Summary of Contents for DAESUNG MAREF Doctor Life Lx9max

  • Page 1 EN ISO 13485 : 2016 ISO 13485 : 2016 USER MANUAL Read this manual carefully. This manual is for user's safety Indications and previewing any property-loss. Before using our device, for safety use please read this manual inevitably.
  • Page 2: Table Of Contents

    1. Introduction CONTENTS 1-1. LX9max Introduction … 03 1-2. Indication for use … 03 1-3. Target treatment group and diseases … 03 1-4. Contraindications … 04 1-5. Side effect … 04 2. Caution for safety 2-1. Caution for electric safety …...
  • Page 3: Lx9Max Introduction

    Information 1-1. LX9max Introduction Thanks for purchasing LX9max. This product is an Intermittent Pneumatic Compression system to temporarily relieve minor muscle aches and pains and for temporary increase in circulation to the treated areas in people who are in good health. The operating principle is that the air from the device will be delivered to the sleeve with 4 air chambers and the air pressurizes sequentially the chambers from 1st to 4th.
  • Page 4: Contraindications

    1-4. Contraindications - Acute Neuropathy and Plexopathy - Acute Pulmonary Edema - Acute Soft-tissue Trauma - Acute Thrombophlebitis - Deep vein thrombosis (DVT) - Uncompensated Cardiovascular Diseases - Epilepsy - Febrile Conditions - Glaucoma - Hepatic or Renal Insufficiency - Infectious Diseases - Ischemic vascular disease - Known (or Suspected) Deep Vein Thrombosis - Lymphangitis...
  • Page 5: Caution For Safety

    Caution for safety 2-1. Caution for electric safety - When this product is not in use, disconnect the power cord. - When thunder and lightning cause a sudden blackout, turn off this product and disconnect the power plug. (There is a risk of product failure or electric shock.) - Accurately connect the power cord so that it is rigidly plugged in.
  • Page 6 - Do not use wet hands or other wet body parts to touch this product, the power cord, plug and socket. (There is a risk of electric shock which may cause injury.) - Do not damage, bend, twist, or heat up the power cord. (When the cord is damaged, there is a risk of fire and electric shock.) - When you smell something abnormal while this product is in use, immediately stop using this product.
  • Page 7: Cautions Prior To Use

    2-2. Cautions prior to use - Check whether or not this device is damaged and whether or not this device functions properly at least once per year. (When this device is used without conducting maintenance, there is a risk of malfunction and injury.) - Do not use this product for any purposes other than the intended use.
  • Page 8: Cautions During Use

    - The accessories and parts to be used in product must be of those provided or approved by DAESUNG MAREF. (When any accessories and parts not approved by DAESUNG MAREF are used, there is a risk of malfunction which may not guarantee user safety.) 2-3.
  • Page 9: Cautions After Use

    2-4. Cautions after use - When disconnecting the power cord from the device, disconnect the power cord from the socket prior to removing it from this product. - Prior to cleaning this product, disconnect the power cord from the socket and then disconnect the power cord from this product.
  • Page 10: Sleeve Use And Storage Related Cautions

    - Store this sleeve in a place that cannot be reached by children. - The sleeve is intended to be connected with the product manufactured by DAESUNG MAREF only. Do not connect the sleeve with other products manufactured by other companies.
  • Page 11: How To Clean

    2-6. How to clean 2-6-1. How to clean the device - If any foreign materials get on the device, first turn off the device and use a soft cloth to wipe the device with a bit of water or a neutral detergent. (It may cause discoloration, damage or malfunction.) - If you sanitize product, first turn off the device and wipe off with soft cotton using neutral detergent.
  • Page 12: Operation / Storage Conditions

    2-7. Operating / Storage condition 2-7-1. Operating conditions ℉ Relative humidity (%) Atmospheric Pressure (hPa) Temperature ( 2-7-2. Storage conditions ℉ Temperature ( Relative humidity (%) Atmospheric Pressure (hPa)
  • Page 13: Weee

    LX9max is a recoverability rate of 79.30% and a recyclability rate of 73.51%. Information for treatment facilities shall be made available to centres which prepare for re-use and treatment and recycling facilities by producers of EEE. DAESUNG MAREF, whenever, is prepared to provide.
  • Page 14: Product Package

    Product package 3-1. Basic set User manual LX9max (Device) Double tubing Leg sleeve (1 Pair)
  • Page 15: Accessories

    3-2. Accessories Arm sleeve Center body sleeve Extension zipper Single tubing (Leg, Arm) ※ Sleeve and tubing are articles of consumption.
  • Page 16 * Accessories Information Names Size Ref.No. 4LAGL5A LEG SLEEVE 4LAGX40 GENERAL 4LAGY00 SLEEVE ARM SLEEVE 4AAGF3A CENTER BODY SLEEVE 4SAGF5A 4ELGL02 LEG EXT. ZIPPER 4ELGX01 EXTENSION 4ELGY00 ZIPPER ARM EXT. ZIPPER 4EAGF02 CENTER BODY EXT. ZIPPER 4ECGF01 SINGLE TUBING 1000370 OTHER DOUBLE TUBING 1000380...
  • Page 17: Size Of Sleeve And Zipper Size

    3-3. Size of sleeve and zipper size 3-3-1. Size of General sleeve Leg sleeve dimension Thigh Extension Thigh Ankle Size Length (+extension) (+extension) 62cm 41cm 74cm (72cm) (48cm) Length 75cm 43cm 79cm (85cm) (50cm) Extension zipper 76cm 46cm 94cm Ankle (86cm) (53cm) Arm sleeve dimension...
  • Page 18 Center body sleeve dimension Girth Extension Girth Size Length (+extension) Length 108cm Free 74cm (118cm)
  • Page 19: Product Description

    Product description 4-1. Device specifications Items Specification Model LX9max Protection Type Class II, BF-type Device AC100-127V, 50/60Hz Rated Voltage AC200-240V, 50/60Hz Power Consumption 60VA Setting Pressure 10-180mmHg ±20mmHg (Unit: 10mmHg) Time range 5-90min (Unit: 5min) Speed 1-6 level Mode A, B, C, D Dimension 260(W) x 180(D) x 130(H)mm Weight...
  • Page 20: Appearance And Names And Functions Of Buttons

    4-3. Appearance and Names and Functions of Buttons. Name Function Setting pressure / display A window that displays the pressure setting. Setting time / display A window that displays the time setting. Setting speed / display A window that displays the pressure speed setting. Knob that control the operational pressure, time, speed of Control knob the device.
  • Page 21: Product Use And Procedure

    Product use and procedure 5-1. Before using a device Please check the condition of the sleeve and device before use. Please make yourself as a comfortable posture for best effects. 5-2. Setup and use 1) Place the device on a hard and flat table. 2) After checking that the power cord is not kinked or damaged, connect it to a power outlet.
  • Page 22: Mode Setting

    - Press button of the function that you want to set, and use the control knob to change setting. (When you press button, it will flicker, which means you can change the setting.) To decrease the pressure To increase the pressure Turn the pressure device Turn the pressure device to the left for decreasing the...
  • Page 23 ④ ④ ④ ③ ③ ③ ② ② ② ① ① ① - All sleeves are composed of 4CH and operate the same according to each mode. ×6 times - In A mode, each chamber is inflated one by one from foot to thigh then deflate.
  • Page 24 - In B mode , all chambers from foot to thigh are sequentially inflated and deflated simultaneously. - In C mode, inflation is applied twice in forward direction from foot to thigh and then once in reverse direction. - In D mode, four chambers are simultaneously inflated and deflated.
  • Page 25: Skip Care Mode Setting

    5-5. Skip care mode setting - Skip care mode can choose any chamber you want to have the massage. - It is not only able to set up on each A~D mode, but also set up during the operating. 5-6. How to connect the tubing to the device - Plug in the tubing to the air socket.
  • Page 26: Troubleshooting

    Troubleshooting 6-1. General Troubleshooting Problem Cause Solution Power connection Check that the plug is correctly inserted into No electric power error the power outlet Power on but not Power supply error Turn power to the device off and on operating Check that the device is installed horizontally Noisy during...
  • Page 27: Information On Emc

    Information on EMC Basic EMC Operating Phenomenon standard or test Port tested Test Voltage Test level/requirement mode method Mains terminal AC 120V,60Hz disturbance CISPR11:2015 Operating AC Mains AC 220V,60Hz Group1, Class A voltage AC 230V,50Hz AC 120V,60Hz Radiated CISPR11:2015 Operating Enclosure AC 220V,60Hz Group1, Class A...
  • Page 28 Immunity to 0.15-80 MHz Conducted EN 61000-4-6:2014 AC 120V,60Hz Operating 6 V in ISM bands Disturbances IEC 61000-4- AC Mains AC 220V,60Hz Stand by Between 0.15 MHz Induced by 6:2013 AC 230V,50Hz and 80 MHz RF fields 80% AM at 1 kHz Power Frequency EN 61000-4-8:2010 AC 120V,60Hz...
  • Page 29: Symbols Information

    Symbols Information Symbols Explanation Reference ISO 15223-1 Manufacturer 5.1.1 ISO 15223-1 Date of Manufacture 5.1.3 ISO 15223-1 Serial Number 5.1.7 WEEE Label with marking bar EN 50419 IEC 60878 Type BF applied part 5333 Increase Direction Custom Symbol Decrease Direction Custom Symbol IEC60878 ON / OFF...
  • Page 30 ISO 7000 This way up 0623 ISO 7000 Do not hang on hooks in the box 0622 ISO 15223-1 Fragile, handle with care 5.3.1 ISO 15223-1 Keep dry 5.3.4 ISO 15223-1 Consult instructions for use 5.4.3 ISO 7010 Refer to instruction manual M002 ISO 7000 Stacking limit by Number...
  • Page 31 Digital System Custom Symbol Low noise design Custom Symbol Easy Operation Custom Symbol Wide Pressure Range Custom Symbol...
  • Page 32 MEMO...
  • Page 33 MEMO...
  • Page 34 MEMO...
  • Page 35 Warranty Much appreciated on using our device. We, DAESUNG MAREF are doing our best to improve the quality of our products. ※ We can not be responsible for any defect occured from user's careless use or in case of followings, even though warranty period : 1.
  • Page 36 - Established DAESUNG Machinery Company - Awarded the Governor's Citation for Day of Commerce and Industry by 1994 Gyeonggi province - Conversion to DAESUNG MAREF CO.,LTD. 2011 1999 President Award - Registered DOCTOR LIFE - Gold Listed at the Korea Precision...

Table of Contents