switch housing becomes hot during operation.
ICON Industrial Engineering (IIE) Mounting sure that the following requirements are met. 1) Environment: temperature (-40℃ to 75℃), ambient relative humidity (5% to 95%, non-condensing) 2) Power requirement: The power input is within the voltage range of the switch. 3) Grounding resistance: <5...
ICON Industrial Engineering (IIE) Mounting Step 1: Insert the head of a screwdriver into the opening of the spring locking piece at the bottom from the left. Lift the handle of the screwdriver to open the spring locking piece of the connecting seat, as shown on the left of the following figure.
Page 18
ICON Industrial Engineering (IIE) Mounting Step 4: Align the four mounting holes on the plate for panel mounting with the four screws. Make the screws pass through the Ф6.5 positions in the following figure. Move the device in direction 1 until the four screws are in the Ф4 positions. Then tighten the screws to complete mounting.
Page 19
ICON Industrial Engineering (IIE) Mounting Figure 12 Panel Dismounting Caution: Cut off the power and disconnect all cables before mounting, dismounting or moving the equipment.
ICON Industrial Engineering (IIE) Connection 4 Connection 4.1 10/100Base-T(X) Ethernet Port 10/100Base-T(X) Ethernet port is equipped with RJ45 connector. The port is self-adaptive. It can automatically configure itself to work in 10M or 100M state, full or half duplex mode. The port can also adapt to MDI or MDI-X connection automatically.
ICON Industrial Engineering (IIE) Connection Figure 14 Connection Using Straight-through/Cross-over Cable Note: The color of the cable for RJ45 connector meets the 568B standard: 1-orange and white, 2-orange, 3-green and white, 4-blue, 5-blue and white, 6-green, 7-brown and white, and 8-brown.
ICON Industrial Engineering (IIE) Connection optical/electrical module to enable data transmission. Note: The device uses the SFP module that supports digital diagnosis to support the optical power detection function of the SFP slot. For details about the SFP module, consult our sales or technical support personnel.
Page 24
ICON Industrial Engineering (IIE) Connection Device B, connect the TX port of Device A to the RX port of Device B, and the RX port of Device A to the TX port of Device B, as shown in the following figure.
ICON Industrial Engineering (IIE) Connection fiber (<20km) for connection. If such a short fiber is used, the module will be burned. 4.3.2 SFP Electrical Module Figure 20 SFP Electrical Module How to Connect the SFP Electrical Module Insert the SFP electrical module into the SFP slot in the switch, and then insert the RJ45 connector of the twisted pair into the SFP module.
ICON Industrial Engineering (IIE) Connection serial port of a PC, and the other end is crimped RJ45 connector to be inserted into the console port of the switch. Figure 23 Wiring Sequence of DB9-RJ45 Console Cable Table 6 Pin Definitions of DB9 Port (9-Pin Serial Port) and RJ45 Port (Console Port)
ICON Industrial Engineering (IIE) Connection Caution: Before connecting the device to power supply, make sure that the power input meets the power requirement. If connected to an incorrect power input, the device may be damaged. To comply with UL restrictions, this equipment must be powered from a source compliant with Class 2.
Page 30
ICON Industrial Engineering (IIE) Connection Note: Pin 1 and pin 2 are normally-open contacts; pin 2 and pin 3 are normally-closed contacts. When the switch works properly, pin 1 and pin 2 are closed, pin 2 and pin 3 are open; when an alarm occurs, pin 1 and pin 2 are open;...
ICON Industrial Engineering (IIE) Reset 5 Reset The device provides a Reset button on the front panel. The button can be used to restart the device or restore factory default settings. You can restart the device by pressing and holding the button for 0.5 to 3 second.
ICON Industrial Engineering (IIE) LEDs 6 LEDs Table 11 Front Panel LEDs State Description Power 1 is connected and operates properly. Power 1 LED Power 1 is not connected or operates abnormally. Power 2 is connected and operates properly. Power 2 LED Power 2 is not connected or operates abnormally.
ICON Industrial Engineering (IIE) Switch Access 7 Switch Access You can access the switch in any of the following ways: 7.1 Access through Console Port Step 1: The RJ45 management port connects the 9-pin serial port of the PC and the Console port of the device through the DB9-RJ45 Network cable Equipment attached.
Page 34
ICON Industrial Engineering (IIE) Switch Access Figure 28 Selecting a Serial Port Note: To confirm the communication port in use, right-click [My Computer] and select [Property]. Click [Hardware] → [Device Manager] → [Port] to view the communication port. Step 5: Set port parameters (Bits per second: 115200, Data bits: 8, Parity: None, Stop bits: 1,...
ICON Industrial Engineering (IIE) Switch Access Figure 29 Setting Port Parameters Step 6: Click OK to enter the switch CLI. Then the following commands can be used to perform operations. Table 12 CLI Commands View Command Description Privileged mode SWITCH#show interface vlan 1 Query the IP address of the switch.
ICON Industrial Engineering (IIE) Switch Access Figure 30 Access through Telnet Step 3: Click OK. The Telnet CLI is displayed. Then you can run the commands (as shown in Table 12) to perform operations. 7.3 Access through Web Step 1: Connect the network port of a PC to the Ethernet port of the switch with a network cable.
ICON Industrial Engineering (IIE) Basic Features and Specifications 8 Basic Features and Specifications Power Requirements Maximum Voltage Power Identifier Rated Voltage Range Range 2448R 24-48VDC 18-72VDC 1224R 12-24VDC 9-36VDC 100-240VAC,50/60Hz;110-220VDC 85-264VAC/77-300VDC L2/L5:5-pin 5.08 mm-spacing plug-in terminal block Terminal block HV:3-pin 7.62 mm-spacing plug-in terminal block...
Page 38
ICON Industrial Engineering (IIE) Basic Features and Specifications Warranty Warranty 5 years...
Page 39
ICON Industrial Engineering (IIE) TEL: +7 (495) 666-29-11 Website: http://iie.ai Email: support@icon-group.ru For more information about IIE products, please visit our website: http://www.iie.ai...
Need help?
Do you have a question about the QBIT4000A and is the answer not in the manual?
Questions and answers