Summary of Contents for KayserBetten Ida 98 1.0

  • Page 1 Instruction manual Electrically adjustable care bed Ida 98 1.0 8 doors with insert frame KR3...
  • Page 2 Instruction manual for care bed „Ida 1.0“ SAVE FOR FUTURE USE. READ CAREFULLY!
  • Page 3: Table Of Contents

    Instruction manual for care bed „Ida 1.0“ Table of contents 1 Introduction ........... 5 5 Assembly ..........18 Preface ............ 5 Personnel qualifications ......18 Manufacturer .......... 5 Specific safety instructions ....18 Warranty ..........6 Unpacking care bed ......18 Conformity declaration ......6 Assembling care bed ......
  • Page 4 20 A ttachments ......... 45 Cleaning care bed ......... 37 Maintenance / Safety Inspection Record Disinfecting care bed ......37 (STK) for KayserBetten ......45 Maintenance and repair ......45 10 M aintenance ......... 37 Training record ........45 11 T rouble shooting guide ......38 12 R epair ...........
  • Page 5: Introduction

    Introduction Preface Dear customer, thank you for the trust you have placed in the KayserBetten GmbH & Co. KG team by purchasing our care bed. With your choice of a KayserBetten care bed you receive a care pro- duct of high functionality and the highest level of safety.
  • Page 6: Warranty

    Instruction manual for care bed „Ida 1.0“ Warranty KayserBetten GmbH & Co. KG provides a warranty on new equip- ment and components purchased in the European Union if manuf- acturing defects and/or material faults are detected within 24 months after purchase.
  • Page 7: Definition Of Terms

    Instruction manual for care bed „Ida 1.0“ Please note The “Please note” sign indicates potential damage to property. Note Helpful tips. 1. Instructions that need to be followed in a particular order are numbered accordingly (1., 2., 3., etc.). ‹ Instructions without any specific order are marked by a diamond symbol.
  • Page 8: Safety

    (railing) and lock all electronic functions. ‹ Do not carry out any technical modifications or add extra parts without approval of KayserBetten GmbH Co. KG. ‡ DANGER! Strangulation through cables and hoses ‹...
  • Page 9: Emc Warning Notice

    Instruction manual for care bed „Ida 1.0“ EMC warning notice Note For general information on electromagnetic compatibility see chapter 19 („General information on electromagnetic compatibility“). Personnel qualifications According to the German Medical Devices Operator Ordinance (MPBetreibV, §4) the care bed may only be assembled, operated, maintained and repaired by persons who have completed required training or have the necessary knowledge and experience.
  • Page 10: German Medical Devices Operator Ordi- Nance (Mpbetreibv)

    Instruction manual for care bed „Ida 1.0“ German Medical Devices Operator Ordinance (MPBe- treibV) The care bed is subject to the German Medical Devices Operator Ordinance (MPBetreibV). Please note especially the following aspects of the German Medical Devices Operator Ordinance: – Operator’s obligations (MPBetreibV, §3) –...
  • Page 11: Application Parts

    Max. 480W, IP66 / IP24 Max. T_on: 2 min, Min. T_off: 18 min. = 150 kg = 170 kg Importeur: KayserBetten GmbH & Co. KG Rieper Straße 12, 29683 Bad Fallingbostel, Germany Tel. +49 5163 6595, www.kayserbetten.de Position Meaning Manufacturer...
  • Page 12: Symbol - Electric Components

    Instruction manual for care bed „Ida 1.0“ KayserBetten GmbH & Co. KG Tel. +49 5163 6595 Therapieauflage Serial number label with UDI Data-Matrix Code for accessories (e. g. therapy mat) Symbol - electric components The RoHS directive 2011/65/EU restricts the use of certain hazardous substances in electrical and electronic equipment, e.
  • Page 13: Symbols - Packaging

    Instruction manual for care bed „Ida 1.0“ Protection class II / protective insulation, no ground conductor Galvanic isolation e. g.: protection against electromagnetic distur- bance, two separate circuits AC_DC side Symbol for Limoss power connector TÜV type approved, consumer protection, production monitoring TÜV Rheinland: North America Group Protection class II / safety extra-low voltage C-tick compliance mark (electromagnetic compatibility) for standards...
  • Page 14: Scope Of Delivery, Setup And Functions

    Instruction manual for care bed „Ida 1.0“ Scope of delivery, setup and functions Scope of delivery Position Quantity Description sideframe connecting frame 150 mm folding-sliding doors (double) or UK-doors insert frame, mains plug and handswitch brief instructions instruction manual...
  • Page 15 Instruction manual for care bed „Ida 1.0“ Position Quantity Description grub screws M 8 x 95 mm grub screws M 8 x 65 mm cross bolts brass caps allen key cable hanger hook screws 4,5 x 45 mm...
  • Page 16: Setup And Functions

    Instruction manual for care bed „Ida 1.0“ Setup and functions Operate the adjustment mechanism of the care bed with the hand switch. Possible adjustments: – Height of the head section – Height of the foot section – The height of the head section –...
  • Page 17: Transport And Storage

    Instruction manual for care bed „Ida 1.0“ Transport and storage Transporting and storing the care bed ‡ CAUTION! Heavy objects. Risk of injury. ‹ Always transport the care bed with two persons. Please note The service life of care beds for domestic use is approx. five (5) years. Frequent transporting, assembling/disassembling and moving reduces the service life of the care bed.
  • Page 18: Assembly

    Instruction manual for care bed „Ida 1.0“ Assembly Personnel qualifications The bed shall only be assembled by an authorised technician accor- ding to the information provided in this instruction manual. The assembly must be carried out by two people. Specific safety instructions ‡ CAUTION! Cables and parts laying around can create tripping hazards. Risk of injury.
  • Page 19: Mounting Grub Screws

    Instruction manual for care bed „Ida 1.0“ Mounting grub screws ‡ CAUTION! Adjustable folding-sliding doors. Risk of crushing. ‹ Keep the folding-sliding doors closed while assembling the grub screws and ensure that no body parts get trapped. ‡ CAUTION! Protruding parts. Risk of injury. ‹...
  • Page 20: Mounting Connecting Frame

    Instruction manual for care bed „Ida 1.0“ 4. Insert the grub screw (pos. 27) into the grub screw hole (pos. 46). 5. Screw the grub screw (pos. 25) into the cross bolt by one turn. Do not screw the grub screw all the way into the cross bolt. 6.
  • Page 21: Mounting Rear Railing And Connecting Frame

    Instruction manual for care bed „Ida 1.0“ Mounting rear railing and connecting frame 1. Set up the second side frame (pos. 13) so that both connecting frames can be mounted to it. Secure the joint by loosely screwing on the brass caps (pos. 31). 2. First hand-tighten all brass caps on one side (pos. 31) to avoid tilting.
  • Page 22: Place And Secure Insert Frame

    Instruction manual for care bed „Ida 1.0“ Place and secure insert frame 1. Place insert frame (pos. 16) onto the support bars of the connec- ting frames (pos. 18). 2. Ensure the head and foot sections are positioned accordingly (KR2). 3. Remove the cable ties from the insert frame. 4.
  • Page 23: Mounting Door Locking Mechanism

    Instruction manual for care bed „Ida 1.0“ 5. Open the assembled door (see chapter “Opening/closing folding- sliding doors/UK-Doors”). 6. Mount the other door. Proceed as described above for the first door. 7. Close the assembled doors (see chapter “Opening/closing folding- sliding doors/UK-Doors”).
  • Page 24: Initial Set Up

    Instruction manual for care bed „Ida 1.0“ Initial set up Personnel qualifications The bed shall only be assembled by an authorised technician accor- ding to the information provided in this instruction manual. The assembly must be carried out by two people. Disinfecting care bed ‹ Clean and disinfect the care bed before initial set up (see chapter “Cleaning care bed”).
  • Page 25: Connect Electric Components

    Instruction manual for care bed „Ida 1.0“ Connect electric components Position Function 47 hand switch 48 height adjustment 49 power supply cable 50 emergency release of head section Connect the cables to the adjustment mechanism as shown in the figure. The adjustment mechanism is located on the bottom of the insert frame.
  • Page 26: Bed Delivery

    Instruction manual for care bed „Ida 1.0“ Bed delivery Upon delivery of the care bed the operator or the person delegated by the operator has to be instructed based on this instruction manual by the manufacturer or an authorised person (technician). ‹...
  • Page 27 Instruction manual for care bed „Ida 1.0“ ‡ WARNING! Moving parts. Risk of crushing. ‹ Close supervision of persons, animals and objects nearby is necessa- ry when operating the care bed. ‹ Ensure that feet or hands of any person are not placed on the metal stands of the side frames.
  • Page 28: Normal Use

    Instruction manual for care bed „Ida 1.0“ Normal use If the patient has to lie in the care bed unattended: 1. Close the folding-sliding doors (see chapter “Opening/closing fol- ding-sliding doors/UK-doors”) and close the door locking mecha- nism (see chapter “Opening/closing door locking mechanism”). 2.
  • Page 29: Open/Closing Folding-Sliding Doors

    Instruction manual for care bed „Ida 1.0“ Open/closing folding-sliding doors 1. To open the folding-sliding doors, pull down the locking bracket in the middle (pos.51) and hold it back. 2. Pull the upper locking bracket (pos. 52) to the left and let go of the locking bracket in the middle (pos.
  • Page 30: Opening/Closing Uk-Doors

    Instruction manual for care bed „Ida 1.0“ ‡ CAUTION! 6. Adjustable folding-sliding doors. Limbs can get crushed in the folding-sliding doors. Ensure that your limbs do not get crushed. » Close the folding-sliding door and let the locking bracket (pos. 55) snap into place.
  • Page 31: Unlocking/Locking Control Keys - Safe Termination

    Instruction manual for care bed „Ida 1.0“ ‡ CAUTION! 8. Adjustable UK-doors. Limbs can get crushed in the UK-doors. Ensure that your limbs do not get crushed. » Close the outer UK-door and let the locking bracket (pos. 53) snap into place. »...
  • Page 32: Adjusting Head Section

    Instruction manual for care bed „Ida 1.0“ Adjusting head section ‡ WARNING! Risk of injury from open folding-sliding doors/ lowering rails ‹ Close the folding-sliding doors before adjusting the head section. ‡ CAUTION! Risk of injury from crushing or improper positioning. ‹ Moving parts. Risk of crushing. Ensure that no limbs get crushed between the head section and the rest of the care bed.
  • Page 33: Adjusting Foot Section

    Instruction manual for care bed „Ida 1.0“ Adjusting foot section ‡ WARNING! Risk of injury from open folding-sliding doors/ lowering rails ‹ Close the folding-sliding doors before adjusting the foot section. ‡ CAUTION! Risk of injury from crushing or improper positioning. ‹ Moving parts. Risk of crushing. Ensure that no limbs get crushed between the foot section and the rest of the care bed.
  • Page 34: Adjusting Head And Foot Section

    Instruction manual for care bed „Ida 1.0“ Adjusting head and foot section ‡ WARNING! Risk of injury from open folding-sliding doors/ lowering rails ‹ Close the folding-sliding doors before adjusting the head and foot section. ‡ CAUTION! Risk of injury from crushing or improper positioning. ‹ Moving parts. Risk of crushing. Ensure that no limbs get crushed between the head and foot section and the rest of the care bed.
  • Page 35: Transferring Into/Out Of Bed

    Instruction manual for care bed „Ida 1.0“ ‡ WARNING! Risk of injury from open folding-sliding doors/ lowering rails ‹ Close the folding-sliding doors before adjusting the head and foot section. ‡ WARNING! Pay attention to the position of the sleeping platform while adjusting it.
  • Page 36: Cleaning

    ‹ Dermatologically tested household cleaning agents that do not contain ammonium chloride and abrasives ‹ Disinfecting agents according to the DGHM (German Society for Hygiene and Microbiology) list dated 04 February 2002. You can find a list of approved disinfecting agents in the download section at www.kayserbetten.eu.
  • Page 37: Cleaning Care Bed

    Instruction manual for care bed „Ida 1.0“ Cleaning care bed Please note Inappropriate cleaning agents. Property damage. ‹ Do not use any solvents or scouring agents. 1. Pull the mains plug. 2. Wipe the care bed with a damp cloth. Ensure that no moisture enters any electric components.
  • Page 38: Rouble Shooting Guide

    Instruction manual for care bed „Ida 1.0“ ‹ Only have a technician perform the maintenance procedure. The- refore please contact the manufacturer for assistance (see chapter “Manufacturer”). ‹ No persons are allowed in the care bed during maintenance and cleaning work on the care bed or on parts of the care bed. (* only for electrically adjustable care beds) 11 Trouble shooting guide Trouble shooting guide...
  • Page 39: Isassembly

    Instruction manual for care bed „Ida 1.0“ 13 Disassembly ..‡ CAUTION! Reckless use of necessary tools such as screw drivers, cordless drills etc. can cause hand injuries. Please note The service life of care beds for domestic use is approx. five (5) years. Frequent transporting, assembling/disassembling and moving reduces the service life of the care bed.
  • Page 40: Isposal

    Instruction manual for care bed „Ida 1.0“ 11. Now secure the side frame with the help of another person and remove the brass caps from the second connecting frame. 12. Remove the second connecting frame. 14 Disposal ‹ Disassemble the care bed and dispose of it in an environmentally friendly manner.
  • Page 41: Accessories Recommended

    16 Accessories ‡ WARNING! Risk of injury - Do not use accessories other than those authorized by KayserBetten. Using a thicker mattress can for example result in ina- dequate protection of side rails (see chapter 18 “Technical data”). Please note Only the following accessories may be used. All accessories come with maintenance and care instructions.
  • Page 42: Pare Parts List

    Instruction manual for care bed „Ida 1.0“ 17 Spare parts list locking brackets drive mechanism for sleeping platform drive mechanism for height adjustment hand switch mains plug Allen key brass caps threaded rod cross bolts 18 Technical data Technical data Total height 167 cm Total length 192 cm / 222 cm (170x90 cm/200x90 cm)
  • Page 43: Electrical Data

    Instruction manual for care bed „Ida 1.0“ Base of sleeping platform wooden slats Safe lifter load 80 kg Weight side frame 43 kg per side Weight door unit 12 kg per door Weight rear railing 18 kg Weight connecting frame 6 kg Weight sleeping platform 18 kg...
  • Page 44: Classification

    Type BF DIN EN 60 601-1 (protection against electric shock) Protection class acc. II (protective insulation) DIN EN 61140 Safety inspection 1 x yearly Service life The expected service life of the KayserBetten care bed, its parts and accessories is 5 years.
  • Page 45: Eneral Information On Electromagnetic Compatibility

    Betten In order to document the safety instructions during initial set up, maintenance and repair make a photocopy of the maintenance record or download the file at www.kayserbetten.eu. Document the inspec- tion and keep this form with your documentation. Maintenance and repair Information on maintenance and repair provided by KayserBetten.
  • Page 48 KayserBetten GmbH & Co. KG Rieper Straße 12 D- 29683 Bad Fallingbostel Telefon: 05163-6595 Telefax: 05163-2076 info@kayserbetten.de www.kayserbetten.de...