Summary of Contents for InSinkErator AQUASAVER AS-101K
Page 1
The Caution signal alerts you to hazards of unsafe practices which, if not avoided, may result in minor personal injury or property damage. Please be certain that the person who installs or uses this appliance carefully reads and understands the Safety Instructions contained in this manual. www.insinkerator.com/foodservice AquaSaver Installation Manual ®...
The warranty includes parts and labor, provided the service is performed by an InSinkErator Factory Authorized Service Center. This warranty does not apply if failure is due to: faulty or improper electrical installation, faulty or improper plumbing installation, product abuse or misuse, or accidental damage.
INTRODUCTION The AS-101K Control Center is UL ® for use with InSinkErator Foodservice Disposers. See Table 1 for approved disposer and control center combinations. The control center operates the disposer and control center combinations. Its main functions are: • To start and stop the disposer.
Mounting the Control Center/Plumbing Connections MOUNTING THE CONTROL CENTER Use the flanges at the back of the control center enclosure and only mount panel in the upright vertical position (door hinge is on the left). See Figure 1. Locate control center within sight of disposer per local codes.
M1/M3 24V Water Solenoid 1 GPM Flow Control 24V Water Solenoid 7 GPM Flow Control Pre-wired in panel to contactors Neutral Control Center Connection To Power Supply Power Supply Panel Ground Lug Figure 3. Incoming 120 V Single Phase Line Power 24V Water Solenoid 1 GPM Flow Control 24V Water Solenoid...
ELECTRIC SHOCK • Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or circuit tester to ensure that power is off. • All installation work must conform to local plumbing and electrical codes. •...
Operating Instructions/Aqua-Saver Adjustment OPERATING INSTRUCTIONS TO START 1. Check to ensure disposer is free of foreign objects. 2. Ensure power is on. 3. Push start button. Disposer motor will run and water will flow into the disposer. 4. Water flow will decrease to 1 GPM approximately 30 seconds after intitial start-up if no load is present in disposer.
PERSONAL INJURY • Allow only trained personnel to operate disposer. • Use baffles and guarding to avoid splashing and ejection of materials. • Do not put fingers or hands into the disposer. • When attempting to remove objects from a disposer, use long-handled tongs or pliers.
1-phase 1/2 to 2 HP STOP STOP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support. AS-101K-1 Wiring Diagram • Ensure that the control center voltage and phase match the disposer motor and electrical supply.
STOP STOP START START Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support. AS-101K-2 Wiring Diagram • Ensure that the control center voltage and phase match the disposer motor and electrical supply.
208/230 V 3-phase 1/2 to 10 HP STOP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support. AS-101K-3 Wiring Diagram • Ensure that the control center voltage and phase match the disposer motor and electrical supply.
BOARD STOP STOP START START Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support. AS-101K-4 Wiring Diagram • Ensure that the control center voltage and phase match the disposer motor and electrical supply.