Temperature regulator
Hide thumbs Also See for OB-30:

Advertisement

Temperature Regulator
OB-6
Direct acting type
Pilot operated type
Bellows
Diaphragm
Soft seat
Features
1. Low leakage designed single-seat valve.
2. Small and light weight compared with other temperature
regulators.
3. These temperature regulators do not require any adjusting tool
because equipped with an adjusting handle which leads to easy
adjustment.
4. Excellent accuracy since special packing is used for spindle
gland packing which affects opening/closing operation of the
valve.
Specifications
Application
Max. pressure
Maximum temperature
Temperature
adjusting range
Ambient temperature
Valve seat
Material
Valve spindle
13
Thermal
valve
Standard capillary length
Connection
* Valve seat leakage: Refer to P. -43.
∙ Available with capillary of up to 5 meter. (Please refer to P. -46 for errors of set temperature).
∙ Available with low-temperature heating (15-35˚C, 20-40˚C, 35-55˚C) for OB-6G.
∙ Available with thermal well (SUS304 made or with a PTFE cap) for liquid.
∙ Available with temperature adjusting range of 30˚C (OB-6 only).
Temperature Adjusting Range
-31
13
Heating
Cooling
Single valve
Double valve
Heating
Heated
Body
Thermal valve
For liquid
For air
Body
Valve
Bellows
For liquid
For air
Temperature adjusting (°C)
For liquid
40-60
50-70
60-80
80-100
100-120
· The term "Withstand temperature" means the temperature
from pressure resistance of the bellows.
Steam, Hot water
Cold and hot water, Oil, Non-dangerous fluid
0.5 MPa
1.0 MPa
180°C
40-120°C
40-120°C
Set temp. -10˚C or less
Cast iron
Stainless steel
Stainless steel
Stainless steel
Phosphor bronze
Stainless steel
Stainless steel with fin
JIS 10K FF flanged
Withstand
temperature (°C)
For air
40-60
50-70
60-80
80-100
100-120
www.yoshitake.jp
2 m
70
80
90
110
130