Juren DZ-1B User Manual

Home oxygen generator

Advertisement

DZ-1B Home oxygen generator
!"#$%"&'()!(*
Please read the manual before use
!
table of Contents
!"#$%&$'%( .............................................................................................................................. 1
) *"+&%,-./'012"30&"2-3%".2% ......................................................................................... 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DZ-1B and is the answer not in the manual?

Questions and answers

Summary of Contents for Juren DZ-1B

  • Page 1 DZ-1B Home oxygen generator !"#$%"&'()!(* Please read the manual before use table of Contents !"#$%&$'%( ..........................1 ) *"+&%,-./'012"30&"2-3%".2% ..................2...
  • Page 2 4*"5/&.,/.&-6",7-&-,/%&'2/',2"-18"(0&9'1:";&'1,';6% ........3 4. Technical characteristics ....................5 <*"=1;-,9'1:"-18"'12/-66-/'01 ..................7 >*"=2%"-18"0;%&-/'01 ......................9 ?"@-.6/"-1-6A2'2"-18"/&0.B6%2700/'1: ..............11 C*"D-'1/%1-1,%"-18",-&% ....................12 9. Transportation and storage ................... 14 !E*"F-&&-1/A";%&'08"-18"-3/%&G2-6%2"2%&$',% ............ 15 !!*"+-,9'1:"6'2/H"2.;;0&/'1:"-,,%220&'%2"2;%,'3',-/'012 ......16...
  • Page 3 1.1 Product Features The DZ-1B household oxygen generator is one of the series of products produced by our company. The product uses molecular sieve as the adsorbent, uses the advanced pressure swing adsorption (PSA) principle, and uses air as the raw material to produce oxygen through physical means.
  • Page 4 " #$%&'()*+,-./$0-&$/)0'$*/'$ When using this product, please observe the following safety precautions: oxygen is a combustion-supporting gas ,it is not allowed to use the oxygen generator in an environment with bright or dark fire source or with flammable or explosive danger. Smoking is strictly prohibited near the oxygen inhaler It is not allowed to place the oxygen tube under the bedspread or seat cushion .
  • Page 5 1#$2+&*(+*&)3$(4)&)(+'&,/+,(/$).5$6-&7,.8$9&,.(,93'$ Control panel and display Oxygen outlet Tele control reception Atomization switch and outlet Humidifying cup Carry Nameplate handle Inlet silencer filter switch Vents power cable Figure 1 DZ-1B domestic oxygen generator outline drawing - 3 -...
  • Page 6 1#$2+&*(+*&)3$(4)&)(+'&,/+,(/$).5$6-&7,.8$9&,.(,93'$ 3.2 Working principle The oxygen flow of DZ-1B oxygen generation mechanism is shown in Figure 2: Figure 2 Oxygen flow diagram of the oxygen generation mechanism The DZ-1B type domestic oxygen generator uses molecular sieve as the adsorbent and uses the principle of pressure swing adsorption (PSA) to filter the air and send it to the molecular sieve adsorption tower for pressure adsorption and decompression.
  • Page 7: Technical Characteristics

    . Technical characteristics $ 4.1 Use environment Ambient temperature: 10 ℃ ~ 40 ℃ Relative humidity 30% ~ 75% Atmospheric pressure 86.0kPa ~ 106.0kPa 220 -240V(+5/-10V) Power frequency 50Hz ± 1Hz 4.2 Working conditions Impurities in raw air ≤ 0.3 mg / cm Oil content in the air ≤...
  • Page 8 . Technical characteristics 4.4 Technical indicators Oxygen concentration(when the flow≤1 liter) 90 ± 3% (v / v) Carbon dioxide content ≤0.01% (v / v) Smell Odorless Particle size of solid matter ≤10um Solid matter content ≤0.5mg / m Product technical indicators: Adjustment range (1 ~ 7 L / min)可调...
  • Page 9: Installation Precautions

    :#$;.9)(7,.8$).5$,./+)33)+,-.$ 5.1 Unpacking Open the box from the top surface of the box, remove the foam, open the plastic bag, pull the back cover handle, and take out the oxygen generator. 5.2 Inspection First check the oxygen generator for transportation damage, and then check the accessories and random documents according to the packing list.
  • Page 10 :#$;.9)(7,.8$).5$,./+)33)+,-.$$ inserted into the water injection hole, and an appropriate amount of pure water is poured into the humidification cup through the funnel (the liquid level should not exceed the highest water level line). Take out the funnel, plug the water injection silicone plug at the water injection hole, and then insert the humidification cup Back (see Figure 3).
  • Page 11: Precautions For Use

    The power must be turned off and the machine cooled down before being used. 6.2 Use The touch display control panel of DZ-1B oxygen generator is shown in Figure 4: Figure 4 Control panel of DZ-1B oxygen generator - 9 -...
  • Page 12 >*"=2%"-18"0;%&-/'01" 1) Turn on the power: Plug in the power cord and turn on the power. Turn on the power switch (located at the bottom of the back of the oxygen generator), the oxygen generator starts, and the touch button at the bottom of the screen lights up to enter the standby state.
  • Page 13 =$>)*3+$).)3?/,/$).5$+&-*@3'/4--+,.8$ "continuous oxygen" The oxygen generator can be completely powered off and shut down. If you have a problem using the oxygen generator, please read this chapter carefully before sending it for repair. You may be able to solve the problem yourself very easily. If you cannot solve the problem successfully according to the suggestions in this chapter, please unplug the oxygen generator and send it for repair.
  • Page 14: Maintenance Precautions

    A#$B),.+'.).('$).5$()&'$ 8.1 Maintenance precautions When performing maintenance, please observe the following precautions: Maintenance precautions 1. If the oxygen generator fails, you should contact the dealer or the manufacturer for repair. Only personnel authorized by the manufacturer can debug and repair the oxygen generator. Do not disassemble and repair it by yourself.
  • Page 15 !"#$%&'()'%'*)#%'+#*%,)# 8.5 Cleaning the oxygen pipe The oxygen tube supplied by the oxygen generator is a single-use sterilized product and should be replaced by a special person. It should be replaced regularly. The nose of the oxygen tube should be cleaned and disinfected after each use.
  • Page 16: Precautions For Transportation And Storage

    9. Transportation and storage 9.1 Precautions for transportation and storage Please observe the following precautions during transportation and storage: Precautions for transportation and storage 1. Before the oxygen generator is transported or stored, the water in the humidification cup should be drained. 2.
  • Page 17 !C#$D)&&).+?$9'&,-5$).5$)0+'&E/)3'/$/'&F,('$ " 10.1 Warranty period Since the product was sold, the warranty period is as long as the requirements for handling, storage, use and maintenance are observed. One year, and the product usage time is less than 3000 hours. If one of the following situations occurs, it does not belong to our company Free warranty coverage: 1) Damage caused by the user's incorrect operation or use under abnormal conditions.
  • Page 18 "oxygen output" socket of the oxygen generator. Users can purchase according to the sample specifications in the random accessories. Avoid adverse effects on safety. 11.2 Packing List Table 2 Packing list of DZ-1B domestic oxygen generator Serial Quantit Notes model...
  • Page 19: Warranty Card

    warranty card Purchase account: Order number: contact number: Shipping address: Receiving Name: Reason for repair: Date of purchase: "#$%&'%#%(')*'(+,-).+,/) D-'1/%1-1,%" J%;-'&" 8-/%" @-'6.&%";7%10I%101" &%,0&82" I-1" " " " " " " " " " " " " D)&&).+?$()&5$5'/(&,9+,-.$ After the user purchases the product, the user information of the warranty card should be filled in and kept properly.

Table of Contents