Contents Page Declaration Information & General Warnings Introduction Symbols used in the manual Delivery of the appliance and the User Manual Guarantee and responsibility Liquid fuel information and general instructions Product disclaimer statement Safety and Prevention Introduction Health and Safety information Appliance Introduction Appliance panel descriptions Checking the characteristics of the appliance...
This will be extended to a total period of 5/10 years if the appliance is registered with EOGB Energy Products Ltd within thirty days of installation and it is serviced at twelve month intervals. See main Terms and Conditions below.
Page 5
EOGB Energy Products Ltd will not be liable for any charges arising from this process. If a fault covered by the manufacturer’s guarantee is found Ask your Sapphire Agent to contact EOGB Energy Products Ltd Service Department on +44 (0)1480 477066 who will arrange for a competent service engineer to rectify the fault.
Information. Information is supplied upon the condition that the persons receiving will make their own determination as to its suitability for their purposes prior to use. In no event will EOGB (and its subsidiaries) be responsible for damages of any nature what- soever resulting from the use of or reliance upon Information.
Please note that the installation, commissioning and servicing MUST only be carried out by a competent, qualified engineer, trained and registered to generic industry standards of competence and who has undertaken additional EOGB manufacturers appliance and burner specific training. In accordance with BS5410 part 1 2019.
Sapphire Modulating Blue Flame Burner Technical description of the burner Fully modulating low NOx burner for domestic heating EOGB’s Sapphire blue flame burner delivers excellence in performance and reliability, backed by first-class technical expertise and a personable, responsive service. Low NOx – High performance Sapphire has been designed from the outset to bring about a step-change improvement in domestic heating performance.
Check and establish if the liquid fuel in the tank is suitable for this boiler specification Check that there are filters fitted with the correct filtration requirements See EOGB Sapphire Boiler Installation Manual Ensure the oil supply is correctly connected.
Any attempt to fire or commission this appliance by Step 2 - Upon successful loading, the “Temperature Display unauthorized persons will invalidate the appliance Screen” will be displayed. Fig. 10 Press the “EOGB Logo” warranty. WARNING in the top left hand corner to open the “System Ramp Test Screen”.
Page 13
Fig. 12 Fig. 17 Fig. 13 Fig. 18 Step 5 - Once you reach the “Run Time System Control Screen” press the “Start” button Fig. 19 Fig. 14 Fig. 19 The burner will begin its start sequence and will attempt to establish a flame on “Pump Pressure (bar)”...
Page 14
Boiler Operation and Commissioning Step 6 - Once the air has been Then press the + or - buttons to increase/decrease the bled from the fuel pump the burner should have established a flame on “Pump pump pressure setting (min 5bar to max 20bar depending Pressure (bar) Setting 7 Bar* on boiler model).
Fig. 26 buttons to adjust “Max CH Setpoint” Fig. 30 Please note that EOGB pre-set and highly recommend this The burner will then reset. Once the burner has been setting to be left at 70 °C to ensure correct flow and return successfully commissioned the screen will display the water temperatures for the system design.
Maintenance / Service Maintenance & service Notes on safety for the maintenance Periodic maintenance is essential for the good operation, safety, yield and duration of the burner. It allows you to reduce consumption and polluting emissions and to keep the product in a reliable state over time. The maintenance interventions and the calibration of the burner must only be carried out by a Sapphire Approved Agent, in accordance with the contents of this manual and in compliance with the standards and regulations of current laws.
Maintenance / Service Replacing the nozzle As part of a burner service, the oil nozzle must be replaced. With the oil pipe assembly removed, the nozzle can then be changed. Fig. 35 To access the nozzle simply loosen the nozzle holding plate fastening screws.
Maintenance / Service Servicing of the boiler plate sealing gasket, blast tube, electrodes, air bush and flame detector sight glass Once removed, the Boiler Plate Sealing Gasket can be IMPORTANT - Ensure the boilers electrics have been checked for damage and replaced if necessary. Fig. 42 isolated safely before carrying out any service works DANGER Before removing the burner for service, please ensure...
Page 19
Maintenance / Service To change or inspect the ignition electrodes, loosen and To access and clean the site glass, loosen and remove the remove the fixing bolt and slide each electrode out. Fig. 46 fastening bolts to remove the plate. The sight glass and gas- ket can then be inspected/cleaned.
33-35 Sapphire 32 kW 23-25 33-35 EOGB recommends that a cleaning solution such as The nozzle assembly can be adjusted by increasing/de- SCALEBREAKER LS3 from KAMCO or other spray on liquid creasing the brass adjustment nut. boiler cleaner compound be used. (see cleaning product...
Maintenance / Service Condensate pump/trap During the service the condensate trap and pump must be checked before cleaned. To check/clean the trap, disconnect the push on flexible grey waste discharge hose from the trap. Check and clean this hose if required. Caution, the waste discharge hose may contain some condensate.
Boiler Exploded Casings View Fig. 59 Labelled Number Part Number Description SS-CASE-022-01 Boiler Top Casing Panel - BRILLIANT WHITE SS-CASE-007-01 Stud Latch M5 SS-CASE-025-01 Boiler Right Casing Panel - BRILLIANT WHITE SS-CASE-008-01 Clip Latch SS-CASE-006-01 M5 Spring U Clip SS-CASE-024-01 Boiler Left Casing Panel - BRILLIANT WHITE SS-CASE-008-01 Clip Latch...
Boiler Exploded Components View Fig. 60 Please refer to the next page to find spare part identification SP - MAN - SERVICE - 01 Revision 2 21/12/2021...
Page 24
Boiler Exploded Components View Labelled Number Part Number Description SS-ACCESS-005-01 Flue Air Adaptor Intake SS-ACCESS-006-01 M6 x 16 Hex Socket SS button bolts SS-ACCESS-008-01 Flue Air Adaptor Intake gasket SS-ACCESS-004-01 Air Intake Flue Adaptor SS-LOOM-009-01 PT sensor cable SS-ACCESS-006-01 M6 x 16 Hex Socket SS button bolts SS-HEX-009-01 HEX Flue Blanking Plates SS-HEX-003-01...
Top Tray Exploded View Fig. 61 Labelled Number Part Number Description H01-42002116-002 Wiring centre – 10-way junction box SS-WIRE-007-01 USB 5v Power Supply SS-WIRE-009-01 Spacer for USB 5v Socket SS-CASE-028-01 Pump Mounting Bracket - SS D01-071N4106 BFPM61 Oil Pump D01-071N1006 BFPM61 Solenoid coil D01-071N4214 BFPM61 Motor lead...
Oil Line Connections View Fig. 64 Labelled Number Part Number Description F11-0440-A-14M-S-14F Flexible 440mm Ruby Red Angled 1/4M x 1/4F SS-CASE-031-01 Nozzle Holder Service Support clip SS-HEX-021-01 1/4” Male/Female Elbow SS-HEX-020-01 1/4”BSP Tee M/F/M SS-HEX-016-01 1/4” Male/Female Isolation Valve (Bio) SP - MAN - SERVICE - 01 Revision 2 21/12/2021...
Fault Codes 10.0 Boiler lockouts and fault codes In the event of a failure, the boiler will go into a lockout phase. The cause of the lockout could be down to a number of things but an error code will be displayed on the boiler panel LCD screen. FIG 65 This error code can be looked up below to provide possible causes of the fault.