C.E. Nierhoff & Co C815 Troubleshooting Manual

Alternator

Advertisement

Quick Links

C.E. Niehoff & Co.
R
CONTENTS
Section 1:Wiring .................................................................2
Section 2: Basic Troubleshooting .....................................3
Section 3: Advanced Troubleshooting .............................4
Battery Charging Conditions
The following conditions may be observed during cold-
start voltage tests until temperatures of electrical system
components stabilize. The time it takes to reach optimum
voltage and amps will vary with engine speed, load, and
ambient temperature.
Maintenance/Low Maintenance Lead-Acid Battery:
Traditional lead acid batteries require lowest charge volt-
age of all vehicle battery chemistries. Battery cells must
be maintained by periodically topping off with distilled
water as required.
Maintenance-free Lead-Acid Battery:
Maintenance-free batteries are similar to Maintenance/
Low Maintenance batteries, but may require slightly higher
charge voltage.
Deep-cycle/Marine Maintenance-free Battery:
Charge acceptance of these batteries may display charac-
teristics similar to maintenance-free batteries and may
charge faster due to generally lower capacity relative to
size.
AGM (Absorbed Glass Mat) Maintenance-free Battery:
These dry-cell batteries respond better than standard
maintenance-free batteries. If battery state of charge
(SOC) drops to 75% or less, batteries should be
recharged to 95% or higher separately from engine charg-
ing system to avoid damaging charging system
components and to provide best overall performance.
Charge acceptance of these batteries may display charac-
teristics similar to maintenance batteries, but may require
higher charge voltage and will draw significant current (<100
amps) when under 50% SOC.
Lithium Battery:
Lithium batteries have unique charging characteristics that
differ from lead acid. These batteries require charging
systems configured specifically for lithium battery chemis-
tries. Contact CEN for more information on lithium battery
charging systems and components.
Testing Guidelines
Professional service technicians rely on the following
guidelines when testing electrical components.
TG7B
Voltage testing:
Set meter to proper scale and type (AC or DC).
Be sure to zero the meter scale or identify the meter
burden by touching meter leads together. Meter burden
must be subtracted from final reading obtained.
Be sure the meter leads touch source area only.
Prevent short circuit damage to test leads or source by
not allowing meter leads to touch other pins or exposed
wires in test area.
Be sure to use CEN tools designed especially for trou-
bleshooting CEN alternators when available.
Resistance (ohm) testing:
Set meter to proper scale.
Be sure to zero the meter scale or identify the meter
burden by touching meter leads together. Meter burden
must be subtracted from final reading obtained.
Be sure meter leads touch source area only. Allowing
fingers or body parts to touch meter leads or source
during reading may alter reading.
Be sure reading is taken when source is at 70ºF. Read-
ings taken at higher temperatures will increase the
reading. Conversely, readings taken at lower tempera-
tures will decrease the reading.
Be sure to test directly at the source. Testing through
extended harnesses or cable extensions may increase
the reading.
"OL" as referenced in this document refers to open cir-
cuit: "infinite" resistance, typically in very high kilo- or
megaohm range depending on meter and settings.
Diode testing:
Diodes allow current to flow in one direction only. Typi-
cal voltage drop in forward bias can range from 0.1-
0.85V. Meter should read OL in reverse bias. Check
meter user manual for meter-specific testing guidelines.
Voltage drop testing:
Measure voltage between B+ on alternator or power
source and B- (ground) on alternator or source. Record
reading. Move to batteries or other power source and
measure again between B+ and B- terminals on battery
or other power source. The difference between the two
readings represents voltage lost within circuit due to,
but not limited to, inadequate cable gauge or faulty con-
nections.
Voltage drop measurements must be taken with all elec-
trical loads or source operating.
Dynamic/Live testing (Connecting power and ground to
component to test operation/function out of circuit):
Connect jumper leads directly and securely to power
source contacts of component being tested.
Make any connection to power and ground at power
supply or battery source terminals. Do not make con-
nection at component source terminals, as that may
create an arc and damage component source terminals.
C715/C716 Alternators
Troubleshooting Guide
Page 1

Advertisement

loading

Summary of Contents for C.E. Nierhoff & Co C815

  • Page 1 C715/C716 Alternators C.E. Niehoff & Co. Troubleshooting Guide CONTENTS Voltage testing: • Set meter to proper scale and type (AC or DC). Section 1:Wiring ..............2 Section 2: Basic Troubleshooting ........3 • Be sure to zero the meter scale or identify the meter Section 3: Advanced Troubleshooting ......4 burden by touching meter leads together.
  • Page 2 Section 1: Wiring Diagram C. E. Niehoff & Co. Section 1: Wiring Diagram BRUSHLESS ALTERNATORS CEN C715 and C716 Alternators B+ Terminal Description and Operation .+ Terminal C715 C715 C716 C716 The C715 C715 C715 alternator (14 V, 360 A) and C716 C716 C716 alterna- tor (14 V, 400 A) are internally rectified.
  • Page 3 Section 2: Basic Troubleshooting C. E. Niehoff & Co. Section 2: Basic Troubleshooting BRUSHLESS ALTERNATORS D. Basic Troubleshooting A. Tools and Equipment for Job • Digital Multimeter (DMM) Inspect charging system components Inspect charging system components Inspect charging system components Inspect charging system components Inspect charging system components for damage...
  • Page 4 Section 3: Advanced Troubleshooting C. E. Niehoff & Co. Section 3: Advanced Troubleshooting BRUSHLESS ALTERNATORS è Chart 1 – System Circuit START HERE Is there a battery isolator in the system? Install temporary jumper between one battery terminal and alternator terminal on isolator. Use minimum 12 AWG wire. Do not operate charging system more than two CAUTION minutes with jumper installed.
  • Page 5 Section 3: Advanced Troubleshooting (cont.) C. E. Niehoff & Co. Section 3: Advanced Troubleshooting BRUSHLESS ALTERNATORS (CONT’D) Ener Energize Switch Ener gize Switch gize Switch – Test Charging Circuit gize Switch Chart 2 – No Alternator Output – Ener Ener gize Switch STATIC TEST –...
  • Page 6 Section 3: Advanced Troubleshooting C. E. Niehoff & Co. Section 3: Advanced Troubleshooting BRUSHLESS ALTERNATORS (CONT’D) Chart 3 – No Alternator Output – Ignition Switch Ignition Switch Ignition Switch Ignition Switch – Test Charging Circuit Ignition Switch STATIC TEST – ENGINE O.., BATTERY SWITCH ON, KEY ON Test for battery voltage at B+ terminal on alternator to ground, then at F+ terminal on regula- tor to ground.
  • Page 7 C. E. Niehoff & Co. Notes BRUSHLESS ALTERNATORS If you have questions about your alternator or any of these test procedures, or if you need to locate a Factory Authorized Service Distributor, please contact us at: C. E. Niehoff & Co.• 2021 Lee Street • Evanston, IL 60202 USA TEL: 800.643.4633 USA and Canada •...